NIVELCO NIPRESS P6 Installation And Programming Manual

Programming device

Advertisement

Quick Links

NIPRESS
P6
programming device
Manufacturer:
NIVELCO Process Control Co.
H-1043 Budapest, Dugonics u. 11.
Phone: (36-1) 889-0100
Fax: (36-1) 889-0200
E-mail:
sales
@nivelco.com
www.nivelco.com

Advertisement

Table of Contents
loading

Summary of Contents for NIVELCO NIPRESS P6

  • Page 1 NIPRESS programming device Manufacturer: NIVELCO Process Control Co. H-1043 Budapest, Dugonics u. 11. Phone: (36-1) 889-0100 Fax: (36-1) 889-0200 E-mail: sales @nivelco.com www.nivelco.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION ......................3 PPLICATION 1.1 A ......................3 1.2 A CCESSORIES ......................3 2. INSTALLATION AND WIRING ..................3 2.1 G ENERAL NOTES ......................3 2.2 S TEPS OF INSTALLATION ..................... 3 IRING 2.3 W ........................4 2.4 D IMENSIONS ......................
  • Page 3: Introduction

    1. INTRODUCTION 1.1 A PPLICATION The programming device P6 was developed especially for the configuration of the NIPRESS DK-100 and DK-200 pressure switches on site without a laptop. The programming device has to be connected between supply and the pressure switch. Programming device P6 has a user friendly, closed menu system which can be configurated via two miniature push buttons on the front.
  • Page 4: Wiring

    2.3 W IRING On the top of the device On the end of the cable Wiring diagram Supply + Supply + Contact 1 Contact 2 Supply – Supply – M 12 x 1 (5-pin) male connector M 12 x 1 (5-pin) female connector female connector male connector Male plug on the programming device...
  • Page 5: Dimensions

    2.4 D IMENSIONS Programming device P6 front and side view Programming device P6 view from above jbdp612a0600p_02♦ 5 / 12...
  • Page 6: Programming

    3. PROGRAMMING 3.1 O PERATING AND DISPLAY MODULE Status LED Status LED The device has a green LED for displaying the active contact of set point 1 and a yellow LED Set Point 1 Set Point 2 for displaying the active contact of set point 2. The LEDs will light up when the respective set point has been reached and the contact is active.
  • Page 7: Structure Of The Menu System

    3.3 S TRUCTURE OF THE MENU SYSTEM jbdp612a0600p_02♦ 7 / 12...
  • Page 8: Parameters Description And Programming

    3.4 P ARAMETERS DESCRIPTION AND PROGRAMMING Menu 1 – Read All Via the menu „Read All" all parameters are transferred from the pressure switch into the programming device. This function must be carried out after connection power supply. After switching on the power supply, it is only possibly to execute this function and the function „Load". To execute the „Read All“-function it is required to press both buttons simultaneously.
  • Page 9 Menu 7 - Switch-on point / lowest set point SP 2 Via the menu “Switch-on point / lowest set point” it is possible to define the switch-on point of the pressure switch (contact 2). Setup mode is entered by pressing both buttons simultaneously. You can set the required value by using the buttons “▲“ or “▼“. To complete the setting push the two buttons simultaneously.
  • Page 10 Menu 14 – Switch off delay SP 2 Via the menu “Switch-off delay” it is possible to set the delay time of set point 2. Setup mode is entered by pressing both buttons simultaneously. You can set the required value by using the buttons “▲“ or “▼“.The delay time can be set between 0.01 and 90 seconds. To complete the setting push the two buttons simultaneously.
  • Page 11 Menu 20 – Storage of current configurations Via the menu “Stor” you can store maximally 5 different configurations in the programming device. To file the data on the desired storage space you have to push both buttons simultaneously to select the required storage space. After activating the storage mode in the display appears “St n”...
  • Page 12: Maintenance And Repair

    The instrument does not require regular maintenance. If necessary possible dirt deposited should be cleaned off. All repairs will be carried out at the Manufacturer’s premises. 5. WARRANTY NIVELCO provides warranty of 3 (three) years in compliance with details described in the Warranty Card. jbdp612a0600p_02 September 2017 NIVELCO reserves the right to change technical data without notice.

Table of Contents