  • Page 1 Coolant Purification Systems Ultra 90 INSTRUCTION MANUAL Model: Ultra 90 Serial No. Manufacture Date: Revision: E September 2016...
  • Page 2 Unit Foot Print & Layout Description of each components...
  • Page 3 • Installation of this system on any machine other than those listed, voids any and all intended warranties and liabilities by Green Eco Pro Co. TOOLS REQUIRED: The installation of this machine can be accomplished with basic machine service tools...
  • Page 4 Installation Guide – Page 1 1. Please verify all peripheral accessories. Hose Clamps 1” coolant return hose Main unit Filter Wrench Filter element Coolant Float Inlet unit 2. An instruction of installation procedure 1.1Install the filter element, be sure to retain the O-ring...
  • Page 5 Installation Guide – Page 2 2.1 Connect the 1” Coolant return 3.1 Connect the Coolant Inlet hose to the hose to Coolant Outlet port by Coolant Inlet port using small hose clamp using the large hose clamp. 4. 1 Connect Air supply hose 5.
  • Page 6 The coolant outlet hose must be kept below the coolant outlet port, as illustrated above. 9. 1 Adjust the machine leveling feet, utilizing the leveling gauge, Refer to the middle diagram above 10. 1 For Ultra 90, turn the Coolant volume switch to On position,...
  • Page 7 Installation Guide – Page 4 11. 1 Connect the drain hose to a recycle tank. A tank is not supplied in the kit. Be sure the oil outlet valve is in the On position 12. In order to obtain the best performance, this coolant purification unit must be installed within 3 Feet from the CNC machine.
  • Page 8 Operating Guide & Safety – Page 1 1. Coolant Volume Adjustment 1.1 With switch in the Off position, connect the air supply hose. Check the incoming air pressure by reading the gauge. Factory default setting at 35 P.S.I. If the actual air pressure is above/below the factory recommended value, adjust accordingly.
  • Page 9 Operating Guide & Safety – Page 2 Filter Indicator Under normal condition/operation the filter indicator will read between the Green to Yellow zone. When processing a higher viscosity of way lube oil, the filter indicator may reach the Red zone. Please verify the operation of the float tubes. If the filter indicator stays in red zone, check the condition of float tube hose for obstruction.
  • Page 10 Maintenance Guide – Page 1 1. Clean the Filter element 1. 1 Be sure to turn off the unit by disconnecting the Air supply hose. 2.1 Use the filter wrench to remove the filter canister, turning the filter as indicated . 3.1 Clean the filter element and the canister by applying high pressure air, as illustrated above.
  • Page 11 Maintenance Guide – Page 2 3. The location of Oil Lubrication & Filtration 1. 1 Check the level of oil lube on the air regulator unit by removing the top cover, if required please refill with O.E.M recommended oil -TURBINE OIL ISO VG32. 2.
  • Page 12 Faulty Recovery Procedure – Page 1 The location of Pump Reset button 1. In the event of pump clogging, such as sludge, temporarily set the air pressure higher and reset the pump. See the illustration above. Once the fault recovery is completed, readjust the air pressure to recommended value of 35 P.S.I.
  • Page 13 Self inspection sheet-Page 1 Maintenance Maintain &Recovery Procedure Weekly Monthly quaterly Check Items Clean filter element, Apply high pressure purified air thru or clean it with ● canister and soap and water O-Ring Float Tube Check if cracks or physical damage have ●...
  • Page 14 Self inspection sheet- Page 2 Maintenance Maintenance & Recovery Procedure Weekly Monthly Quarterly Check Items Check unit ● Clean the exterior of the unit with towel exterior Unit interior Check the ● Clean with towel & exterior window glass Oil recycling clean with towel, replacement is required if cracks ●...
  • Page 15: Warranty Statement

    Green Eco Pro Co. The warranty does not cover for replacements in the event of accidental such as natural disasters or malicious damage or damage caused by misuse of the product.