  • Page 2: Installation Instructions

    DDS Sliding Door Operator in place, these embed plates are to be installed by the General Contractor prior to installation of the DDS Sliding Door Operator and must all be in the same plane. The DDS Sliding Door Operator can be bolted directly to the wall, but DDS recommends the use of embedded steel plates and welding these items securely to the wall.
  • Page 3: Device Housing

    Measure the hole centers on the back of the DDS Sliding Door Operator then transfer them to the appropriate side marking on the horizontal chalk line. Use only high quality 1/2" or 5/8" concrete anchor bolts to fasten the DDS Sliding Door Operator to the wall. Make sure the mounting holes are drilled accurately.
  • Page 4: Finish Welding

    2300-CA ERIES LIDING PERATORS Finish Welding Check all of the installed components for dimension accuracy Weld in strict accordance with the Architectural Plans and Specifications Clean all weld splatter, dress welds and touch up primer. Locking Device Make sure the Door Position Switch and Limit Switch are moved up as far as possible to avoid damage to the switches during installation of the Carriage Assembly.
  • Page 5: Pilaster Lock

    2300-CA ERIES LIDING PERATORS Pilaster Lock Remove the Access Cover located on the front of the Vertical Lock Pilaster Column. Install the Cleavis Mount supplied to your lock with the bolts supplied. Attach the Cleavis Linkage supplied to the Pivot Assembly located in the transom above the Vertical Lock Pilaster Column.
  • Page 6: Special Components

    2300-CA ERIES LIDING PERATORS Special Components See Approved Submittal for drawings and instructions Special Electrical Components See Approved Submittal for drawings and instructions The wiring hook up is referenced in the Approved Submittal Drawings. Page No. 5...
  • Page 7: Specifications

    2300-CA ERIES LIDING PERATORS SPECIFICATIONS Series 2300CA Rack & Pinion Drive Corridor Device Entry and Vestibule Door Operation Device – Door weight not to exceed 400 lbs Housing unit entry and vestibule doors for Level III and Administrative Segregation Housing Units shall have fully automatic sliding doors with functions and components as follows: Unlock, open and lock open by electric switch, a 36 inch wide door in not more than eight seconds.
  • Page 8: Operating Device Transoms, Covers And Accessories

    2300-CA ERIES LIDING PERATORS OPERATING DEVICE TRANSOMS, COVERS AND ACCESSORIES Transoms: Transom backplate is factory punched for six anchor bolts. Horizontal transoms is constructed of 3/16 inch thick steel plate. Transoms shall be rectangular or sloped as indicated. Mezzanine level transoms shall be sloped 26 degrees minimum.
  • Page 9 2300-CA ERIES LIDING PERATORS Weld according to American Welding Society standards. Remove excess welding slag, burrs and rough edges. Prime bare welds using job specified primer. Equipment to be installed under Bid Pack 3 shall be fully fabricated, assembled and finished, ready for final installation and as follows: Work, including wiring, within transoms and emergency release cabinets for sliding doors shall be completed at the factory.
  • Page 10: Product Warranty

    DDS. The warranty period so specified by DDS shall commence on the date of shipment from DDS to the original purchaser. If no period of time is stated, then DDS's Warranty for Standard Products is limited to one (1) year from the date of delivery.
  • Page 11: Parts Lists

    2300-CA ERIES LIDING PERATORS PARTS LISTS Note: When order parts for the following items, always refer first to the Door Number and the appropriate Part No.’s on the Bill of Materials. Some of the parts are sold as assembled items only. Series 2300CA General Assembly (LH as shown, RH opposite) Page No.
  • Page 12: Carriage Assembly (Lh As Shown, Rh Opposite)

    2300-CA ERIES LIDING PERATORS Carriage Assembly (LH as shown, RH opposite) Page No. 11...
  • Page 13: Locking Device Assembly (Lh As Shown, Rh Opposite)

    2300-CA ERIES LIDING PERATORS Locking Device Assembly (LH as shown, RH opposite) Door Open Switch Assembly (LH as shown, RH opposite) Page No. 12...
  • Page 14: Additional Conditions

    2300-CA ERIES LIDING PERATORS ADDITIONAL CONDITIONS Maintenance - Every 12 Months  Check for loose bolts  Check wires for tightness and make sure they are not interfering with any moving parts  Check for abnormal wheel wear  Clean out any debris buildup Adjustments - Non Factory ...
  • Page 15: Table Of Contents

    2300-CA ERIES LIDING PERATORS TABLE OF CONTENTS INSTALLATION INSTRUCTIONS ..........................1 Preparation - New Construction ........................1 Preparation - Existing Construction (retrofit) ....................1 Layout ................................1 Device Housing ............................2 Lock Pilaster Column ........................... 2 Rear Lock Tube ............................2 Wall Guide ..............................
  • Page 16 2300-CA ERIES LIDING PERATORS Maintenance - Every 12 Months ........................13 Adjustments - Non Factory ........................... 13 FACTORY INFORMATION ............................13 Location ................................ 13 Hours ................................13 Phones ................................. 13 TABLE OF CONTENTS ............................... 14 BILL OF MATERIALS ..............................16 Page No.