  • Page 1 MM-KKE-M-C-U Measuring microscope Operating and Maintenance Instructions English (translation of original instructions) Document no.: 3239239b...
  • Page 2: Trademarks

    HYDAC Filter Systems GmbH all rights reserved All rights reserved. This manual may not be reproduced in part or whole without the express written consent of HYDAC FILTER SYSTEMS GMBH. Contraventions are liable to compensation. Exclusion of Liability We have made every endeavor to ensure the accuracy of the contents of this document.
  • Page 3: Table Of Contents

    Cleaning / maintaining the microscope ..............24 Replacing the bulb on the microscope..............25 Replacing the illuminator bulb................27 Disposing of your microscope................28 Model Code ......................29 Technical Data ......................30 HYDAC FILTER SYSTEMS GMBH Page 3/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 4: Preface

    HYDAC FILTER SYSTEMS GMBH Technische Dokumentation Postfach 12 51 66273 Sulzbach / Saar Germany We look forward to receiving your input. “Putting experience into practice” HYDAC FILTER SYSTEMS GMBH Page 4/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 5: Technical Support

    After modification or repair work that affects the safety of the product has been carried out on components, the product may not be returned to operation until it has been checked and released by a HYDAC technician. Please notify us immediately of any modifications made to the product whether by you or a third party.
  • Page 6: Using The Documentation

    The documentation number with its index enables you to order another copy of the operating and maintenance instructions. The index is incremented every time the manual is revised or changed. HYDAC FILTER SYSTEMS GMBH Page 6/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 7: Safety Information And Instructions

    Our General Terms and Conditions apply. Any and all warranty and liability claims for personal injuries and damage to property shall be excluded in the event they are attributable to one or more of the following causes. HYDAC FILTER SYSTEMS GMBH Page 7/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 8: Explanation Of Symbols And Warnings, Etc

    Improper Use Never look into the sun /sunlight using the microscope. This may damage your eyesight. HYDAC FILTER SYSTEMS GMBH Page 8/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 9: Transporting The Microscope

    ► Store the microscope in a clean and dry location in its closed transport case and in a horizontal or vertical position. The microscope must not be exposed to any shaking or vibration. HYDAC FILTER SYSTEMS GMBH Page 9/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 10: Checking The Scope Of Delivery

    WinTV USB (external TV card) including USB connection cable, L=1.8 m CD-ROM containing the software for on-screen image viewing Transport case Replacement bulb, replacement fuse, ground glass plate (transparent / blue-tinted) HYDAC FILTER SYSTEMS GMBH Page 10/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 11: Microscope Features

    The following system requirements must be fulfilled for the installation: Operating system: Windows 98, ME, 2000, XP, VISTA or 7 Hardware: Pentium 800 MHz Free USB port 2.0 CD-ROM drive HYDAC FILTER SYSTEMS GMBH Page 11/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 12: Components On The Microscope

    Switch-over between binocular / camera eyepiece Power connection Power switch for internal lighting Illumination intensity adjustment dial for internal lighting Adjustment lever for limiting the height setting of the x/y mechanical stage HYDAC FILTER SYSTEMS GMBH Page 12/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 13 "swiveled" into place. Specimen stage The specimen stage generally consists of a square including x/y shaped plate featuring a hole or slit in the center HYDAC FILTER SYSTEMS GMBH Page 13/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 14 A light source is needed to illuminate a specimen, source the light being projected through the condenser into the specimen and then projected by this in turn into the objective lens and the eyepiece. The HYDAC FILTER SYSTEMS GMBH Page 14/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 15 Ground glass plate Serves to diffuse light and is slid into a specially constructed slit between the lamp and collector. It enables light to be distributed evenly without colored fringes. HYDAC FILTER SYSTEMS GMBH Page 15/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 16: Installing The Microscope

    The microscope has a condenser and a source of lighting for transmitted light mode. This light source is normally not suitable for examining filter membranes. 4. The assembly of your microscope is complete. HYDAC FILTER SYSTEMS GMBH Page 16/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 17: Assembling The Illuminator (Cold Light Source)

