Advertisement

Technical Instructions
LGRM-E
Automated Logic Corporation • 1150 Roberts Blvd. • Kennesaw, GA 30144 • 770/429-3000 • 770/429-3001 Fax •
www.automatedlogic.com • Copyright 2002 Automated Logic Corporation. All rights reserved. Automated Logic, the
Automated Logic logo, SuperVision, Eikon, and Alert are registered trademarks of Automated Logic Corporation.
InterOp is a trademark of Automated Logic Corporation. BACnet
and product names are trademarked by their respective companies.
®
is a registered trademark of ASHRAE. All other brand

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LGRM-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Automated Logic LGRM-E

  • Page 1: Table Of Contents

    Protection 10 Production Date 10 Automated Logic Corporation • 1150 Roberts Blvd. • Kennesaw, GA 30144 • 770/429-3000 • 770/429-3001 Fax • www.automatedlogic.com • Copyright 2002 Automated Logic Corporation. All rights reserved. Automated Logic, the Automated Logic logo, SuperVision, Eikon, and Alert are registered trademarks of Automated Logic Corporation.
  • Page 2: Using The Lgrm-E

    Using the LGRM-E The LGRM-E is part of the Gateway family and communicate with the LGRM-E over TCP/IP provides communication between a as discussed in the document TCP/IP Setup for workstation and a control module network Windows 95/NT and SVW 2.6 (Part number (CMnet) consisting of fewer than 100 LGTCPIP).
  • Page 3: Specifications

    Mounting The LGRM-E is rack-mounted using four holes on the faceplate (see Figure 1 on page 2). If a rack is not available, the LGRM-E can be mounted with mounting brackets. The LGRM-E is designed to be mounted inside the building. All warranties are void if Figure 3.
  • Page 4: Ip Addressing

    Before setting or changing the address, make Default mode Use the following procedure to set the IP sure the LGRM-E’s power is off. The LGRM-E address when using the Default mode: only reads the address when the module is turned on. After changing the address, you 1.
  • Page 5: Wiring

    5. Establish communication with the Figure 4) to the power connector on the LGRM-E through SuperVision using one of back of the LGRM-E (see Figure 5 on page the connection types in Table 1. 3. Plug the power adaptor into an outlet.
  • Page 6: Initializing The Lgrm-E

    CMnet connection labeled on the CMnet. Net - and Net + on the LGRM-E (see Figure • If the workstation is connected to the 1 on page 2). Also connect the Shield if on LGRM-E by modem, the workstation an ARC156 CMnet.
  • Page 7: Transferring Memory

    APT (see Figure 6 on page 8). The LGRM-E uses the LEM module driver. No other FBs can be added to the LGRM-E. If any Connecting Using the Console Ports problems occur during this procedure, Use the wiring diagrams in Figure 7 on page 8 contact Technical Support at (770) 429-3002.
  • Page 8 ** N e e d e d o n ly if h a rd wa re h a n d s h a kin g is u se d *R I 9 2 2 R I* Figure 7. Wiring Diagrams Revised 11/6/02 • LGRM-E © 2002 Automated Logic Corporation...
  • Page 9: Formatting The Module

    Present? Type Access Port Error - indicates an error has been detected. ARC156 Direct Connect CMnet transmit - indicates that the LGRM-E is ARC156 Direct Network transmitting data over the CMnet. legacy Direct Network CMnet receive - indicates that the LGRM-E is receiving data from the CMnet.
  • Page 10: Protection

    Port is receiving data. normal. Production Date LGnet receive - indicates the LGRM-E is receiving data from the CMnet. To determine when a module was manufactured, check the module status LGnet transmit - indicates the LGRM-E is report in SuperVision.

Table of Contents