PVI MTRX Manual

Digital tuner streamer

Advertisement

Quick Links

This Manual Apply to the MTRX 4/8 Tuner To IPTV Systems
On 8 Tuners Systems, The inputs are all assigned to the 8 Tuners Only and no asi
Digital Tuner Streamer
Web-NMS Version: 1.03
Software: 1.00
Hardware: 0.40

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTRX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PVI MTRX

  • Page 1 Digital Tuner Streamer This Manual Apply to the MTRX 4/8 Tuner To IPTV Systems On 8 Tuners Systems, The inputs are all assigned to the 8 Tuners Only and no asi Web-NMS Version: 1.03 Software: 1.00 Hardware: 0.40...
  • Page 2: Table Of Contents

    4 in 1 IRD User’s Manual DIRECTORY Chapter 1 Product Outline ................1 1.1 Outline ........................1 1.2 Features........................1 1.3 Specifications ......................2 1.4 Principle Chart ......................4 1.5 Appearance and description................... 4 Chapter 2 Installation Guide ................. 6 2.1 Acquisition Check ....................
  • Page 3: Chapter 1 Product Outline

    Chapter 1 Product Outline 1.1 Outline MTRX IRD is PVI’s new design which integrates demodulation (DVB-C, T/T2, S/S2 optional), de-scrambler and multiplexing in one case to convert RF signals into TS output. It is a 1-U case which supports 4 tuner inputs, 1 ASI and 4 IP inputs. The 4 CAMs/CIs accompanied can descramble the programs input from encrypted RF, ASI and IP.
  • Page 4: Specifications

    1.3 Specifications 2 / 38...
  • Page 5 4-in-1 IRD User’s Manual Code rate 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, Input 4x RF (DVB-C, T/T2, S/S2 optional), F type 8/9, 9/10 1×ASI input for de-mux, BNC interface Constellation QPSK, 8PSK 4xIP input for de-mux (UDP) Output 48*SPTS over UDP, RTP/RTSP. Tuner Section DVB-C 1000M Base-T Ethernet interface...
  • Page 6: Principle Chart

    4-in-1 IRD User’s Manual 1.4 Principle Chart ASI Out 1 SAT RF 1 IP 1 ASI Out 2 SAT RF 2 IP 2 ASI Out 3 SAT RF 3 IP 3 ASI Out 4 SAT RF 4 IP 4 IP (48 SPTS) Out 4 x CAM/CI choose 4 channels from all inputs to descramble CI 1 &...
  • Page 7 4-in-1 IRD User’s Manual CAM/CI Slots 1 & 2 (Applied to descramble tuner 1 & 2, ASI input and IP input 1 to 4) Tuner Input 1 & 2 CAM/CI Slots 3 & 4 (Applied to descramble tuner 3 & 4, ASI input and IP input 1 to 4) Tuner Input 3 &...
  • Page 8: Chapter 2 Installation Guide

    Chapter 2 Installation Guide 2.1 Acquisition Check When user opens the package of the device, it is necessary to check items according to packing list. Normally it should include the following items:  MTRX 4-in-1 IRD 1pcs  Power Cord 1pcs If any item is missing or mismatching with the list above, please contact our company.
  • Page 9 4-in-1 IRD User’s Manual Item Requirement When user installs machine frame array in one machine hall, the distance between 2 rows of machine Machine Hall Space frames should be 1.2~1.5m and the distance against wall should be no less than 0.8m. Electric Isolation, Dust Free Volume resistivity of ground anti-static material: ,...
  • Page 10: Wire's Connection

    When the device adopts united way, the grounding resistance should be smaller than 1Ω. Caution: Before connecting power cord to MTRX IRD, user should set the power switch 8 / 38...
  • Page 11: Signal Cable Connection

    2.4 Signal Cable Connection The signal connections include the connection of input signal cable and the connection of output signal cable. The details are as follows: 2.4.1 MTRX 4-in-1 IRD Cables Illustration:  IP Input/output Cable Illustration:  Tuner Cable Illustration: ...
  • Page 12 4-in-1 IRD User’s Manual 10 / 38...
  • Page 13: Chapter 3 Operation

