OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Description Description Features • Level controller for conducting liquids • Simultaneous monitoring of 4 levels • Two independent circuits for fill/empty • Indication of fill condition and operating status through 8 • Two high rating potential free relays with NO/NC contacts •...
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V General dangers and precautions Instructions regarding documentation Please carefully read the following instructions before putting into operation! The symbols used in the operating manual are to make you careful, before hand, regarding safety considerations and dangers. But, in no way, these symbols can substitute the text of the associated safety instructions.
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Description Functional description The control device is used for regulating level of conducting liquids like supply line water, rain water or condensate. The measurement of level in the reservoir is done with the help of electrodes, for which either contact surface of the reservoir walls or self made rod type electrodes can be used.
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Operating sequence diagram Initial condition : The reservoir is first empty. The electrode E1 is not in water contact. Relay 1 is in closed position (because of this e.g. the inlet valve is open). The water level rises in the reservoir. Water contact with the lower Electrode E1 (1) does not change the relay status and only when Electrode E2 comes into water contact (2), Relay 1 switches OFF (as an effect e.g.
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Scope of supply Die Lieferung des Geräts erfolgt inklusive Messfühler-Anschlusskabel, 6-polig mit RJ12 Steckverbinder, jedoch ohne Elektroden. Stan- dardfühler sind als Zubehör erhältlich oder können leicht selbst hergestellt werden. Die Lieferung der 12 V / 24 V Ausführung erfolgt als Modul (Platine) 95 x 75 mm ohne Gehäuse und ohne Bedienteil.
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V BETRIEBSART RELAIS 1 RELAIS 2 3.1.3 Operating voltage LEDS L PHASE N NULL PE (OPT) REL1 BOCKPOL REL1 SCHLIESSER REL1 ÖFFNER REL2 BOCKPOL REL2 SCHLIESSER REL2 ÖFFNER 230V AC model: The connection with mains power supply should be done by only trained and authorised persons. The electrical connection is done through the 9-pin plug connector as per pin configuration.
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Switching point adjustment The switching point is adjusted as per conductivity of water with the preset potentiometers. In normal practice, it is good enough to leave the potentiometer in the most sensitive position (left side limit).
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Connection of user‘s own sensors The following details are useful for persons with adequate knowledge of the associated electronics. The applicable safety regulations shall be duly followed! Connection and mounting operations shall be carried out only after switching off the voltage supply.
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Electrodes of stainless steel rods, hanged from top into the medium, are ideally suited for this purpose. The reference electrode is in the middle of the 4 diagonally arranged sensing electrodes which are placed in a span of approx. 1-5 cm. The spacing should be wide enough so that no drop of liquid sticks back to the rods when the level falls down.
OPERATION MANUAL Level controller for conducting liquits WLS-GEH230V Attention Please avoid extreme mechanical and inappropriate exposure. The device/product is not suitable for potential explosive areas and medical-technical applications. Technical changes reserved 11 / 11 0141 0316-112 20.04.2016...