User Manual Bathtub ELYSEE Indra Table of contents Preface Operating precautions Table of contents 1. General arrangement drawing 2. Dimensions 3. Options et accessories 4. Technical specifications DESCRIPTIF COMPLIANCE SAFETY INSTRUCTIONS AND WARNINGS COMMISSIONING AND INSTRUCTIONS FOR USE 5. Operating instructions 5.1.
Page 3
Bathtub ELYSEE Indra Preface Thank you for trusting and choosing the products Elysee Concept. Before using your bathtub, please read entirely this manual. The information contained in this manual is essential to the proper operation and maintenance of the equipment. It will help you to best protect your investment and guarantee you a perfect operation of your equipment.
User Manual Bathtub ELYSEE Indra 1. General arrangement drawing Elysée INDRA Starting of hydromassage * 1 push = continuous jet (red LED on) 2 pushes = al terna ti ve jet (red LED on-lighting) 3 pushes = s top (LED off)
50 mm draining tap COMPLIANCE Your Elysée Indra bathtub, equipped with a lifting table (height-adjustable frame), has a type IIA certificate of conformity and is CE marked. This means that its design and construction comply with the MACHINES directive of the EEC Council SAFETY INSTRUCTIONS AND WARNINGS ...
Annual bathtub maintenance will be conducted by an approved technician 5. Operating instructions The ELYSEE Indra bathtub equipped with the lift table is a bathtub that offers unique comfort for It’s destined for washing people. The lift table can only be used in patients and caregivers.
Press the rise pushbutton (upper A button) located on the bath shelf next to the taps of the ELYSEE Indra bathtub. The lift table continues to rise as long as the push-button pressure is maintained. The electric rise control of the lift table will automatically stop the rise as soon as the cylinders arrive at the end of the race.
User Manual Bathtub ELYSEE Indra 5.2. Bath setup 5.2.1. Locking of draining trap Refer to Figure II Turn the overflow cap cover to seal the draining tap before turning the water on. FIGURE II : overflow cap cover and draining tap 5.2.2.
The bathtub Elysée Indra offers full access all around the bath, as far as the space around the bathtub allows it. The entire periphery of the lift table has a clearance to allow the feet to be placed without the risk of pinching.
After a bath containing bath additives, the bathtub should be rinsed with clear water. Once a year, it is recommended that you maintain your Elysee bath by a qualified technician. The valves used for KIWA certification must be replaced every 10 years (as per WB1.4G Standard –...
Turn the overflow cap cover to seal the draining tap. Turn on the water at appropriate t° -Install the patient in the ELYSEE Indra bathtub Adjust the height of the tub to obtain an ergonomic working position. turn the overflow cap cover on the right to unseal the draining tap and let the...
User Manual Bathtub ELYSEE Indra 9. Technical settings instruction Once the ELYSEE Indra bathtub and lift table are set in position and height, no adjustment is required. 10. Recommendation If your Elysée Indra bath is equipped with natural therapies or external disinfection devices, please refer to the Elysée Ad-hoc instructions provided with the bath.
Page 15
User Manual Bathtub ELYSEE Indra jeudi 7 février 2019 - 15...
Page 16
User Manual Bathtub ELYSEE Indra jeudi 7 février 2019 - 16...
Page 17
User Manual Bathtub ELYSEE Indra IN CAS OF FAILURE – instruction for technicians only PROBLEMS SOLUTIONS Pressure failure Clean filter Hot water failure Replace cartridge Control filter Lift Do not rise Check power supply Check connection in the electrical box...