Connect
Installation Guide
ECN-Lx
ECN-L9
Applications
• Replace RS-485 and RS-232 cable
• Overcome the cabling limitation in toughenvironment
• Extend the signal transmission distance of RS232 and RS485
• Easy installation will cost down and speed up the systemsetup
• Avoid the fix cable being damaged by weather or wild animal in out door
ACT POWER TAIWAN CO., Ltd.
2017 ACT POWER All right reserved
www.actpower.com.tw

Advertisement

loading

Summary of Contents for ACT POWER EASYCON Connect ECN-L Series

  • Page 1 • Extend the signal transmission distance of RS232 and RS485 • Easy installation will cost down and speed up the systemsetup • Avoid the fix cable being damaged by weather or wild animal in out door ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 2: Table Of Contents

    RS-232 cable, or want to prevent cable damaged in out door, etc. Index 1. Unpacking 2. Overview P2-P3 3. Dip Switch Setting 4. Engineering Mode P5-P6 5. ID-Mode 6. T-Mode 7. System Structure ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 3: Unpacking

    2 Pole, 3.5mm *1, 3 Pole, 3.5mm *1,Phoenix Connector Overview ECN-L9 Installation Guide < Front > Signal receiving (Rx) status indicator Signal transmission (Tx) status indicator Power status indicator ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 4 • DB-9 Connector for RS-232 cable which connect to equipment or computer • Phoenix Connector for 12V DC powerinput • Connect the power cable to the 2-Pole 3.5mm Phoenix Female Connector first ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 5: Dip Switch Setting

    S3-Freq. (1,2,3) Frequency selection (0,0,0) 922.4MHz (0,0,1) 924.8 MHz (1,0,0) 923 MHz (1,0,1) 925.4 MHz (0,1,0) 923.6 MHz (0,1,1) 926 MHz (1,1,0) 924.2 MHz (1,1,1) 926.6 MHz - 4 - ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 6: Engineering Mode

    XX XX XX XX XX XX XX XX Device ID Firmware Version 00~FF hexadecimal continuous number to check if there any data lost during transmission Signal strength (RSSI 17~-125 )* ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 7: Id-Mode

    6. Check front LED indicator on ECN-Lx, it will blink while transmitting or receiving the data * Sometimes you will need to use NULL Modem (It isn’t included in the shipment) to connect ECN-Lx and equipment ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 8: T-Mode P7

    6. Check front LED indicator on ECN-Lx, it will blink while transmitting or receiving the data * Sometimes you will need to use NULL Modem (It isn’t included in the shipment) to connect ECN-Lx and equipment ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 9: System Structure

    System Structure ECN-Lx InstallationGuide Point to Point Topology Star Topology All specifications are subject to change without notice ACT POWER TAIWAN CO., Ltd. 2017 ACT POWER All right reserved www.actpower.com.tw...
  • Page 10 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.