    4-in-1 IRD User’s Manual Chapter 3 Operation The front panel of MTRX 4-in-1 IRD is the user-operating interface and the equipment can be conveniently operated and managed according to the procedures displayed on the LCD: Keyboard Function Description: LEFT/RIGHT: Choose and set the parameters.
  • Page 14 4-in-1 IRD User’s Manual Initializing 4 in 1 IRD Bitrate: 70.865Mbps Alarm 1 Status Uptime Satellite frequency 2.1 Tuner DVBS/S2 2 Input Sets Tuner Parameters LNB frequency Symbol rate LNB voltage Signal Lock TS Lock Mux Program Parse Program Select Program ‘...
  • Page 15 4-in-1 IRD User’s Manual 4 TS Config 4.1 TS output bitrate 4.2 ASI 1 out select 4.3 ASI 1 out bitrate 4.4 ASI 2 out select 4.5 ASI 2 out bitrate 4.6 ASI 3 out select 4.7 ASI 3 out bitrate 4.8 ASI 4 out select 4.9 ASI 4 out bitrate 4.10 TSID...
  • Page 16: General Setting

    4-in-1 IRD User’s Manual 3.2 General Setting Switch on the device and after a few seconds’ initialization, it presents start-up pictures as below: 4 in 1 IRD Start up… Start OK… Bitrate: xx.xxx Mbps  4 in 1 IRD: Device’s name ...
  • Page 17 4-in-1 IRD User’s Manual 3.2.2 Input Sets MTRX supports 4 tuners input, 1 ASI input and 4 IP stream input. Users can enter ‘Input Sets’ to configure the tuner/ASI/IP parameters to receive the transport streams and select programs to output via IP (SPTS) packages. It displays as below: 2.1 Tuner DVBS/S2 2.2 Tuner DVBS/S2...
  • Page 18 4-in-1 IRD User’s Manual For reading the input TS Locked Mux Program bitrate Bitrate: 4.040 Mbps TS Lock Parse Program For reading the number Searching Program Select Program programs from Get 7 Programs Tuner 1 (or 2) Mux Program (0/7) 1: TV 1 Process of selecting programs to Press ENTER key...
  • Page 19 2.5.3 Select Program 3.2.3 CI Card MTRX IRD supports 4 CI cards (Card A, B, C and D) to descramble encrypted programs from RF, ASI or IP. Users can press ENTER key to enter ‘3 CI Card’ to configure the 4 cards respectively.
  • Page 20 4-in-1 IRD User’s Manual  Input TS Mode MTRX has 9 signal sources: Tuner 1-4, ASI, and IP1-4. One CI card can applied to descramble one channel input signal from the 9 signal sources. ‘Skip CI card’ means to skip the card which is used for FTA stream.
  • Page 21 TS output bit rate 054 Mbps ASI X out select: MTRX is equipped with 4 pairs of ASI out ports. Each pair can transfer one channel of tuner or one channel of IP content of corresponding channel. For instance, user can select content from “tuner 1” or “IP 1” to output through “ASI 1”.
  • Page 22 ON ID: Users can set ON ID (original network ID) in this menu. ON ID 00001 3.2.5 IP Stream MTRX IRD supports 48 SPTS over IP (UDP, RTP/RTSP) output. Users can set the IP out parameters in this menu.. 5.1 Service IP 5.2 Subnet Mask 5.1 -5.4: To configure...
  • Page 23 4-in-1 IRD User’s Manual 3.2.6 Network Users can set network parameters in this menu. Enter ‘Network’ submenus to separately set corresponding parameters. 6.1 NMS IP 6.2 Subnet Mask 6.3 Gateway 6.4 MAC Address 6.5 Web NMS Port 6.6 Reset Password address NMS IP connecting the device to PC...
  • Page 24 4-in-1 IRD User’s Manual 7.9 Version Save Configuration? Choose yes to save settings. and press ENTER to confirm Choose yes to restore the Load Saved CFG? device into the last saved configuration. Reset All Sets? Choose yes to restore the device into factory’s default configuration.
  • Page 25: Chapter 4 Web-Based Nms Management

