Hide thumbs Also See for PUSH:
Table of Contents

Advertisement

Quick Links

Sistemi Elettronici
di Apertura Porte e Cancelli
INTRODUCTION.........................................................................................................................................................30
FEATURES..................................................................................................................................................................30
SPECIFICATIONS.......................................................................................................................................................30
INSTALLATION............................................................................................................................................................31
Precautions......................................................................................................................................................31
Package Contents............................................................................................................................................31
CONNECTION TERMINALS.......................................................................................................................................31
The On-Board LED Indicators...........................................................................................................................33
The Pacier Tones & The LED Signals................................................................................................................33
The Jumper for Back-Lit Selection....................................................................................................................33
FEATURE PROGRAMMING & OPERATION INSTRUCTIONS...................................................................................34
Set System in Programming Mode with The Master Code.................................................................................34
The Default Values of The Keypad....................................................................................................................35
KEYPAD PROGRAMMING MAKE SIMPLE - For General Users.................................................................................36
FEATURE PROGRAMMING -- KEY IN AND STORE THE DESIRED VALUES.............................................................37
Programming Criteria for Codes.......................................................................................................................37
Record A Master Code......................................................................................................................................38
Record A Super User PIN..................................................................................................................................38
Operation And Functions of The Super User PIN...................................................................................38
Examples - Programming And Operation.............................................................................................39
Visitor Codes (For Output 1 Only).....................................................................................................................41
Duress Codes (For Outputs 1, 2 & 3).................................................................................................................42
The Operation And Function of The Duress Code.................................................................................43
Conguration of The Output Modes for Output 1, 2 And 3....................................................................................43
Personal Safety And System Lock-Out.............................................................................................................43
User PIN Entry Mode........................................................................................................................................44
Pacier Tones On-Off Selection..........................................................................................................................44
Output Operation Announcer............................................................................................................................44
Status LED Flashing On-Off during Standby......................................................................................................45
Door Forced Open Warning & Timing................................................................................................................45
Door Propped-Up Warning & The Delay Time...................................................................................................45
Intelligent Egress Button - An Unique Feature of A Contemporary Keypad........................................................46
Egress Delay , Warning And Alarm....................................................................................................................46
Congurations of The Egress Warning And Alarm...................................................................................46
Door Opening Alarm & Timer.............................................................................................................................47
Close The Programming Mode.........................................................................................................................48
PROGRAMMING SUMMARY CHART.........................................................................................................................48
APPLICATION EXAMPLES.........................................................................................................................................50
Basic Wirings of A Stand Alone Door Lock.........................................................................................................50
Basic Wirings of A Stand Alone Door Lock with Inhibit Authorization Code.........................................................51
Basic Wirings of An Inter-Lock System Using Two Keypads..............................................................................52
APPLICATION HINTS FOR THE AUXILIARY TERMINALS..........................................................................................53
APPENDIX...................................................................................................................................................................55
67411245
®

TABLE OF CONTENTS

Rev. 01 - 05/2011
PUSH
English
29

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PUSH and is the answer not in the manual?

Questions and answers

Summary of Contents for SEA PUSH

  • Page 1: Table Of Contents

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 TABLE OF CONTENTS INTRODUCTION.................................30 FEATURES..................................30 SPECIFICATIONS...............................30 INSTALLATION................................31 Precautions..............................31 Package Contents............................31 CONNECTION TERMINALS............................31 The On-Board LED Indicators...........................33 The Pacier Tones & The LED Signals........................33 The Jumper for Back-Lit Selection........................33 FEATURE PROGRAMMING &...
  • Page 2: Introduction

    It is an ideal keypad mainly for Door Strike and Alarm Arm-disarm control. It is also a programmable industrial timer (with the timing of 1 second to over 24 hours) for Automatic Operator Systems. PUSH – Output Relays for Output 1, 2 and 3 (Surface Mount Version) FEATURES •...
  • Page 3: Installation

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 INSTALLATION PRECAUTIONS Please be patient to study the manual to become familiar with the specications of the system before starting the installations. 1) Do not apply power to the system while it is in installation.
  • Page 4 ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 • 6 - 7 - 8 : OUTPUT 2 (Output Relay 2) 1 Amp relay dry contact controlled by the Group 2 User PINs for Output 2, it is an auxiliary output ideally for controlling security system or automatic operator.
  • Page 5: The On-Board Led Indicators

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 • 18 : INTER-LOCK O/P (Inter-lock Control Output) An NPN transistor open collector output with the maximum power rating of 24VDC/100mA sink. It is OFF at normal condition and it switches to (-) ground immediately for the first 5 seconds after keying in a valid User PIN to operate Output 1, then, it will keep tying to (-) ground during the Door Position Sensor is open circuit due to door opening.
  • Page 6: Feature Programming & Operation Instructions

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 FEATURE PROGRAMMING & OPERATION INSTRUCTIONS SET SYSTEM INTO PROGRAMMING MODE WITH THE MASTER CODE IMPORTANT NOTE: 1) DO NOT TURN OFF POWER while the keypad is in Programming Mode. Otherwise, it may cause data lost/error programmed features in the memory.
  • Page 7: Refresh The System With The "Refreshing Code

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 REFRESH THE SYSTEM WITH THE “REFRESHING CODE ” - - - 9999 The system can be refreshed to clear all the old data stored and back to its ex-factory default values.
  • Page 8: Keypad Programming Make Simple - For General Users

