OPERATING INSTRUCTIONS!
!
The Bartol
"Mag-Probe" is an
sensing magnetic fields.!
!
CAUTION:
Damage may result
Probe" Is
dropped.!
General applications!
All voltages
(AC
& DC)!
Solenoids,
Solenoid
valves,
relays,
Coils, Rotary
switches,
Detecting
Coils,
Transient
current
North & South
poles,
etc.!
The white magnetic shield on the "Mag-
Probe's"
tip reduces the chance of
magnetic fields turning it on during
storage and must be removed before
using. Replace the magnetic shield after
using.!
!
DO NOT STORE THE "MAG-PROBE" NEAR A
PERMANENT MAGNET OR MAGNETIC FIELD.!
!
A
"Mag-Probe"
will not detect devices
enclosed in a magnetic shield.
devices aren't
shielded.)!
!
You may self test the "Mag-Probe"
High/Low sensitivity ring supplied with each
unit.!
!
TESTING AC & DC DEVICES WITHOUT!
USING THE
HIGH/LOW
Page. 5 !
Instrument
for
if
the
"Mag-
Relays,
Reed
solenoids,
Stepper
residual
magnetism,
pulses,
Identifying
(most
with the
SENSITIVITY RING!
1. Hold the
"Mag-Probe"
figure 2.

!
2. Place the tip close to or on the shaft that
projects through the device's coil.

!
3. Observe the LED in the
handle.

!
4. If the LED is on,the solenoid or relay is
energized.

!
5. If the LED is off, the solenoid or relay is
de-energized.

!
6. If the LED turns on and off, and flow
through the solenoid valve under test is
not interrupted, or power through a
relay's contacts don't turn on and off, a
mechanical failure has occurred. 

!
7. If the LED remains off during machine
operation, two possible problems exist:!
A. No power to the solenoid or relay.!
B. An open coil

To locate the problem, first test the
power source, then the solenoid or
relay coil.

!
8. If transit pulses are suspected, hold the
Probe tip close to or on the solenoid or
relay and observe the LED during a
machine cycle. If transit pulses are
present during the time the solenoid or
relay should be off, the LED will flash on
and off.!
With a little practice, you'll know when to
use the high/low sensitivity ring in order to
test sub-miniature and smaller devices.!
!
If you need the added sensitivity, install the
high/low sensitivity ring according to the
following instructions.!
as shown in
"Mag-Probe's"

Advertisement

loading

Summary of Contents for Bartol Mag-Probe

  • Page 1 Replace the magnetic shield after relay’s contacts don’t turn on and off, a using.! mechanical failure has occurred. 
 DO NOT STORE THE “MAG-PROBE" NEAR A 7. If the LED remains off during machine PERMANENT MAGNET OR MAGNETIC FIELD.! operation, two possible problems exist:! “Mag-Probe"...
  • Page 2 “Mag-Probe’s" sensitivity range. ! 3. Continue sliding the ring toward the “Mag-Probe” body until the LED turns on and then off for the second time (See figure 5). Now the “Mag-Probe” is adjusted for high sensitivity. To be sure...
  • Page 3 TESTING DC POWERED DEVICES WITH THE HIGH/LOW SENSITIVITY RING INSTALLED ! When using the high/low sensitivity ring, the “Mag-probe” becomes sensitive to north and south poles. White dot toward the “Mag- Probe’s” tip detects North. When the ring is removed and installed with the white dot on the ring towards the “Mag-Probe’s”...