5200 Series Master Clock
Wharton
Operating and Installation Instructions
Issue 1.6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for WHARTON 5200 Series

  • Page 1 5200 Series Master Clock Wharton Operating and Installation Instructions Issue 1.6...
  • Page 2 Warranty You can return your unwanted Lithium batteries to the The 5200 series master clock is fully guaranteed, on a return to manufacturer or their agent. works basis, against failure due to faulty parts or workmanship for one year from date of purchase.
  • Page 3: Table Of Contents

    5200 Series Master Clock Operating and Installation Instructions Contents Introduction .............. 4 Installation ..............5 5200 Programming ........... 6 Time Setting Procedure ........... 7 Location Setup ............8 City / Location Table ............9 Synchronisation Setup .......... 10 NTP Synchronisation ............11 GPS Synchronisation ............
  • Page 4: Introduction

    (RFC1305 & RFC1119) inputs. This flexibility allows the 5200 series master clock to be used as a universal solution for providing time Simple Network Time Protocol (SNTP) v3 and v4 clients synchronisation to many different devices.
  • Page 5: Installation

    Warning - dangerous voltages - the 5200 series Battery backup. master clock must be disconnected from the mains The 5200 series master clock is fitted with a Lithium battery supply prior to removing the top cover. which will maintain the internal time count for a period normally in excess of 1 year if the mains supply is interrupted.
  • Page 6: 5200 Programming

    5200 Series Master Clock Operating and Installation Instructions 3 - 5200 Progamming The 5200 series master clocks have a user friendly interface To select any of the modes whilst they are displayed in the based on the use of four buttons.
  • Page 7: Time Setting Procedure

    5200 Series Master Clock Operating and Installation Instructions 4 - Time Setting Procedure Normal time display: Press Up button to enter ‘Function Menu’. Function Menu ‘Time Setting’ option is selected: Press Up button to access this option. Time is displayed with seconds selected: Press Plus button to zero seconds or Up button to step on to minutes setting.
  • Page 8: Location Setup

    UTC / GMT, the location code should be set to 00. For installations where the output of the 5200 series unit is to be referenced to the ‘local’ time zone, select the appropriate location code from the table opposite.
  • Page 9: City / Location Table

    5200 Series Master Clock Operating and Installation Instructions Issue 1.6...
  • Page 10: Synchronisation Setup

    5200 Series Master Clock Operating and Installation Instructions 6 - Synchronisation Method Setup To provide an increased level of accuracy, the 5200 series Synchronisation Method Setting Procedure master clocks can be configured to synchronise to one of the following sources.
  • Page 11: Ntp Synchronisation

    5200 Series Master Clock Operating and Installation Instructions 6.1 - NTP Synchronisation Setup The 5200 and 5201 master clocks can be configured to The IP address of the NTP time server is specified by synchronise to an NTP time source on a TCP/IP Computer individually entering the four octets of the address.
  • Page 12: Gps Synchronisation

    The four GPS cable cores should be connected to the input connections located on the 10 way terminal block 488HS3 System Installation on the rear of the 5200 series master clock, as shown in the diagram above. To ensure ease of operation and to remove the possibility of...
  • Page 13: Msf And Dcf Synchronisation

    Once the green LED has illuminated the synchronising time that a precise date and time has been calculated from signals are transmitted from the GPS system to the 5200 series the satellite data transmissions. From a ‘cold’ start this master clock. The master clock should lock in and display the process will typically take less than 10 minutes.
  • Page 14: Irig-B Synchronisation

    Operating and Installation Instructions 6.4 - IRIG-B Synchronisation Setup When fitted with the IRIGIN option module, the 5200 series To allow the use of non-UTC based IRIG-B signals (i.e. time master clocks can be configured to synchronise to a 1KHz information provided is offset from UTC), the master clock amplitude modulated IRIG-B signal.
  • Page 15: Network Setup

    5200 Series Master Clock Operating and Installation Instructions 7 - Network Setup of the Internet today it is possible to use NTP to provide accuracy’s of tens of milliseconds, depending on the The 5200 and 5201 master clocks can be configured to operate characteristics of the synchronisation source, stratum of as an NTP time server on a TCP/IP Computer network.
  • Page 16 5200 Series Master Clock Operating and Installation Instructions Network Configuration Procedure Continued First octet of IP address is selected: Press Plus or Minus buttons to increment or decrement value or Up button to step on to second octet of IP address.
  • Page 17 5200 Series Master Clock Operating and Installation Instructions Network Configuration Procedure Continued First octet of gateway address is selected: Press Plus or Minus buttons to increment or decrement value or Up button to step on to second octet of gateway address.
  • Page 18: Zcode Output Setup

    50 bits per second data rate. The signal is virtually immune to panel indicator LEDs. electro-magnetic interference. One 5200 series master clocks can control up to fifty off 4000E zCode Output Configuration or 400A series digital clocks and 47xA series time zone...
  • Page 19 5200 Series Master Clock Operating and Installation Instructions w482 Time Code Output Configuration Normal time display: Press Up button to enter ‘Function Menu’. Function Menu ‘Time Setting’ option is selected: Press Plus button until ‘zCode Output 1’ option is selected.
  • Page 20: Alternate Polarity Impulses

