Important: The Gluco Spark meter should only be used with Gluco Spark test strips. Using other test strips with this meter can produce inaccurate results. Do use the Gluco Spark system for: Testing blood glucose.
Areas for the Hand Forearm Hand Fingertips Thigh Calf The human figure above shows the areas where you can test with the Gluco Spark System. Avoid moles, veins, bones, and tendons. Warning: We recommend that you test on your fingers for better results.
Gluco Spark meter and how it works This screen always appears when the meter is turned on so that you can make sure the display is working properly. Do not use the meter if the system check screen does not...
® Sensa Core Gluco Spark Meter Display Battery Symbol Blood Drop Symbol This symbol works with s t r i p s y m b o l i n a n animation to tell you when the meter is ready to apply blood.
The cap or vial contains drying agents that may be harmful if inhaled or swallowed and may cause skin or eye irritation. Important: The Gluco Spark Meter should only be used with Gluco Spark Test Strips. Using other test strips with this meter can produce inaccurate results. Important Test Strip Information The Gluco Spark system has an operating range of 2°...
The meter will power on. Note: If you do not start the test within one minute, the meter will turn off. To restart the meter, take out the unused Gluco Spark test strip and reinsert it into the meter. System check screen...
Do not press the Gluco Spark test strip against the test site. Do not scrape the blood onto the Gluco Spark test strip. Do not apply blood to the top side of the Gluco Spark test strip. Do not apply blood to the Gluco Spark test strip when the Gluco Spark test strip is out of the meter.
Waiting for result Do not pull the Gluco Spark test strip away until you hear one beep or see the timer starting on your meter screen. this means you have enough blood and the meter is reading your glucose. If after five seconds your meter does not...
LO and HI Readings Important: Low or high blood glucose readings can indicate a potentially serious medical condition. The Gluco Spark Meter displays results from 20 to 800 mg/dL LO Reading with Symptoms If you have a reading below 70 mg/dL and have symptoms...
Meter Maintenance Battery Your Gluco Spark meter comes with one preinstalled, 3 volt, lithium battery. The battery provides enough power for the meter to perform about 1000 Tests. If your battery runs low, the battery needs to be replaced. Replacing the Battery...
Date and Time Set-Up (On Replacement of Battery) Your Gluco Spark meter allows you to set the Date and Time as you like. You can view 24 hour time. To get into set-up mode, remove the battery and replace it. A complete display will briefly appear, then numbers will flash in the bottom left corner of the display.
Taking care of your meter is very simple. Just follow the guidelines shown below Do not disassemble your meter. If you have any questions, please contact your local authorized distributor of Gluco Spark Blood Glucose Monitoring System. Please use your meter carefully. Avoid throwing, shaking, or dropping it, which may damage its internal parts.
System troubleshooting Error messages When an error occurs, an error message appears on the display with continuous beep sound. Turn the meter off by ejecting the strip. If your meter has been dropped, this can also lead to error messages. If error messages occur frequently, contact your customer support and service centre.
(+) sign battery in the meter. facing upward, towards you. Test strip inserted upside Insert the Gluco Spark Test Strip down, wrong end in, or with the white sheet with sample incompletely inserted into inlet side up and the top of the the meter.
Technical Specifications Gluco Spark system specifications Determination of glucose in fresh Test Principle capillary whole blood Assay Method Amperometric Bio sensor After 5 seconds, depending on Automatic Shutoff operating status Hematocrit 15 % to 65 % Measurement Units mg/dL Strips Storage Temp.
Page 24
SENSA CORE Medical Instrumentation Pvt. Ltd. Plot No: 3, Export Promation Industrial Pack, Pashamylaram, Sangareddy (Dist.), Hyderabad - 502307, Telangana, INDIA. Tel: +08455 - 223400, www.sensacore.com Customer Care Number 1800 200 2880...
Need help?
Do you have a question about the Gluco Spark and is the answer not in the manual?
Questions and answers