  • Page 1      National Comfort Products National Comfort Products 539 Dunksferry Road • Bensalem, PA 19020 • (215) 244-1400 • 1-800-523-7138 • Fax: (215) 639-1674 539 Dunksferry Road • Bensalem, PA 19020 • (215) 244-1400 • 1-800-523-7138 • Fax: (215) 244-9579 14299573 03/10 14299575-10/29/2014...
  • Page 2 NOTE: These installation and maintenance instructions should be left with the unit for future reference. INSTALLATION: This unit must be installed in accordance with all appli- cable codes. This unit is not to be used for temporary heating of buildings or structures under construction. FOR MAXIMUM PERFORMANCE , IT IS IMPERATIVE THAT THE COOLING CHASSIS AIR DIVIDER BE SEALED...
  • Page 3 Part Numbers Input (Mbh) safety and performance related problems. Avoid installing the unit near sources or vents that may contain the 14208309/HS038 following contaminants: 14208308/HS051 14208303/HS064 a. Permanent Wave Solutions b. Chlorinated Waxes and Cleaners INQUIRIES AND PARTS ORDERS c.
  • Page 4 If the Comfort Pack is installed so that supply ducts carry The ignitor assembly may be removed and cleaned using air circulated by the furnace to areas outside the space emery cloth. The spark gap should be set at 1/8”. containing the furnace, the return air shall also be handled by a duct(s) sealed to the furnace casing and terminating The venter motor bearings are permanently lubricated.
  • Page 5 With the burner assembly removed, shine a flash light on the burner ribbons. Look for carbon buildup, scale, dust, lint, and/or anything that might restrict flow through the spaces between the burner ribbons. Holding the burner assembly so that any foreign material will fall away from the burner, use a stiff bristle brush to loosen and remove any foreign materials.
  • Page 6 Wiring Schematic/Gas Heat Black To Thermostat Door Sw Spark Ign Orange White Black White White Black Black Yellow Dual Capacitor Herm Yellow Orange Press Sw Compressor Black Blue Black Blue Brown Purple Black Cond Mtr 230V COIL Note 1: Fan ON delay in cooling 35-40sec Evp Mtr 1 High - Red...
  • Page 7 Wiring Schematic/Gas Heat Black To Thermostat Door Sw Spark Ign Orange White Black White White Black Black Yellow Dual Capacitor Herm Blue Orange Press Sw Compressor Black Blue Black Blue Brown Purple Black Cond Mtr 230V COIL Note 1: Fan ON delay in cooling 35-40sec Evp Mtr 1 High - Red...
  • Page 8 Legend DSI INTEGRATED CONTROL MODULE CONTROL GREEN LED STATUS STEADY ON Normal operation, no call for heat FAST FLASH Normal operation, call for heat 1 FLASH In lockout from failed ignition or flame loss 2 FLASH Pressure switch does not close within 30 seconds 3 FLASH Limit switch or rollout switch open 4 FLASH...
  • Page 12 COMFORT PACK R-410A - Gas Furnace Instructions - Rev 14299575-10/29/2014...