    4-in-1 IRD User’s Manual Chapter 4 Web-based NMS Management In addition to using front buttons to control the device, users can also control and set the configuration with the web Brower in the PC. 4.1 login The default IP address of this device is 192.168.0.136. (We can modify the IP through the front panel.) Connect the PC (Personal Computer) and the device with net cable, and use ping command to confirm they are on the same network segment.
  • Page 26: Operation

    4-in-1 IRD User’s Manual 4.2 Operation Summary: When we confirm the login, it displays the WELCOME interface as Figure-2 where users can have an overview of the device’s system information and working status. Language shift area System information Input information of the 4 satellite signals, ASI and 4 IP streams.
  • Page 27 4-in-1 IRD User’s Manual Parameters → Input 1/2/3/4 (Tuner Input 1-4): From the menu on left side of the webpage, clicking “Input 1” (or “Input 2/3/4”), it displays the interface where users can configure the 4 Tuner input parameters separately. (Figure-3) Configure tuner Tuner...
  • Page 28 4-in-1 IRD User’s Manual Figure-4 Parameters → Input 6/7/8/9 (IP Input 1-4): From the menu on left side of the webpage, clicking “Input 6” (or “Input 7/8/9”), it displays the interface where users can configure the IP input parameters separately. (Figure-5) Configure IP parameters in this area according to...
  • Page 29 4-in-1 IRD User’s Manual Parameters → CI Card: MTRX supports 4 CI cards (Card A, B, C and D) to descramble programs from encrypted RF, ASI or IP. Users can click and enter ‘CI Card’ to configure the 2 cards respectively.
  • Page 30 NOTE!  Input TS Mode MTRX has 9 signal sources: Tuner 1-4, ASI, and IP 1-4. One CI card can applied to descramble one channel input signal from the 9 signal sources. ‘Skip CI card’ means to skip the card which is used for FTA stream.
  • Page 31 4-in-1 IRD User’s Manual input 1 to 4, while card C & D A are designed to descramble tuner 3 & 4, ASI input and IP input 1 to 4.  Card Error Check Users can decide whether to enable or disable the card error check function by checking the box.
  • Page 32 Configure TS ID and ON ID here for the output stream. Figure-8 ASI X out select: MTRX is equipped with 4 pairs of ASI out ports. Each pair can transfer one channel of tuner or one channel of IP content of corresponding channel.
  • Page 33 4-in-1 IRD User’s Manual ASI X out bit-rate: Users can set TS output bit rate for the corresponding channel. After finishing the configuration, click to confirm. Parameters → Mux: From the menu on left side of the webpage, clicking “Mux”, it displays the interface where users can configure the programs to be multiplexed.
  • Page 34 4-in-1 IRD User’s Manual  Program Modification: The multiplexed program information can be modified by clicking the program in the ‘output’ area. For example, when clicking , it triggers a dialog box (Figure 10) where users can input new information. This device supports 48 SPTS IP out.
  • Page 35 4-in-1 IRD User’s Manual This unit supports TS output in IP (48 SPTS). Click “IP Stream” and it displays the interface where users can configure the SPTS out parameters. (Figure-13) Figure-13 Parameters → Network: From the menu on left side of the webpage, clicking “Network”, it will display the screen as Figure-14 where to configure the network parameters for the device.
  • Page 36 4-in-1 IRD User’s Manual From the menu on left side of the webpage, clicking “LCD/Keyboard”, it will display the screen as Figure-15 where to control the device’s front panel. Figure-15 System → Password: From the menu on left side of the webpage, clicking “Password”, it will display the screen as Figure-16 where to set the login account and password for the web NMS.
  • Page 37 4-in-1 IRD User’s Manual Figure-17 System → Backup/Load: From the menu on left side of the webpage, clicking “Backup/Load”, it will display the screen as Figure-18 where to backup or load your configurations. Figure-18 35 / 38...
  • Page 38 4-in-1 IRD User’s Manual System → Firmware: From the menu on left side of the webpage, clicking “Firmware”, it will display the screen as Figure-19 where to update firmware for the device. Figure-19 System → Reboot: From the menu on left side of the webpage, clicking “Reboot”, it will display the screen as Figure-20 where to restart the device manually.

Table of Contents