PCB Piezotronics TCS-2A Installation And Operating Manual

Reaction torque sensor

Advertisement

Quick Links

Model 2508-01A/TCS-2A
Reaction Torque Sensor
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-828-8840
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: info@pcb.com
Web: www.pcb.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCS-2A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PCB Piezotronics TCS-2A

  • Page 1 Model 2508-01A/TCS-2A Reaction Torque Sensor Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
  • Page 2 Piezotronics, user servicing or repair is critical test. not recommended and, if attempted, may void the factory warranty. Routine PCB Piezotronics maintains an ISO- maintenance, such as the cleaning of 9001 certified metrology laboratory and electrical connectors, housings, and offers calibration services, which are...
  • Page 3 50% of the general contact numbers are: replacement cost returned item(s). PCB will provide a price PCB Piezotronics, Inc. quotation replacement 3425 Walden Ave. recommendation for any item whose Depew, NY14043 USA repair costs would exceed 50% of...
  • Page 4 PCB工业监视和测量设备 - 中国RoHS2公布表 PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 有害物质 汞 镉 六价铬 (Cr(VI)) 多溴联苯 (PBB) 多溴二苯醚 (PBDE) 部件名称 铅 (Pb) (Hg) (Cd) 住房 PCB板 电气连接器 压电晶体 环氧 铁氟龙 电子 厚膜基板 电线 电缆 塑料 焊接...
  • Page 5 Component Name Hazardous Substances Lead Mercury Cadmium Chromium VI Polybrominated Polybrominated (Pb) (Hg) (Cd) Compounds Biphenyls Diphenyl (Cr(VI)) (PBB) Ethers (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
  • Page 6: Table Of Contents

    REACTION TORQUE SENSOR OPERATION MANUAL TABLE OF CONTENTS Section Page 1.0 Introduction 2.0 Safety Information 3.0 Mechanical Installation 4.0 Electrical Installation 5.0 Polarity 6.0 Shunt Calibration 7.0 Operation 8.0 Troubleshooting 9.0 Maintenance LIST OF ILLUSTRATIONS Figure Page 1. Flange Mount Reaction Torque Sensor 2.
  • Page 7: Introduction

    REACTION TORQUE SENSOR OPERATION MANUAL 1.0 INTRODUCTION Gage Committee as revised in May 1960. wiring code is as follows: Reaction torque sensors manufactured by the Force- Torque Division of PCB are strain gage based measuring instruments suitable for a wide range of torque measurement applications.
  • Page 8: Safety Information

    REACTION TORQUE SENSOR OPERATION MANUAL thrust and bending moment that may be applied without electrical or mechanical damage to the torque sensor. Do not exceed moment (W x S) or shear (W) whichever attained first. Measurement inaccuracy and structure damage may result. Install the sensor in a manner that minimizes these loads.
  • Page 9: Electrical Installation

    REACTION TORQUE SENSOR OPERATION MANUAL 4.0 ELECTRICAL INSTALLATION As the host structure (diaphragm, bending beam, shear beam, column, etc.) is loaded or stressed, the For proper electrical connections, refer to the Wheatstone Bridge becomes unbalanced, resulting installation drawing for the torque sensor, and the in an output signal that is proportional to the applied wiring drawing for the signal conditioner used.
  • Page 10: Operation

    REACTION TORQUE SENSOR OPERATION MANUAL 6. Record the value of the signal conditioner’s used. This value, and the particular resistor, are output signal and/or numeric display. This now matched to the transducer and form a basis value is the shunt calibration value, or of the transferable shunt calibration.
  • Page 11: Troubleshooting

    REACTION TORQUE SENSOR OPERATION MANUAL 8.0 TROUBLESHOOTING Measurement sensors are designed and built to withstand these non-measured forces and bending No output moments (extraneous loads), the errors due to them No power are present. PCB engineers can design the set-up to Loose or dirty connections eliminate or minimize these extraneous loads.
  • Page 12 REACTION TORQUE SENSOR OPERATION MANUAL Caution should be observed to insure that liquids are not permitted to migrate into devices that are not hermetically sealed. Such devices should only be wiped with a damp cloth and never submerged or have liquids poured on them.
  • Page 13 908 g Mounting Flange (#10-24 Bolts) Flange (No Metric Equivalent) PCB Load & Torque Torsional Stiffness 2350 lbf-in/radian 265.5 N-m/radian A Division of PCB Piezotronics Sensing Element Strain Gage Strain Gage 24350 Indoplex Circle Housing Material(Sensor) Anodized Aluminum Anodized Aluminum...
  • Page 14 PCB Load & Torque Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others without DESCRIPTION the written consent of PCB Load and Torque Inc. UPDATED GD&T SPECS - 05.02.16, PTE 45413 PT02E-10-6P RECEPTACLE PIN A +EXC.