BMR PLA34 User And Service Manual

BMR PLA34 User And Service Manual

Power quality analyzer class s

Advertisement

Quick Links

PLA 34
Power quality analyzer class S
User and service manual
version 1.0
BMR trading
Horní lán 17
Tel: +420 778 066 566
779 00 Olomouc
export@bmr-trading.com
Czech Republic
1
www.bmr-trading.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PLA34 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BMR PLA34

  • Page 1 PLA 34 Power quality analyzer class S User and service manual version 1.0 BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 2: Table Of Contents

    7.3.6.2 Display settings............18 4.6. Digital inputs / outputs........6 7.3.6.3 Data storage............18 7.3.7. Memory settings..........19 5. Operation..............6 7.3.8. About..............20 7.4. Connection of PLA34 to LAN with NAT server. 21 5.1. Screens structure..........7 8. Technical features............22 5.1.1. Flicker..............8 6. Web server..............8 BMR trading Horní...
  • Page 3: Front Panel

    – cursor key for moving up in menu and parameter change to higher value – cursor key for moving down in menu and parameter change to lower value – ESC key for canceling or return Picture 2: Rear panel description BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com...
  • Page 4: Device Description

    3. Installation PLA34 is prepared for wall mounting in the fixed switch boards. In order to assure well ventilation, the PLA34 has to be installed vertically. There has to be empty space at least 50 mm at the top and bottom and 20 mm at the sides.
  • Page 5: Connection

    4.1. Supply voltage Supply voltage is required to operate the PLA34. The type and level of the necessary supply voltage is written on the back label. Before applying the supply voltage, make sure that the voltage level and system frequency match the details on the label.
  • Page 6: Rs485

    Development and production of systems for measurement and control 4.3. RS485 The PLA34 has built-in one RS485 interface supporting Modbus RTU protocol. Connection of the RS485 bus to the device is on the separate terminal by two wires A and B. Shielding is not required.
  • Page 7: Screens Structure

    Current in neutral Current THD current harmonics current harmonics ▼ ▼ ▼ ▼ ▲ System frequency ▲ Cos φ Power factor ▼ ▲ BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 8: Flicker

    ▼ 5.1.1. Flicker Device calculates flicker according to the norm EN61000-4-15. It provides values for short-term flicker (10 minutes), long-term flicker (2 hours). 6. Web server BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 9: Device Settings

    Development and production of systems for measurement and control 7. Device settings PLA34 device can be configured from panel screen for most of the essential parameters. Configuration menu is divided to the two sub-menus for device fundamental settings and menu for communication interfaces settings. Enter the configuration menu by pressing the button SET for at least 5 seconds.
  • Page 10: Main Parameters

    Averaging period Time for averaging period setting 1 ... 3600s Storage interval Interval of energy meters profile 15 min 15, 30, 45, 60 min BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 11 Development and production of systems for measurement and control BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 12: Lan Settings

    Password FTP server password 1234 FTP port Port of FTP server Modbus TCP Activates the Modbus TCP communication protocol of PLA34 Modbus port Port of Mobus TCP communication BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com...
  • Page 13: Ntp Server, Time Zone

    7.3.3. NTP server, Time zone PLA34 corrects internal clock according to NTP servers while it is connected to Internet. NTP time synchronization has always priority above the manual clock settings. Clock synchronization by NTP is fully automatic and there is no need to set anything.
  • Page 14: Transient

    0 ... 8000 Memory for capturing the transients amplitude is fixed on the maximum of 8000 samples. Definition of number Pre and Post samples is limited by this maximum samples memory space. BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com...
  • Page 15: Event

    Development and production of systems for measurement and control 7.3.5. Event Events captured by PLA34 are fully adjustable by the parameters described in the list beneath. Parameter Description Factory setting Setting range Reference Reference voltage level type Udin Udin / Sliding...
  • Page 16: Rvc, Ripple Control

    50 Hz ... 3 kHz According to the norm the ideal settings is RVC threshold on 3.5% of Udin and hysteresis on 1% of Udin. 7.3.6. Inputs/Outputs BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com...
  • Page 17: Alarms

    Development and production of systems for measurement and control 7.3.6.1 Alarms BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 18: Display Settings

    Measured parameters can be recorded in the internal flash memory. For this purposes setup cart Data storage offers the list of all parameters that can be stored. PLA34 allows to define 5 different time intervals with adjustable time and recorded parameters.
  • Page 19: Memory Settings

    Development and production of systems for measurement and control 7.3.7. Memory settings Settings related to RS485 interface with Modbus RTU protocol support. BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 20: About

    Development and production of systems for measurement and control 7.3.8. About Information about the vendor and device firmware version. BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...
  • Page 21: Connection Of Pla34 To Lan With Nat Server

    7.4. Connection of PLA34 to LAN with NAT server If there is request for remote access (from Internet) to PLA34, which is place in the local network behind the router with active NAT server, the following parameters configuration to be defined on the router.
  • Page 22: Technical Features

    Weight 1000 g Protection degree IP20 rear cover / IP54 front panel Related standards IEC 61000-4-30 class A, IEC 61000-4-7, IEC 61000-4-15, IEC61557-12 BMR trading Horní lán 17 Tel: +420 778 066 566 779 00 Olomouc export@bmr-trading.com Czech Republic www.bmr-trading.com...

Table of Contents