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 KEYPAD PROGRAMMING MAKE SIMPLE – FOR GENERAL USERS This is a multi purpose keypad. It has many functions for user’s selection. For those general users taking the keypad for door strike only, most of the features can be kept in their Default values.
  • Page 9: Feature Programming -- Key In And Store The Desired Values

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 FEATURE PROGRAMMING - - KEY IN AND STORE THE DESIRED VALUES The feature values can be set and stored into the system one by one with the desired Programming Locations.
  • Page 10: Record A Master Code

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 RECOR A MASTER CODE ( Location 01) LOCATION MASTER CODE VALIDATION 8 Digits MASTER CODE • Master Code is the authorization code for setting the system to programming mode. It is NOT an User Code operating of the output relays.
  • Page 11: Record-Delete Pins For Output 1, 2, & 3

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 RECORD - DELETE USER PINS FOR OUTPUT 1 , 2 , & 3 ( Locations 10 , 20 & 30) Total of 1,200 User PINs are available for the 3 user groups to control the 3 outputs.
  • Page 12 ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 2) Example 2 -- User PIN for Output 2 : i) Programming : 1234 ( c) (a) The User PIN is programmed for Output 2...
  • Page 13: Visitor Codes (For Output 1 Only)

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 VISITOR CODES (FOR OUTPUT 1 ONLY) ( Location 40) The Visitor Codes are the temporary user codes for operating of the Output 1 (mainly for door strike in access control).
  • Page 14: Duress Codes (For Outputs 1, 2 & 3)

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 DURESS CODES (FOR OUTPUTS 1, 2 & 3) (Location 41, 42 & 43) The Duress Codes are prepared for those Important Persons in case of DURESS while he operates the access control keypad.
  • Page 15: The Operation And Function Of The Duress Code

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 THE OPERATION AND FUNCTION OF THE DURESS CODE The Duress Code(s) has double actions when it is keyed in. It activates the Duress Output (for duress alarm) and at the same time activates the speficic Relay Output 1, 2 or 3 just like a normal User PIN.
  • Page 16: User Pin Entry Mode

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 5 - 10 ---Selection of after 5 to 10 successive User Code trials, the keypad locks during 15 minutes. The keypad can be reset to release the lock-out with the “Super User Code” in the following way.
  • Page 17: Status Led Flashing On-Off During Standby

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 0 --- 2 Short Beeps Notication 2 short beeps notication is given when the output is activated with a valid Code. STATUS LED FLASHING ON - OFF DURINGSTAND BY...
  • Page 18: Intelligent Egress Button - An Unique Feature Of A Contemporary Keypad

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 INTELLIGENT EGRESS BUTTON – AN UNIQUE FEATURE OF A CONTEMPORARY KEYPAD Most of the keypads for access control are just for controlling of “Going In” from outside. It is not enough for today’s access control systems.
  • Page 19: Door Opening Alarm & Timer

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 Output 1 activates instantly (the door is released instantly) when the Egress Button is pressed. 1 – 99 --- E gress Delay Timing Put any number of 1 to 99 into the box to enable the Egress Delay. The number is the time in second, which starts to count when the Egress Button is pressed.
  • Page 20: Close The Programming Mode

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 The Manner of The Door Opening Alarm: a) The door is forced to open without using PIN – Alarm b) The door is opened with Egress Button – Alarm c) The door is opened with PIN –...
  • Page 21 ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 LOCK-OUT CODE: 1---10 Trial, Lock-out 60 Sec. Code = 1, 2---10 Trial, Activates Duress Personal Safety & 10 Trials, 5-10---5-10 Trial, Lock-Out 60 LOCK-OUT CODE #...
  • Page 22: Application Examples

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 DAP CODE-- Direct access to programming mode. Valid 8080 8080 # System in Programming Mode only in the power-up delay Period USER PINs / Codes whole...
  • Page 23: Basic Wirings Of A Stand Alone Door Lock With Inhibit Authorization Code

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 2) BASIC WIRINGS OF A STAND ALONE DOOR LOCK WITH INHIBIT AUTHORIZATION CODE • Use output 3 as authorization control. The owner may key in the user code 3 to stop the operation of the electric lock in the night time or after office hour to prevent unauthorized access.
  • Page 24: Basic Wirings Of An Inter-Lock System Using Two Keypads

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 3) BASIC WIRINGS OF AN INTER-LOCK SYSTEM USING TWO KEYPADS An inter-lock system needs two door controllers. This application example uses two keypads with simple cross wire connection on their "Output 1 Inhibit"...
  • Page 25: Application Hints For The Auxiliary Terminals

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 APPLICATION HINTS FOR THE AUXILIARY TERMINALS (A) TAMPER N.C. The tamper switch is Normally Closed while the keypad is secured on gang box. It is open when the keypad is removed from the gang box.
  • Page 26 ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 (D) KEY ACTIVE -- SET THE "K OR A" JUMPER TO "K” • Only one connection option is recommended. Make The Key Active Output switches to (-) ground for 10 sure the sink current does not exceed the maximum seconds whenever a key is touched.
  • Page 27: Appendix

    ® PUSH English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n. 804888 (F) OUTPUT 2 ( i ) Shunting an N.C. Zone • Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone of an alarm system.

Table of Contents