Advertisement

Quick Links

Operation Manual for USB Autoscope Lite
Please read this manual thoroughly before attempting to operate the device.
Contents
1. Purpose.......................................................................................................................................2
2. Technical characteristics of the USB Autoscope Lite.............................................................2
2.1 General...................................................................................................................................2
2.2 Analog oscilloscope mode.....................................................................................................3
2.3 Software.................................................................................................................................3
2.4 Parameters of the USB port's galvanic isolation....................................................................4
2.5 Front panel elements..............................................................................................................5
2.6 Back panel elements..............................................................................................................5
2.7 Ground cord...........................................................................................................................6
3. Preparing the computer for use with the USB Autoscope Lite.............................................7
3.1 Minimum Laptop or PC requirements...................................................................................7
3.2 Installation of the USB Oscilloscope program and utilities..................................................8
3.3 Installation of the device drivers..........................................................................................12
4. Preparing the device for use....................................................................................................13
5. Manufacturer limited warranty.............................................................................................14
6. Troubleshooting........................................................................................................................14
6.1 The device does not turn on.................................................................................................14
6.2 "USB transfer error"............................................................................................................14
http://usbautoscope.eu/
USB Autoscope Lite - Operation Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Usb Autoscope Lite and is the answer not in the manual?

Questions and answers

Summary of Contents for Autoscope Technology Usb Autoscope Lite

  • Page 1: Table Of Contents

    2.5 Front panel elements......................5 2.6 Back panel elements......................5 2.7 Ground cord...........................6 3. Preparing the computer for use with the USB Autoscope Lite..........7 3.1 Minimum Laptop or PC requirements...................7 3.2 Installation of the USB Oscilloscope program and utilities..........8 3.3 Installation of the device drivers..................12 4.
  • Page 2: Purpose

    The USB Autoscope Lite is used for troubleshooting of various electronic vehicle systems, such as ignition and timing system. The USB Autoscope Lite is also very useful for engine mechanical diagnostics. The device is universal in nature and not tied to any particular vehicle system or brand.
  • Page 3: Analog Oscilloscope Mode

    USB Autoscope Lite – Operation Manual 2.2 Analog oscilloscope mode  Number of analog channels – 8  Number of universal analog inputs – 6  Number of inputs for high-voltage – 2 transducers  Number of inputs for the –...
  • Page 4: Parameters Of The Usb Port's Galvanic Isolation

    FAT32 – 4 GB NTFS – 16 TB 2.4 Parameters of the USB port's galvanic isolation USB Autoscope Lite has galvanic isolation of the USB port (device inputs ground <> PC ground)  Galvanic isolation resistance – not less than 10 GΩ...
  • Page 5: Front Panel Elements

    USB Autoscope Lite – Operation Manual 2.5 Front panel elements Front panel of the USB Autoscope Lite. 1…4 Connections for analog inputs 1…4. Input voltage range ± 15 V. 5…6 Connections for analog inputs 5…6. Input voltage range ± 150 V.
  • Page 6: Ground Cord

    USB Autoscope Lite – Operation Manual 2.7 Ground cord Signal measurements on the analog inputs of the USB Autoscope Lite are recommended to perform relatively to the black alligator clip of the ground cord. Therefore, before starting the measurement, the cable must be connected to the back of the device connector (ground) and the black alligator clip must be connected to vehicle ground on the diagnosed vehicle.
  • Page 7: Preparing The Computer For Use With The Usb Autoscope Lite

    USB Autoscope Lite – Operation Manual 3. Preparing the computer for use with the USB Autoscope Lite 3.1 Minimum Laptop or PC requirements  Processor – Pentium II 500 MHz  RAM (random-access memory) – 512 MB  Hard disk drive –...
  • Page 8: Installation Of The Usb Oscilloscope Program And Utilities

    USB Autoscope Lite – Operation Manual 3.2 Installation of the USB Oscilloscope program and utilities  Insert the installation CD disc in the optical disk drive of the computer.  If the notification "Tap to choose what happens with this disk" appears, left-click the message screen.
  • Page 9 USB Autoscope Lite – Operation Manual  If a pop up about unknown publisher of "setup.exe" appears, click "Yes".  You may have to wait while the installer verifies.  In the window "Installer Language", change the installation language if desired.
  • Page 10 USB Autoscope Lite – Operation Manual  In window "Windows Security" activate option "Always trust software from…" then press button "Install".  If the message "Windows can't verify the publisher of this driver software" appears, choose the option "Install this driver software anyway".
  • Page 11 USB Autoscope Lite – Operation Manual  Press the "Finish" button. Now the USB Oscilloscope software is installed completely and drivers are presetting. http://usbautoscope.eu/...
  • Page 12: Installation Of The Device Drivers

    USB Autoscope Lite – Operation Manual 3.3 Installation of the device drivers Connect the device to USB 2.0 12 Mbit/s (Full-SPEED) port of the laptop or PC only after installation of USB Oscilloscope software.  Right after connection of the device to a USB 2.0 12 Mbit/s (Full-SPEED) port the installation of drivers will start automatically.
  • Page 13: Preparing The Device For Use

    The computer must have Microsoft Windows XP SP2 or higher operating system and have the USB Oscilloscope software installed.  Before the measurements, the black alligator clip from the USB Autoscope Lite's ground cord must be connected to vehicle ground on the diagnosed vehicle. The preferred connection point is a vehicle body ground on the diagnosed vehicle.
  • Page 14: Manufacturer Limited Warranty

    The manufacturer guarantees the performance of the USB Autoscope Lite during its warranty period. Warranty period for the main unit USB Autoscope Lite is 24 months from the date of sale. During the warranty period, the manufacturer will at their discretion, replace or repair components that failed due to a manufacturing defect or during normal use.

Table of Contents