Page 1
ECI 1000-U LCD Installation Manual REV : 1.0 DATE: 4/13/2018 MANUAL NUMBER : 33 ELECTRONIC CONTROLS, INC. | 7073 NORTH ATLANTIC AVE CAPE CANAVERAL, FL 32920 WWW.ECIAMERICA.COM 800-633-9788...
Page 2
ECI 1000-U LCD Installation Manual DATE DESCRIPTION 9/3/2015 Preliminary release for review 10/22/2015 Changed to ECI 1000-U Changed Table 1 – LED STATUS 3/28/2016 3/30/2016 Added illustrations for X7,X8,X10 4/13/2018 Added new logo Electronic Controls, Inc. 7073 North Atlantic Ave. Cape Canaveral, FL 32920 800-633-9788 www.eciamerica.com...
Replacing the ECI Canada ECI-1001-1300 with ECI 1000U LCD ..........12 Replacing the ECI Canada ECI-1000-500 with ECI 1000U LCD board ........12 Replacing the ECI Canada ECI-1000-1400 with the ECI 1000U LCD board ......13 Initial Power up and Adjustments ....................... 13 Electronic Controls, Inc.
Page 4
ECI 1000-U LCD Installation Manual Testing Operation ........................13 Door Adjustments ........................14 8.2.1 Adjustment Notes ........................ 14 8.2.2 Door Speed Adjustments ....................14 8.2.3 Heavy Door Adjustment ..................... 14 8.2.4 Door Closing Force Adjust ....................15 RUN Operation ........................... 15 Trouble Shooting ..........................
ECI 1000-U LCD Installation Manual 1 Warning and Disclaimer Thank you for purchasing equipment from ECI America, INC. We want your new equipment to operate safely. Anyone who installs or uses this equipment should read this publication (and any other relevant publications) before installing or operating the equipment.
ECI 1000-U LCD Installation Manual When you see the “exclamation point” icon in the left hand margin the paragraph to its right will be a warning. The information could prevent injury, loss of property, or even death in extreme cases. Any waring in this document should be regarded as critical information that should be read in its entirety.
ECI 1000-U LCD Installation Manual 5 Introduction This manual is intended to help facilitate the installation of ECI 1000U LCD Door Operator board made by Electronic Controls, Inc. The audience of the material included in this manual is for the certified installation personnel.
ECI 1000-U LCD Installation Manual 6.2.3 X13 Controller interface The voltage of controller interface signals are adjustable through the Input Voltage parameter located under the Edit Parameters menu. These signals are AC/DC compatible. DO3 – Open limit output to controller DO10 –...
ECI 1000-U LCD Installation Manual 6.3 User Interface 6.3.1 Toggle switches Run/Test – Two position switch. In RUN position the door board is controlled through the controller interface. In the TEST position door operation is controlled through the OPEN/CLOSE switch.
ECI 1000-U LCD Installation Manual Figure 1 - Main Menu shows the top 4 items of the main menu. Pressing the “-“ button moves the curser/hi-light down to reveal other menu options Edit parameters – Pressing ENTER with the Edit Parameters hi-lighted will enter the parameters menu.
ECI 1000-U LCD Installation Manual 6.3.5.2 Parameter settings and defaults CF – Close Fast Speed – Default setting is 60. Range is 1-100 CS – Close Slow Speed – Default setting is 20. Range is 1-100 SS – Close slow start – Default setting is 20. Range 1-100.
2. Remove cover to access door board. 3. Unplug connectors from existing board. 4. Disconnect L1A and L2A from existing board and connect to X12 (2 pin connector) for the ECI 1000U LCD board. 5. Disconnect all wires from J2 (old board) and connect to X13 (7 pin connector) for ECI 1000U LCD board: DO3, DO10, D07, D04, DO18, DO17.
13. Connect the ORANGE wire from the + terminal of the rectifier to 54P pin of the 6 pin connector for the ECI 1000U LCD board. 14. Install the ECI 1000U LCD board and connect 4 pin MOLEX connector to X1 for F1, 16V1, 16V2, L1A.
ECI 1000-U LCD Installation Manual a. The doors should start moving and the DRIVE and MOTOR reading in the DIAGNOSTICS menu should increase. If the doors do not move refer to section ?????? b. When the doors are fully open the DRIVE and MOTOR readings should go to 0 and the OL LED should light 6.
ECI 1000-U LCD Installation Manual NOTE: The heavy door closing speed must be set slower than a standard door to comply kinetic energy requirements set by the Elevator Codes. NOTE: Must press ESC button to save all changes into permanent memory. Failing to do so will result in parameters reverting to default settings in the event of a power loss.
Page 16
ECI 1000-U LCD Installation Manual Figure 4 – Speed Profiles Figure 5 – CAM Switch Wiring Electronic Controls, Inc. 7073 North Atlantic Ave. Cape Canaveral, FL 32920 800-633-9788 www.eciamerica.com P a g e | 16...
Page 17
ECI 1000-U LCD Installation Manual LINK 24B2 DO10 DO18 DO17 Figure 6 – ECI 1000-U Electronic Controls, Inc. 7073 North Atlantic Ave. Cape Canaveral, FL 32920 800-633-9788 www.eciamerica.com P a g e | 17...
ECI 1000-U LCD Installation Manual 9 Trouble Shooting LED STATUS OPERATION OSDL CSDL HDCSDL DO18 DO10 DO17 Door Closed Door open Door locked Heavy Door Closed Doors Closing Doors Closing Nudging Doors Opening Table 1- LED Status * LED will change state during operation ** On if heavy door Electronic Controls, Inc.