Measure, Analyze, Control ... be smart I. INTRODUCTION Thank you for purchasing the smart-MAC D105 pulse counter. This device allows you to measure resource consumption by taking into account readings from water, gas, electricity and other meters, equipped with pulse outputs.
Measurement of temperature and Location of device components / or humidity. The device is made in a plastic case designed for installation on a DIN rail. The device allows you to connect a The figure shows the main compo- maximum of 5 temperature sensors nents of the device.
Measure, Analyze, Control ... be smart Device status indicator The device status indicator is located on the front panel. The indicator signals the following device conditions: Indicator Status Device status The indicator flashes quickly search and connect to a wireless network Indicator flashes slowly connection to the device is possible as a wireless access point for initial settings...
III. GETTING STARTED This chapter provides step-by-step instructions for installing, connecting, and setting up the device. The chapter includes the following sections: • Installation and connection to the power supply • Connect to a wireless network • Settings Installation and Connection 2.
Page 7
Measure, Analyze, Control ... be smart Wiring diagram Top contact group 1 GND 2 pulse input 1 3 pulse input 2 4 input temperature sensors 5 analog input 6 +5 V Bottom contact group 7-8 controlled output 9-10 power 220 V A WARNING: Incorrect power connection (220V) can lead to damage to the device.
“smart-MAC” + network connection of the device, configure the connection (your device number). settings by performing the following If the “smart-MAC” + network (your steps: device number) is missing, click the 1. In the «Configuration» section, Reset button on your device. The...
Page 9
Measure, Analyze, Control ... be smart INPUT CONFIGURATION 4. In the «Data Server» section, check the device’s connection to the AND SENSORS: «cloud» server. 1. In the «Counter» section, select the 5. In the «Status» section, look and operation mode of the impus inputs. copy the device ID for yourself.
IV. MQTT SERVICE The device supports data transfer To connect to the server, you need contact output control to fill in the fields “Server address”, using the Message Queue Telemetry “Port” and “Username”. Transport (MQTT) service. The device periodically publishes You can activate the MQTT service data in the format <device number>.
Measure, Analyze, Control ... be smart V. RESET AND RECOVERY FACTORY SETTINGS To restore the factory settings, you the factory settings, the device must use the Reset button. The Reset will reboot and enter the wireless button is located near the top contact access point mode.
VII. CONDITIONS AND NOTIFICATIONS The function of checking data for perform one of the selected actions: compliance with specified conditions send e-mail; relay activation; relay off. allows you to automate the operation Conditions are checked at intervals of of a controlled output or receive noti- 5 seconds.
Page 13
Measure, Analyze, Control ... be smart To activate the condition, you Hysteresis is set only for action - must select the data type, select the sending e-mail. Hysteresis is designed comparison sign «>» or «<», enter to prevent the sending of repeated a value for comparison, select the e-mail messages when the value of required action.
VIII. CONTENTS OF DELIVERY Scope of delivery must comply with the following table № Name Кол-во Energy monitor smart-MAC 105 Temperature sensor DIN rail fastener DIN rail Wall plugs IX. SPECIFICATIONS Key Features and ranges of measured values Pulse input...
VISUALIZATION. The data obtained during the mea- surements are sent to the database on the «cloud server». Access to data is carried out using the smart-MAC Dashboard service. For data visualization and analysis it is necessary: 1. Create your account on the «cloud server», for this, follow the link...