iceqube IQ700HE Operation And Installation Manual

Heat exchangers, class i division 2 groups a, b, c, & d hazardous locations or nonhazardous locations

Advertisement

Heat Exchangers
Class I Division 2 Groups A, B, C, & D Hazardous Locations or Nonhazardous Locations
OPERATION AND INSTALLATION MANUAL
*** IMPORTANT ***
PLEASE READ this manual and follow the instructions for safe and satisfactory installation and operation of this system. Keep
this manual for future reference. Some information may not apply to
all systems.

Advertisement

Table of Contents
loading

Summary of Contents for iceqube IQ700HE

  • Page 1 Heat Exchangers Class I Division 2 Groups A, B, C, & D Hazardous Locations or Nonhazardous Locations OPERATION AND INSTALLATION MANUAL *** IMPORTANT *** PLEASE READ this manual and follow the instructions for safe and satisfactory installation and operation of this system. Keep this manual for future reference.
  • Page 2: Table Of Contents

    Fan Speed Controller (Ord Loc Only) ................9 Maintenance ........................11 Trouble Shooting ......................11 Schematic/Wiring Diagram.................... 13 Specification Drawings ....................14 IQ700HE ........................14 IQ800HE ........................15 IQ900HE ........................16 IQ2200HE ........................17 IQ6100HE ........................18 IQ7400HE ........................19 IQ10000HE ........................
  • Page 3: Introduction

    Introduction Ice Qube computer and electronics enclosure cooling systems have been designed to provide a safe environment for your equipment. Our cooling systems provide this environment by cooling the enclosure that houses your equipment while providing an efficient, modern, and aesthetically pleasing package requiring minimal maintenance.
  • Page 4: Preservation Instructions

    Preservation Instructions Unpacking Inspection Caution: It is recommended using gloves and protective eyewear when unpacking Verify product is as identified on the packing list. Any evidence of damage should be noted on the freight bill. The freight carriers claim procedure should be followed. Ice Qube cannot accept responsibility for damages that occur during shipping.
  • Page 5: Pre-Installation Test

    Ice Qube TMS. An Electronic copy is available at http://www.iceqube.com/downloads/specification-drawings/ Ensure the Ice Qube TMS will be mounted level. Ensure the inlet and outlet of the cold air stream will not be restricted by equipment or shelving within your enclosure.
  • Page 6: Mechanical Installation Instruction

    Confirm the gasket is properly installed to the Ice Qube TMS. This gasket is required to create a seal against your enclosure and will maintain enclosure integrity. (See Gasket and Cutouts pg 21) Mechanical Installation Instruction Caution: Protective safety clothing such as helmet, gloves, and steel toe shoes are recommended. Position the Ice Qube TMS so that the two mounting studs are in alignment with the top two 3/8”...
  • Page 7: Electrical Installation Instruction

    Electrical Installation Instruction Please read the entire section before beginning the electrical installation of the Ice Qube TMS. Ice Qube heat exchangers have been designed for easy electrical power connection at one specific location on the enclosure side of the Ice Qube TMS. Each Ice Qube TMS been designed to operate at a range of voltages and frequencies.
  • Page 8 Figure 3: Terminal Cover Figure 4: Terminal Block (optional) Rev. 6...
  • Page 9: Operating Your System

    *Verify voltage with model* Figure 5: Power Terminal Block (optional) Operating Your System Once the Ice Qube TMS has been installed onto the enclosure and the power cable has been attached to a properly grounded electrical connection with adequate voltage and current supply, the unit is ready for operation.
  • Page 10 FAN 2 tests just as FAN 1. Pause for 3 seconds. FAN 1 and 2 test simultaneously as above. Pause for 3 seconds. ALARM relay activates for 3 seconds. Then system returns to normal operation. Operation The Ice Qube fan speed controller has two adjustable set points, one for the ambient fan and one for the enclosure fan.
  • Page 11: Maintenance

    Rinse with clean water. Use a shop-vac to remove excess water from the filter before returning it to the system. Replace the filter if it shows signs of deterioration. See website for air filter cleaning demonstration at http://www.iceqube.com/ice-qube-tv/. Cooling System Cabinet: The heat exchanger cabinet may also need to be cleaned occasionally.
  • Page 12 Trouble Shooting Checklist Serial Model No: Number: Voltage Rating: Amps: Phase: Frequency: Options: Yes  No  Is proper electrical power available at the power supply? Yes  No  Is your power cord connected to the power supply and IQ terminal block? Yes ...
  • Page 13: Schematic/Wiring Diagram

    Schematic/Wiring Diagram Figure 6...
  • Page 14: Specification Drawings

    Specification Drawings IQ700HE Figure 7 Rev. 6...
  • Page 15: Iq800He

    IQ800HE Figure 8 Rev. 6...
  • Page 16: Iq900He

    IQ900HE Figure 9 Rev. 6...
  • Page 17: Iq2200He

    IQ2200HE Figure 10 Rev. 6...
  • Page 18: Iq6100He

    IQ6100HE Figure 11 Rev. 6...
  • Page 19: Iq7400He

    IQ7400HE Figure 12 Rev. 6...
  • Page 20: Iq10000He

    IQ10000HE Figure 13 Rev. 6...
  • Page 21: Gasket And Cutouts

    Gasket and Cutouts IQ700-800HE Gasket and Cutout Same Gasket and Cutout for IQ700HE, and IQ800HE Figure 14 Rev. 6...
  • Page 22: Iq900He Gasket And Cutout

    IQ900HE Gasket and Cutout Figure 15 Rev. 6...
  • Page 23: Iq2200He Gasket And Cutout

    IQ2200HE Gasket and Cutout Figure 16 Rev. 6...
  • Page 24: Iq6100He Gasket And Cutout

    IQ6100HE Gasket and Cutout Figure 17 Rev. 6...
  • Page 25: Iq7400He Gasket And Cutout

    IQ7400HE Gasket and Cutout Figure 18 Rev. 6...
  • Page 26: Iq10000He Gasket And Cutout

    IQ10000HE Gasket and Cutout Figure 19 Rev. 6...
  • Page 27 Standard Warranty Policy Ice Qube, Inc. ("Ice Qube") warrants that the products manufactured by Ice Qube (the "Products") are free of defects in material and workmanship which impair the operation of the Products, under normal and proper use and service, for a period of one (1) year from the date of shipment FCA from Ice Qube’s facility located in Greensburg, Pennsylvania (the "Standard Warranty").
  • Page 28  fire, wind, hail, flood, lightning or other acts of God;  any damage to the finish of the Products after they leave Ice Qube's facility;  any discoloration or spotty appearance of the Products;  return freight and shipping charges, along with applicable duties and other like fees and charges, for the return of the Product to Ice Qube (such amounts are the sole responsibility of the customer);...
  • Page 29: Notes

    Notes: Rev. 6...

Table of Contents