DVP TSC Series Operating And Maintenance Instructions Manual

Side channel blowers

Advertisement

VACUUM
TECHNOLOGY
OPERATING AND MAINT ENANCE
INSTRUCTIONS
(Translation of the original instructions)
SIDE CHANNEL BLOWERS
TSC
TDC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DVP TSC Series

  • Page 1 VACUUM TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS (Translation of the original instructions) SIDE CHANNEL BLOWERS...
  • Page 2: Table Of Contents

    CLEANING THE INTAKE AND OUTLET SILENCERS ............... 21 6.2.7 GREASING THE BEARINGS ......................21 6.2.8 BEARING REPLACEMENT ......................... 21 SPARE PARTS ............................21 RETURNING THE PRODUCT .......................... 21 DISMANTLING ..............................22 TROUBLESHOOTING ............................. 22 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 3: Introduction

    Via Rubizzano, 627 40018 - S. Pietro in Casale (BO) - ITALY +3905118897101 +3905118897170 e-mail: info@dvp.it web site: http://www.dvp.it Please always include the following information in all communications regarding the turbine:  turbine model and serial number;  year of manufacture;...
  • Page 4: Personal Protection Equipment

    IDENTIFICATION PLATE The side channel turbine has an identification plate which shows the manufacturer's name, address, EC label, construction year and its technical data. WARNING Removing or tampering with the identification plate is strictly prohibited. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 5: Safety

    Hazard from the emission of harmful substances Whenever air containing hazardous substances is sucked in (i.e. biological or microbiological agents), use abatement systems located in front of the turbine and divert the exhaust to a protected area. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 6: Pictograms

    D.V.P. Vacuum Technology s.p.a. declines any liability for damage to persons or property resulting from failure to comply with instructions indicated in pictograms or their improper preservation. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 7: Turbine Description

    2/3 of the acceptable maximum pressure with intake and outlet conveyed. The actual sound emission while operating depends, however, on the installation conditions and position of the turbine on the system. Special silencers are available on request to reduce the noise level. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 8: Dimensions And Specifications

    >350 Ø15 405 2-1/2”G 462 15° TSC 550-0 >350 Ø15 405 2-1/2”G 462 15° TSC 550-1 >350 Ø15 405 2-1/2”G 462 15° TSC 1100 >500 Ø16 4”G 0° TSC 1100-1 >500 Ø16 4”G 0° 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 9 Storage/transport room temperature MAX humidity / altitude 80% / 1000 a.s.l. * (*) Please contact the manufacturer if environmental conditions are different from those prescribed. (**) 380-440 / 660-760 (50Hz); 380-480 / 660-830 (60Hz). 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 10 Storage/transport room temperature MAX humidity / altitude 80% / 1000 a.s.l. * (*) Please contact the manufacturer if environmental conditions are different from those prescribed. (**) 380-440 / 660-760 (50Hz); 380-480 / 660-830 (60Hz). 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 11: Tdc Models

    TDC 150-1 Ø12 1-1/2”G 60° TDC 210 Ø14 2”G 51° TDC 210-1 Ø14 2”G 51° TDC 310 Ø15 2”G 51° TDC 310-1 Ø15 2”G 51° TDC 550 Ø15 2-1/2”G 60° Ø15 TDC 550-1 2-1/2”G 60° 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 12 Required workplace temperature °C 0 ÷ 40 °C -20 ÷ 50 Storage/transport room temperature MAX humidity / altitude 80% / 1000 a.s.l. * (*) Please contact the manufacturer if environmental conditions are different from those prescribed. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 13 Required workplace temperature °C 0 ÷ 40 °C -20 ÷ 50 Storage/transport room temperature MAX humidity / altitude 80% / 1000 a.s.l. * (*) Please contact the manufacturer if environmental conditions are different from those prescribed. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 14: Installation

    Lighting All areas must be homogeneously and sufficiently lit to ensure all operations included in this manual can be carried out safely and there should be no shadows, reflections, glare or eye strain. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 15: Turbine Installation

    Make sure that no harmful substances contaminate the user system during installation. Make sure the intake and/or outlet piping is not dirty or blocked. CONNECTION HAZARD The side channel turbine's electric and mechanical connections should only be carried out by qualified and suitably trained personnel. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 16: Intake And Outlet Connection

    The protection with motor protection is essential against overloading risks, in the absence of a network phase, excessive variation of the voltage or turbine block. Adjust the motor protection on the plate's nominal current as the maximum level. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 17 Check that the direction of rotation is correct before starting the turbine for the first time or after resetting the electrical connections. In the event of incorrect rotation direction wait for the turbine to come to a complete halt before changing the connection and supplying power again. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 18: Instructions For Use

    Avoid at all costs that the turbine works with the "inlet closed" especially on machines with high differentials. Insert an intake or compression (outlet) safety valve that can prevent vacuum or overpressure excesses and allow for the levels set in point 3.3 of this manual to be respected. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 19: Stop

     Insulate it from the user system cutting off the intake and outlet connection;  Gradually release the pressure or vacuum that may be inside;  Disconnect the connections to the system;  Shut off the intake and outlet using the specific protections. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 20: Maintenance

    D.V.P. Vacuum Technology S.r.l will be released from any liability relating to the safety of persons and malfunction of the turbine. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 21: Intervention Table

    Checking that the vacuum and/or pressure reducing valves are working must be done by closing the turbine's intake and outlet. In this case the safety devices installed must start working and the electric motor absorption must stay within the levels shown on its plate. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 22: Cleaning The Intake And Outlet Silencers

    RETURNING THE PRODUCT The product may only be returned after prior agreement with the supplier, who will provide the authorisation number that must accompany the material delivered and should be duly completed in its entirety. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 23: Dismantling

    Contact Service Department Dirty silencers. Check and replace (see 6.2.6). Unusual noises coming from the turbine. Dust or process residues on the Contact Service Department turbine's impeller. Vibration transmission from the system. Check and correct. 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 24 User and maintenance manual TSC - TDC 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 25 User and maintenance manual TSC - TDC 8702040 – 14/01/2019 – R.7 www.dvp.it...
  • Page 26 GENERAL CONDITIONS OF SALE D.V.P. Vacuum Technology s.p.a. supplies products exclusively for professional clientele, hence, excluding consumers. PRODUCT WARRANTY TERMS AND CONDITIONS D.V.P. Vacuum Technology s.p.a. guarantees that the product is free from material or manufacturing defects for a period of 24 months of normal use from the shipping date. This period is of 6 months of normal use for products subject to repair not under warranty.
  • Page 27 D.V.P. Vacuum Technology s.p.a. Via Rubizzano, 627 40018 San Pietro in Casale (BO) – Italy Ph +3905118897101 Fx +3905118897170 www.dvp.it...

Table of Contents