The Setup Button - Competition Electronics Turbo35 SE Operating Instructions Manual

Table of Contents

Advertisement

T35 Stealth op inst.
To start the motor run mode, you must have the 'MOTOR VOLTS X.XX' message on the display. Push the (START)
button and the message 'MOTOR ON XX.XX' will appear to indicate that you are actually running. The 'XX.XX' digits
show the supply volts. The current run time in seconds, the motor volts and the motor run current will be displayed on the
top line of the display and are updated constantly. It takes a few seconds for the voltage reading to respond.
The TURBO35 checks to make sure there is no voltage on the leads before it will start the motor. This will prevent you
from starting this function if there is a battery hooked up to the leads. If you start the motor and then turn it off with the
(UP ARROW/OFF) push button, a voltage will remain shown on the screen for a few seconds. This will prevent you from
starting the motor again until the voltage reading goes close to zero.
The motor will take about 3 seconds to wind-up to speed. This is due to the soft start mode used by the TURBO35. This
keeps the power supply from going into current limiting caused by the start-up current of the motor.

THE SETUP BUTTON

Setup mode allows the setting of TURBO35 system values, as described below.
SAVE SETUP SETTABLE VALUES
To get to this mode, push the (SETUP) button until the message 'SAVE SETUP X' appears. Pushing the (START) button
will store all the settable values in one of the three selectable power down memories for use the next time you power up
the TURBO35.
LOAD SETUP SETTABLE VALUES
To get to this mode, push the (SETUP) button until the message 'LOAD SETUP X' appears. Pushing the (START) button
will load all the settable values from one of the three selectable power down memories.
BEEPER
To get to this mode, push the (SETUP) button until the message 'BEEPER: XXXXXX' appears. Pressing the ((UP
ARROW/OFF) button will increment through the possible settings.
The beeper can be set to beep continuously, to beep for five seconds, or not to beep when a charge, discharge, or automatic
cycle is complete.
NAME
The TURBO35 can hold a unique, 9 character name for each of it's 3 setups. This is primarily used to identify machine
data within TURBOLABEL© when more than one machine is connected to the PC running TURBOLABEL©.
It can be set using the standard methods described for editing the other user-changeable settings.
DATA MENU
The data menu can be selected by pushing the (DATA) push button. This menu contains various data collected during the
charge, discharge, and cycle functions. The following is a list of the data displayed in the DATA menu:
*Setup for Data Port configuration
*Peak Charge Voltage
*Relative Internal Resistance
*Actual Internal Resistance
*mA Hr
*mW Hr
*DIscharge Time
*DIscharge Average Voltage
8 of 12
http://www.competitionelectronics.com/media-files/T35_se_op_...
11/30/10 12:41 PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Turbo35 SE and is the answer not in the manual?

Related Products for Competition Electronics Turbo35 SE

Table of Contents