Operation Guide
Thank you for purchasing the Larson Electronics CL1B-MS-1224 LED
beacon. Follow the steps below for installing and maintaining your unit.
Installation
• Carefully unpack the unit and place it near your mounting location.
• Mount the beacon in your desired location using the three predrilled
holes located on the base. Wire routing should be taken into
consideration when choosing a mounting location. This unit allows
indoor or outdoor mounting as long as the appropriate wire routing is
used.
• We strongly recommend that only a licensed electrician install this
product.
12-24V DC MODEL (-1224)
RED + (POSITIVE)
BLACK - (NEGATIVE)
Flash Patterns
The CL1B LED Beacon is programmed with 30 different flash patterns listed
below.
Synchronous Flash Patterns
FP1: Single Alert 75 PHASE 1 (sim)
FP2: Single Alert 75 PHASE 2 (sim)
FP3: Quad Flash 75 PHASE 1 (sim)
FP4: Quad Flash 75 PHASE 2 (sim)
FP5: Double Flash 150 PHASE 1 (sim)
FP6: Double Flash 150 PHASE 2 (sim)
FP7: Double Flash 75 PHASE 1 (sim)
FP8: Double Flash 75 PHASE 2 (sim)
FP9: Single Flash 375 PHASE 1 (sim)
FP10: Single Flash 375 PHASE 2 (sim)
FP11: Single Flash 150 PHASE 1 (sim)
(sim): Front and rear LEDS fire simultaneously
LEDS alternate
CL1B-MS-1224
FP12: Single Flash 150 PHASE 2 (sim)
FP13: Single Flash 75 PHASE 1 (sim)
FP14: Single Flash 75 PHASE 2 (sim)
FP15: Single Alert 75 (alt)
FP16: Quad Alert 75 (alt)
FP17: Double Flash 150 (alt)
FP18: Double Flash 75 (alt)
FP19: Single Flash 375 (alt)
FP20: Single Flash 150 (alt)
FP21: Single Flash 75 (alt)
(alt) Front and rear
Larson Electronics LLC
Non-synchronous Flash Patterns
FP22: Single Alert 75 PHASE 1 (sim)
FP23: Single Alert 75 PHASE 2 (sim)
FP24: Quad Flash 75 PHASE 1 (sim)
FP25: Quad Flash 75 PHASE 2 (sim)
FP26: Double Flash 150 PHASE 1 (sim)
(sim): Front and rear LEDS fire simultaneously
LEDS alternate
Synchronization
•
To Sync two beacons, configure both beacons to display the same
Phase 1 pattern.
•
With the power off, connect the YELLOW wires from each beacon
together.
•
When the beacons are activated, their patterns will be synchronized.
•
To configure the two light heads to alternate their patterns, advance the
pattern of either beacon to the Phase 2 mode of the current pattern.
NOTICE: Do not SYNC more than 8 beacons!
Setting the Flash Pattern
Each pattern can be selected by pressing the momentary toggle switch. The
selected pattern will remain during power cycles.
•
Less than 1 second for the NEXT pattern
•
1 to 3 seconds for the PREVIOUS pattern
•
3 to 5 seconds for the DEFAULT pattern
•
Greater than 5 seconds to TURN OFF the beacon
Ver.0518-1
FP27: Single Flash 150 PHASE 2 (sim)
FP28: Single Flash 75 PHASE 1 (sim)
FP29: Single Flash 75 PHASE 2 (sim)
FP30: Single Alert 75 (alt)
(alt) Front and rear