    EMC ground connection on the 10 way The 1 second - seconds only mode is intended for use with 4 terminal block, located on the rear of the 5200 series wire slave clocks requiring both minute and second impulses.
  • Page 21 5200 Series Master Clock Operating and Installation Instructions 24V Alternate Polarity Output Configuration Continued Current Impulse State is selected: Press Minus button to enter Pulse mode or Up button to enter Impulse Time. Pulse mode is selected: Press Plus Current Impulse State is selected: Press...
  • Page 22: Serial Setup

    Data Formats Many of the serial message formats are user programmable. The 5200 series master clocks are fitted as standard with one This allows the user to program information concerning the off RS232 and RS485/RS422 serial data output. The signals are...
  • Page 23 5200 Series Master Clock Operating and Installation Instructions Serial Output Configuration Normal time display: Press Up button to enter ‘Function Menu’. Function Menu ‘Time Setting’ option is selected: Press Plus button until ‘Serial Output 1 Setting’ option is selected. Function Menu ‘Serial Output 1’ option is selected: Press Up button to access this option.
  • Page 24 5200 Series Master Clock Operating and Installation Instructions Serial Output Configuration Continued Current Repetition Rate setting is selected: Press Plus or Minus buttons to increment or decrement value or Up button to step on to Time Offset setting. Current Time Offset setting is selected: Press Plus button select between UTC and Local Time or Up button to exit.
  • Page 25: Serial Messages Table

    User Programmable User Programmable Wharton Format 1 without status User Programmable User Programmable Wharton Format 2 User Programmable User Programmable Wharton Format 2 with day of week User Programmable User Programmable Racal ICR64 User Programmable User Programmable Schauer User Programmable...
  • Page 26 5200 Series Master Clock Operating and Installation Instructions Serial Messages (cont.) Code Message Format Repetition Transmission Notes (Please refer to specified Format application note on CD-ROM) Philips LTC2600 Multiplexer US 5 Min Preset - 9600,8,n,1 US Format Date (LTC2600) Burle TC8286 & TC8288 Multiplexers.
  • Page 27 5200 Series Master Clock Operating and Installation Instructions Serial Messages (cont.) Code Message Format Repetition Transmission Notes (Please refer to specified Format application note on CD-ROM) AIT Comfile 1 Sec Preset - 9600,8,n,1 Team Simoco DX3000 1 Min Preset - 9600,8,n,1...
  • Page 28: Audio Time Code Setup

    Operating and Installation Instructions 10 - Audio Output Setup EBU (LTC) output When fitted with the AFOUT option module, the 5200 series master clocks have two off audio time code outputs which can EBU timecode is used in broadcast applications for ‘stamping’...
  • Page 29: Relay And Lvrelay Setup

    Operating and Installation Instructions 11 - Relay Setup When fitted with the RELAY or LVRELAY option modules, the RELAY Connections 5200 series master clocks have two off voltage free programmable relays. 1A Circuit 1 normally open 1B Circuit 1 normally closed contact...
  • Page 30: System Settings And Status

    5200 Series Master Clock Operating and Installation Instructions 12 - System Settings and Status The System Settings menu and System Statuc displays provide access to general setting information for the 5200 series master clock. System Setting Menu Normal time display: Press Up button to enter ‘Function Menu’.
  • Page 31 5200 Series Master Clock Operating and Installation Instructions System Setting Menu Continued Front Panel LED Status Indicators Current Software Version is displayed: The front panel of the 5000 series network time servers include Press Up button to view Location Code the following front panel status indicators.
  • Page 32 5200 Series Master Clock Operating and Installation Instructions System Status Display Normal time display: Press Plus button to view system date. System date: Press Plus button to view IP assignment configuration. IP assignment configuration (Static, DHCP or Full DHCP): Press Plus button to view IP address.
  • Page 33: Cable Specifications

    7/0.2 (0.22mm ) screened cable. The cable screen up to 1km of cable. For LSOH applications low smoke cable to should be grounded at the 5200 series master clock end by IEC332 and BS4066 may be used. RS 468-1956 (1.5mm Pirelli means of the EMC rear grounding terminal.
  • Page 34 5200 Series Master Clock Operating and Installation Instructions 5200 -> Analogue Impulse Clock interconnection Cabling for analogue clock systems is highly dependent on the number of clocks, power consumption of the clock movements and distance of cable involved. Based on the use of 10mA clock movements, each zCode output of the 5200 master clock could drive 50 clocks.
  • Page 35: Tcp/Ip Concepts

    5200 Series Master Clock Operating and Installation Instructions Appendix B - TCP/IP Concepts IP Address Class C - 192.0.1.x - 223.255.254.x TCP/IP is todays most prevalent networking technology. It can These addresses have a 24 bit network number and an 8 bit be used for small Local Area Networks (LAN) of two or three host addresses.
  • Page 36 5200 Series Master Clock Operating and Installation Instructions ARP & MAC Gateway Address When one device (A) wants to send data to another device (B) The gateway address is used when a device on a network on the same Ethernet LAN it must convert the IP address of the...
  • Page 37 5200 Series Master Clock Operating and Installation Instructions Issue 1.6...
  • Page 38 Wharton Electronics Ltd Unit 15, Thame Park Business Centre, Wenman Road, Thame, Oxfordshire, England. OX9 3XA Email: info@wharton.co.uk WWW: http://www.wharton.co.uk Telephone: +44 (0) 1844 260567 Fax: +44 (0) 1844 218855...