AutomationDirect IronHorse GSDA-DP-S User Manual

Signal conditioner/generator

Advertisement

Quick Links

GSDA-DP-S S
C
/G
U
M
iGnAl
onDitioner
enerAtor
Ser
AnUAl
U
M
n
: GsDa-DP-s_UMP
ser
anUal
UMber
IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IronHorse GSDA-DP-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AutomationDirect IronHorse GSDA-DP-S

  • Page 1 ™ GSDA-DP-S S iGnAl onDitioner enerAtor AnUAl : GsDa-DP-s_UMP anUal UMber IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 1...
  • Page 2: Warning

    770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation.
  • Page 3: Table Of Contents

    GSDA-DP-S User Manual Overview � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 IronHorse GSDA-DP-S General Information� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 GSDA-DP-S Installation �...
  • Page 4: Gsda-Dp-S User Manual Overview

    All information contained in this manual is intended to be correct. However, information and data in this manual are subject to change without notice. AutomationDirect (ADC) makes no warranty of any kind with regard to this information or data. Further, ADC is not responsible for any omissions or errors or consequential damage caused by the user of the product.
  • Page 5 AutomationDirect, Inc. (ADC) warrants its products to be free from defects in material and workmanship. The exclusive remedy for this warranty is ADC factory replacement of any part or parts of such product which shall within 12 months after delivery to the purchaser be returned to ADC factory with all transportation charges prepaid and which ADC determines to its satisfaction to be defective.
  • Page 6: Gsda-Dp-S Installation

    4.00 [101.6] 4.00 3.62 [101.6] [91.9] GSDA-DP-S 0.885 [22.5] ENTER HOUSING DEPTH 1.77 [45.0] 4.625 [117.5] .140 PANEL CUT-OUT [3.6] 5.00 [127.0] 2.289 1.656 [58.1] [42.1] 4.625 [117.5] IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 6...
  • Page 7 IN1 - Contact input for user configurable actions such as specified output, and P3-9 set point lock� IN2 - Contact input for user configurable actions such as specified output, and P3-10 set point lock� P3-11 P3-12 IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 7...
  • Page 8: Gsda-Dp-S Operation

    Run mode is the default display of the unit when power is applied. The display shows the target value in the appropriate user-defined format. The Up and Down buttons increase or decrease the displayed target value until either the display minimum or display maximum limit is reached. IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 8...
  • Page 9: Device Configuration

    The user should evaluate what their system will be doing during this adjustment to prevent any harmful results. ODe Of PeratiOn There are three Modes of Operation for the GSDA-DP-S, established by the JP1, JP3, and JP4 jumper settings: IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 9...
  • Page 10 Current Scale Voltage Voltage Scale Voltage Current Scale Generate Voltage Generate Current Scale = 2 Allow Change = P/ EN position Gen = 1 Inhibit Change = ‘COM’ position IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 10...
  • Page 11: Software Parameters

    6–Output 100% when IN2 High 7–Lock Set Point when IN2 High (Eng� IN2 Setpoint -9999–9999 Units) Parameter Memory Commands 0–Do Nothing and Exit Restore Settings to Factory Default 5–Restore Factory Defaults IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 11...
  • Page 12 Display Maximum is reached� The displayed value will initially scroll at a slow rate and increase in speed until the maximum scroll rate is achieved� The initial scroll rate is specified using parameter 16� IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 12...
  • Page 13 850 will configure the GSDA-DP-S to output 85�0% when the user adjusts the display value to equal the display maximum, parameter 21� See parameters 20 - 21and the application examples for additional information� IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 13...
  • Page 14 When the S1 configuration, parameter 30, is set to one of the setpoint ( jog) modes (modes 3 or 4), this parameter defines the IN1 Setpoint jog setpoint in display units� This parameter is always set in display units� IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 14...
  • Page 15 This can also be achieved by applying power to the Restore Settings to Factory Default unit with both the Enter and Down buttons depressed� The programming jumper must be in the “On” position for this method to function� IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 15...
  • Page 16: Troubleshooting

    If JP1, JP3, or JP4 are missing or on one pin, then it will have either minimal value output or none at all depending on output type configuration� Please recheck all settings and jumper configurations� Literature Number: LT184 Drawing Number: A-5-4168B IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019 Page 16...