Site Requirements; Electrical Requirements - Bunn NITRON2 NGM Installation & Operating Manual

Nitron gas module
Table of Contents

Advertisement

The Nitron Gas Module dimensions are 8.3"W x 13.8"D x 4.7"H. The NGM should be placed in a upright position on
a solid surface nearest or directly underneath the Nitron Cold Draft Dispenser. Environment must be below 90 Degrees F,
50% or lower humidity, such as in a cafe, convenience store, or restaurant and not near other appliances that may emit
gasses, oils, or other fluids. Do Not allow vents on the sides of the NGM to get blocked.
CAUTION: To reduce the risk of Electric Shock or Injury, use and store indoors only. Adapter plugs or extension cords may
not be used to facilitate electrical hook-up to the equipment power cord.
APPLICATION: The NGM is not to be used with a Keg style dispense systems. The output pressure of the NGM will be
around 100-112psig.
The 120V rated Nitron Gas Module has an attached cord set and requires a 2-wire, grounded, individual branch circuit
rated 120 volts ac, 15 amp, single phase, 60Hz. The mating connector is NEMA 5-15R.
Refer to the data plate for exact electrical requirements.
CAUTION: To reduce the risk of Electric Shock or Injury, use and store indoors only. Adapter plugs or extension cords may
not be used to facilitate electrical hook-up to the equipment power cord.
GROUNDING INSTRUCTIONS
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING: Improper installation of the grounding plug is able to result in a risk of electric shock. When repair or
replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal. The
wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
Contact a qualified electrician or serviceman when the grounding instructions are not completely understood, or
when in doubt as to whether the product is properly grounded. Do not modify the plug provided; if it does not fit
the outlet, have the proper outlet installed by a qualified electrician.

SITE REQUIREMENTS

ELECTRICAL REQUIREMENTS

6
120 Volt
Plug