    Screw the setscrew in and tighten it gently. Plug the connector cable into the Fehler! Es ist nicht möglich, illuminator. durch die Bearbeitung von Feldfunktionen Objekte zu erstellen. HYDAC FILTER SYSTEMS GMBH Page 17/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 18 The illuminator has a fan to cool the lamp. This fan makes a small amount of noise when in operation. The illuminator is now ready for use. HYDAC FILTER SYSTEMS GMBH Page 18/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 19: Installing And Setting The Camera

    IN jack of the camera using the right plug, and then plug the power plug into the wall outlet. The camera’s POWER indicator light should now light up and stay lit.. HYDAC FILTER SYSTEMS GMBH Page 19/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 20: Installing The Image Processing Software

    PC and ready for operation. Installing the image processing software To install the image processing software, read the installation instructions which come with the microscope or the camera. HYDAC FILTER SYSTEMS GMBH Page 20/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 21: Operating The Microscope

    This has to be individually adjusted for everyone using the microscope. The x/y mechanical stage provides for adjustment in an X and Y direction. HYDAC FILTER SYSTEMS GMBH Page 21/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 22: Performing A Measurement

    The scale can also be found by referring to the type plate affixed to the back of the stand or on the camera. HYDAC FILTER SYSTEMS GMBH Page 22/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 23: Evaluating A Filter Membrane / Sample

    10 µm ~ 1.2 12 µm 10 : 1 10 µm 20 µm 20 : 1 5 µm ~ 1.2 6 µm 20 : 1 5 µm 10 µm HYDAC FILTER SYSTEMS GMBH Page 23/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 24: Performing Maintenance

    The optical components are to be cleaned using a clean, dry lint-free linen cloth or lens cleaning paper. Remove any stubborn coating with extreme care using a cloth soaked in alcohol. HYDAC FILTER SYSTEMS GMBH Page 24/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 25: Replacing The Bulb On The Microscope

    [B] Knurled pin for adjusting the lamp.. [C] Temperature fuse plug for lamp. 5. Undo the knurled pin [A] by turning it in a counterclockwise direction and open the lamp flap. HYDAC FILTER SYSTEMS GMBH Page 25/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 26 Fingerprints burn in during operation. Plug the lamp into the base. Replacement bulb: Type: 10W 6V OSRAM no. 644410 S 8. The bulb replacement is complete.. HYDAC FILTER SYSTEMS GMBH Page 26/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 27: Replacing The Illuminator Bulb

    4. Mount the housing lid and screw in the 4 Phillips head screws again. Plug in the power plug and switch on the illuminator. 5. The bulb replacement is complete.. HYDAC FILTER SYSTEMS GMBH Page 27/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 28: Disposing Of Your Microscope

    After disassembling the unit and separating the various materials, reuse them or dispose of them properly in accordance with local regulations. HYDAC FILTER SYSTEMS GMBH Page 28/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 29: Model Code

    = 230 V AC / 50 Hz / 1 Phase (Europe) = 100 V AC / 50 Hz / 1 Phase (Japan) Accessories = Cold light lighting = Without Supply voltage = CCD camera with USB port HYDAC FILTER SYSTEMS GMBH Page 29/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 30: Technical Data

    24 V DC, ± 20%, residual ripple ≤ 10% Power consumption / electricity 100 W max. / 4 A max. IP class IP 50 (open, in operation) IP 67 (closed) Protection class III (safety extra-low voltage) HYDAC FILTER SYSTEMS GMBH Page 30/32 BeWa MM-KKE-M-C-U 3239239b en-us 2011-10-10.doc 2011-09-27...
  • Page 32 HYDAC FILTER SYSTEMS GMBH Industriegebiet Postfach 1251 66280 Sulzbach/Saar 66273 Sulzbach/Saar Germany Germany Phone: +49 (0) 6897 509 01 Central Fax: +49 (0) 6897 509 846 (Technical Department) Fax: +49 (0) 6897 509 577 (Sales Department) Internet: www.hydac.com Email: filtersystems@hydac.com...