Operating Instruction
HY-MAG
Competition
Serial number: _______________
HYDROTEC
Hydrotec House
4-5 Manor Courtyard
Hughenden Avenue
High Wycombe
HP13 5RE
Tel. 01494 / 796040 Fax 01494 / 796049
- 1 -

Advertisement

loading
Need help?

Need help?

Do you have a question about the HY-MAG Competition and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hydrotec HY-MAG Competition

  • Page 1 Operating Instruction HY-MAG Competition Serial number: _______________ HYDROTEC Hydrotec House 4-5 Manor Courtyard Hughenden Avenue High Wycombe HP13 5RE Tel. 01494 / 796040 Fax 01494 / 796049 - 1 -...
  • Page 2 General Our control box type HY-MAG Competition is a high-quality menu and micro-processor controlled control box providing maximum efficiency for the HY-MAG Water Conditioning Units sizes DN20 to DN65. The control box is set ex works to the individual water conditioning units.
  • Page 3 Normal operation The control box automatically switches to normal operation once the initiating phase has elapsed, whereby the individual actual operation sequences are shown in the display and by the LED lights. The individual operation phases are shown optically. The below display monitoring is shown dur- ing continuous operation.
  • Page 4 Menu sequences Input and programming of HY-MAG Competition control box by pressing the front foil buttons (behind transparent cover) as below: Call up menu. Return from the individual menu levels. Clear parameters. Selection of individual menu sequences in menu levels, modification and setting of parameters.
  • Page 5 The corresponding menu sequence is retrieved with the button and the respective sub- menu shown. Mode of operation The operator can select between 3 different operation modes for the HY-MAG water conditioning units. Continuous operation HY-MAG operates on a continuous 24 hour/day basis Operation mode Continuous operation The control box is in standby mode (LED standby).
  • Page 6 The operator is in a position to reset the relative operating hours by pressing the button once and the relative operating hours counting from the last reset are shown in the display. The operating hours can be cleared by pressing the button once or the buttons also is used to reach and return to the previous display.
  • Page 7 Time zones The switch-on and –off times of the unit can be programmed in the menu ‘Time zones’ after the operation mode ‘Timer control’ was retrieved. One such setting is possible per day. A group of several days or also individual days can be programmed by the operator. Switch-on and switch-off times are controlled and initiated by the internal timer.
  • Page 8 Language The service menu of the HY-MAG Competition control box provides 2 languages. Operation and setting possible in both languages. The menu language is initially be selected by means of the button . The corresponding language is then selected and confirmed by the buttons .
  • Page 9 Failure Indication The Competition control box is provided with an automatic failure recognition. The failure type is shown. In case of failure, the total LED-scale flashes red and the display shows the type of failure. Moreover, it is possible to signal a failure via a potential-free contact. The correct connection is shown in the terminal plan and such relay-contact can be load as below:- Rated current: Rated voltage:...
  • Page 10 Check connection and correct fit of Harting coupling. Failure 2: Overload Failure at magnet coil in water unit. Inform Hydrotec immediately in that case since there are no further local steps possible. The first time the failure had been recognised must be noted.