M o d e l 2 0 0 9 M o d e l 2 0 0 9 6. COMPONENT ACCESSIBILITY ....................73 CONTENT 6.1 Electronics summary .......................74 6.1.1 Control unit ......................74 PREFACE .............................46 6.1.2 Interface / Display ....................75 6.1.3 Power supply ......................75 1.
M o d e l 2 0 0 9 M o d e l 2 0 0 9 1.1 Boiler System 1.6 Evaporation extractor system Turn on the device using the ON/OFF switch. The display will light up. Evaporation released during mixing is largely absorbed by the evaporation extractor ring (¿...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 2. MENU STRUCTURE 2.2 The operator menu 2.1 The operator/service menu Operator menu The majority of settings, including product settings, are protected by a PIN code. This PIN code Main item Sub item Item...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 2.3 The service menu Service menu continued …. Service menu Main item Sub item Item Range Description Main item Sub item Item Range Description 2.3 Recipe setting...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 Service menu continued …. Service menu continued… Set- Main item Sub item Item Range Description Main item Sub item Item Range Description ting 2.3 Recipe setting <Recipe name>...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 Service menu continued ….. Service menu continued ….. Set- Set- Main item Sub item Item Range Description Main item Sub item Item Range Description ting...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 Service menu continued…. Service menu continued…. Main item Sub item Range Description Main item Sub item Item Description 2.7 Hardware test Inputs Temperature Boiler temp °C 2.8 Read log...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 3. RECIPE SETTINGS PIN Code Table 3.1 Quick recipe Pincode Pincode First of all we would like to remind you that the cup volume (ml) and strength (%) can easily be set in the service menu 2.1 Quick recipe (page 52 of this document).
Page 11
M o d e l 2 0 0 9 M o d e l 2 0 0 9 OptiVend OptiVend 3 OptiVend 4 OptiVend 1 TS/TL OptiVend 2 TS OptiVend 3 TS OptiVend 4 TS Table 4 OptiVend 1 OptiVend 2 Table 5 Choco (Hot &...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 3.4 Detailed recipe settings To change detailed recipe settings (service menu 2.3) you ¿ rst need to be aware of the various parts OptiVend HS OptiVend HS OptiVend HS DUO...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 3.6 Principle overview 3.7 Calibrating the hot water valves OptiVend Choco The Mixers are supplied with water by the Dispensing OptiVend OptiVend OptiVend Valves DV1 and DV2.
¿ lter must be replaced. * User manuals, service manuals and software updates can be found on the Extranet section of www. animo.eu. If you do not have access, please request your personal login code on our website. Water hardness table Fig.
• Time: approximately 45 minutes Mixer(s) 10 min. • Animo Descaler x 2 sachets or 8-10 dessert spoons Check Motor axis for dirt and wear and tear. • Drip tray of approximately 1.5 litres Grease water connection using silicone grease).
M o d e l 2 0 0 9 M o d e l 2 0 0 9 6. COMPONENT ACCESSIBILITY 6. Pour the acid solution into the reservoir (¿ g. 8-1). Water reservoir The acid solution will now react with the lime scale. Dispensing valves 7.
During repairs or maintenance work, avoid electrostatic discharge (ESD) on the control unit. Main control board ......6.1.1 Optional Interface board ........6.1.2 Animo OptiVend Power supply 230Vac:24V 65W ..6.1.3 6.1.1 Main circuit board DISPLAY The main circuit board is accessible by removing the left side panel (¿...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 6.2 Main circuit board entrances 6.3 Main circuit board exits Connector J12 Connector J2 Connector cable between the main circuit and door circuit Motor Colour Comments...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 7.3 Troubleshooting 6.4 Main circuit board communication Communication Display Possible cause Action Conn Comments No action required. When boiler reaches When used for the ¿ rst time: boiler Coin tester NRI G13 the appropriate level, the display will show is still empty and is being ¿...
M o d e l 2 0 0 9 M o d e l 2 0 0 9 8. PAYMENT SYSTEMS Display Possible cause Action 8.1 Coin mechanism (optional) Valve exit overload (power too Out of order Check valves and wiring for leakage. high).
M o d e l 2 0 0 9 M o d e l 2 0 0 9 8.1.3 Activating existing tokens 8.1.6 Accepting Tokens only The token shown here (¿ g. 20) is programmed in Carry out sections 8.1.3 and 8.1.4 beforehand. the coin mechanism as standard.
M o d e l 2 0 0 9 M o d e l 2 0 0 9 8.2 Coin changer (optional) - Blanc - The OptiVend is available with an optional coin changer suitable for euros (€0.05 - €2.00). Other currencies are available on request.
Page 23
M o d e l 2 0 0 9 Animo B.V. Headof¿ ce Dr. A.F. Philipsweg 47 P.O. Box 71 9400 AB Assen The Netherlands Tel. no. +31 (0)592 376376 Fax no. +31 (0)592 341751 E-mail: info@animo.nl Internet: http://www.animo.eu Rev. 7.4 06/2011 Art.nr 09897...
Need help?
Do you have a question about the OPTIVEND 2009 and is the answer not in the manual?