RUNLUCKY SHOWER SOFTENER SHOWER SOFTENER Model:RL-R50/MYA-1 User Manual The appearance is just for reference. It is subject to the real product. Version 1 Please read this manual in details before using the product and keep it properly in order to consult in the future.
RUNLUCKY SHOWER SOFTENER Notice 1. If it is necessary to buy spare parts for installation, please select the parts with good quality. 2. The thread of the product is standard. When the ender user buys the matched accessories, please select it with good quality to prevent the accessories can’t be matched, thread cross, etc..
RUNLUCKY SHOWER SOFTENER 1. Product Overview 1.1. Characteristics ●Wall-mounted, no brine tank, small volume. ●Dynamic regeneration mode, bigger water treatment capacity, save salt and water. ●Extensive applicability: could be installed before or after the water heater. Installed before water heater could prevent it damaged because of scaling.
RUNLUCKY SHOWER SOFTENER 2. Installation 2.1. Installation Type Instruction There are two types of installation. A. Installed before water heater Advantage: Installed before water heater, the water flowing into water heater is soft which prevent the scaling and energy saving, as well as ensure the soft water for shower. It is suited for the user whose house is not decorated, could distribute the piping.
RUNLUCKY SHOWER SOFTENER 2.3. Pipeline Installation Instruction 2.3.1 Installed after Water Heater Remind: No water flows out when the shower softener in regeneration status (about 1 hour). If there is no spare faucet in the bathroom, it is suggested to have a spare outlet reserved when installation.
RUNLUCKY SHOWER SOFTENER b.If there is no spare faucet available in installation place and the ender user needs to use water in regeneration, it is suggest to have a spare outlet reserved on the outlet pipeline of water mixing valve.
Page 8
RUNLUCKY SHOWER SOFTENER Cut-off Optional Filter Valve 1/2〃Elbow Connector The following installation steps for installing before water heater 2.3.2.1.Install the cold and hot connector a.Shut off the source inlet water, remove the water mixing valve with a spanner, keep the original center distance of eccentric connector the same, as shown in Figure 10.
Page 9
RUNLUCKY SHOWER SOFTENER c.Use braided tube or corrugated pipeline to connect source inlet and inlet of shower softener. One outlet connects to inlet of water heater, the other outlet connects to cold water side of water mixing valve. As the product doesn’t have water flow out in regeneration process, a spare outlet is reserved when distribute the pipelines if needs to use water.
RUNLUCKY SHOWER SOFTENER 2.3.3. Drain Pipeline Installation The product has been installed drain pipeline in the factory. If the drain pipeline is needed longer, as sewer is far away or other reason, please use 1/4 "quick connector to connect the drain pipeline. Be sure the flow control in drain pipeline placed as shown in Figure 22.
RUNLUCKY SHOWER SOFTENER washing. 4.Regeneration Operation 4.1. Water Treatment Capacity Water treatment capacity relates to water hardness. For a family with 3 persons, if everyone uses 40L water for shower, calculate the regeneration time. Water Hardness Water Capacity Regeneration Time...
RUNLUCKY SHOWER SOFTENER regeneration button to switch it to water using status. Note: During the switching of regeneration process, there will be some water flowing out from outlet. Make sure the outlet of sprinkler not face to the shower softener.
Page 13
RUNLUCKY SHOWER SOFTENER 2. If the riser pipe falls out, it needs to be cleaned and inserted into resin tank. 3.Be sure the drain line flow control is undamaged when installing the drain pipeline.
RUNLUCKY SHOWER SOFTENER 6.Parameter Setting 6.1. Product Control Panel Instruction 7.2. Display Board Connector Instruction 6.3. Product Installation Type Setting There are two types of instalation, which are installed before and after water heater. It has difference processes accordingly. Resin invalid warning has time clock type and meter type. (Currently, it only has time clock type.
RUNLUCKY SHOWER SOFTENER Installed after water heater, installation type selection, press to select meter type Installed before water the type, then press to save the setting heater, meter type and quit. Enquiry mode:Power on, interface will display installation type. 6.4. Regeneration Days Reminding Settings The shower softener can be set up alarm of regeneration days according to the practical circumstance.
8. Warranty Card Dear client: This warranty card is the guarantee proof of RUNLUCKY Shower Softener. It is kept by client self. You could get the after-sales services from the supplier which is appointed by RUNLUCKY manufacturer. Please keep it properly. It couldn’t be retrieved if lost. It couldn’t be repaired free of charge under the below conditions: 1.Guarantee period expired.(One year);...