To program a new remote for the Maximum Controls MAX 1500 PRO using the WEL-200 system:
1. Install 2 AA Lithium batteries in the WEL-200T transmitter. The green LED will flash twice every two seconds. 2. Install a properly terminated edge (8.2k or 10k) to the transmitter. 3. On the WEL-200R receiver, press and hold the desired channel assignment switch until all four LEDs flash, indicating programming mode.
This pairs the transmitter (remote) with the receiver for gate control.
This answer is automatically generated
Summary of Contents for Maximum Controls MATRIX III MAX 1500 PRO
Page 1
Installation Guide for MAX 1500 PRO/2200 PRO/f18 PRO Slide Gate Operators MATRIX III CONFORMS TO UL STD 325 CONFORMS TO UL STD 325 MAX 1500 PRO/2200 PRO UL CLASS - I, II, III, IV SAFETY SENSORS REQUIRED MAX F18 PRO UL CLASS - III, IV ONLY CERTIFIED TO CAN/CSA STD C22.2 NO.
Page 2
ul 325 compliant installation requirements Safety - 1...
Page 5
ul 325 model classifications AUTHORIZED PERSONNEL ONLY CLASS I CLASS III Residential Vehicular Gate Operator Industrial/Limited Access Vehicular Gate Operator SECURITY CLASS II CLASS IV Commercial/General Access Vehicular Gate Operator Restricted Access Vehicular Gate Operator ul 325 required entrapment protection Gate Type Class I &...
Page 6
intended use of slide gate operator VEHICULAR WITH MUST OPENING Direction Reverse Edge: Gate Pickets: LESS Wire Mesh: MORE Warning Signs: BOTH Guide Rollers: CLOSING Direction Reverse Edge: OPENING Direction Reverse Edge: CLOSING Direction Photocell: r i o w it p ri th e t le...
Page 7
Table of Contents Additional Features Gate Safety Page Step-By-Step Installation Troubleshooting Commonly Used Safety Sensors Wiring Overview Optional Magnet Limit Sensors Optional Solar Power specifications UL 325 Class of Operation MAX 1500 PRO/2200 PRO MAX F18 PRO Class III, IV ONLY. MUST Gate Type EACH...
Page 8
step-by-step installation Choose either Front Mounting Position (Standard) or Rear Mounting Position (Alternate). Operator Placement (standard) Operator in Front Position (Standard) Conduit Guidelines and Suggestions • REQUIRED - • REQUIRED - OPENING CLOSING • Conduit UL 325 2018 Standard Area Operator Position on BOTH...
Page 9
connect chain to gate (standard) Top View of Operator IMPORTANT: MUST BOTH NOTE: IMPORTANT: MUST without binding Back View of Operator MUST NOTE: Do not over tighten the chain. 13.5” 13.5” 6” Operator in Front Position (Standard)
Page 10
rear mounting position (alternate) Conduit Guidelines and Suggestions • REQUIRED - • REQUIRED - OPENING CLOSING Conduit • Area UL 325 2018 Standard 24” BOTH MUST 24” Operator Position on Concrete Pad Operator in Rear Position OPEN ONLY NC MUST Operator MUST be level.
Page 11
connect chain to gate (rear pos) Top View of Operator IMPORTANT: MUST NOTE: BOTH MUST MUST Operator in Rear Position Back View of Operator IMPORTANT: MUST NOTE: Do not over tighten the chain. without binding MUST MUST 22.5” 10.5” 6” Modify Cover for Rear Mounting Position 16.5”...
Page 12
ac input power Choose either 115V or 230V setting on input AC power selector switch. Wire desired input AC power wire to power terminal. A additional single gang box is provided t I n l e c l t a CAUTION: Make sure circuit breaker is OFF from incoming...
Page 13
ground operator Operator MUST be Properly GROUNDED IMPORTANT: VOIDED! WARNING connect chassis to ground rod for lightning protection ul e M od Er ro TE ST pl ac /O FF 1/ 2 Proper grounding of this gate operator is a requirement for LIGHTNING PROTECTION in lightning prone areas.
Page 14
entrapment protection wiring LEFT RIGHT LOCK Normally Closed Photocells MAGLOCK Bi-Parting Gates NOTE: DELAY Factory Learned Input sensors to EITHER OPEN ONLY Factory Learned Input Opening Direction - PHOTO CLS 2.5 sec OPEN/CLS does NOT 1.5 sec 10K Sensing Edges 12VDC OUT monitored 12VDC OUT Closing Direction -...
Page 15
continued Entrapment Protection Device Options and Locations: The following is a list of recommended accessories for Sensing Edges WIRELESS NOTE: the MAX Slide PRO Operators. IMPORTANT: MUST need to be installed on EACH Self-Supporting Post OPENING and CLOSING L- TX M on G at re d...
Page 16
BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR MOTOR BATTERY BATTERY INPUT INPUTS BACKUP MODE BATTERY LEAVE OPEN IN USE program virtual limit sensors OPEN 1 TIME REPLACE LEAVE BATTERY MOTOR BATTERY POWER / CLOSED TEST POSITION POWER SOLAR IN INPUTS CLOSE ERD SENSITIVITY TIMER...
Page 17
learn gate positions EACH CLOSED IMPORTANT: GATE SHUT-OFF MUST MOTION CONTROL GATE SPEED OPEN OPEN STOP CLOSE OPENING CLOSING MOTION CONTROL CLOSE CLOSE OPEN STOP Gate positions have now been learned. “GATE SPEED” Adjust ERD Reverse sensor CAUTION: Keep pedestrians and vehicles clear of the gate while adjusting sensors. ERD Sensor Electronic Reversing Device MUST OPEN and CLOSE gate cycles...
Page 18
TEST POWER SOLAR IN ERD SENS loops & loop detectors MOTOR MODULE SENSE OVER PORT LOAD OPENING OBD PORT RESET / BLACK BOX MANUAL RELEASE SWIN External Loop Detectors ALARM e r n E x t PROGRAMMING ID PLUG ERROR t o r t e c Loop Detector Rack...
Page 19
wiring opening device options BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR MOTOR BATTERY BATTERY INPUT INPUTS BACKUP MODE BATTERY LEAVE OPEN IN USE OPEN 1 TIME Maglock REPLACE LEAVE BATTERY MOTOR BATTERY POWER / CLOSED TEST POSITION POWER SOLAR IN INPUTS CLOSE ERD SENSITIVITY...
additional features programming MOTION CONTROL BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR MOTOR BATTERY BATTERY INPUT INPUTS NPUTS BACKUP MODE BATTERY LEAVE OPEN IN USE OPEN 1 TIME REPLACE LEFT RIGHT LEAVE BATTERY MOTOR MOTOR OPEN CLOSE BATTERY STOP POWER / CLOSED TEST POSITION...
Page 21
gate shut-off switch IMPORTANT: “BEEP” Gate Shut-Off Switch LEFT RIGHT Jog Left Jog Right TECHNICIAN MAINTENANCE TIP: Gate Shut-Off switch only Gate Shut-Off Electronic Gate OPEN / CLosE owner HOLD...
Page 22
gate tamper feature GATE TAMPER MUST be ARMED Wiring Gate Tamper BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR MOTOR BATTERY BATTERY INPUT INPUTS BACKUP MODE BATTERY GATE TAMPER LEAVE OPEN IN USE OPEN 1 TIME REPLACE LEAVE BATTERY MOTOR BATTERY POWER / CLOSED TEST...
Page 23
Partial open programming Dropping the Chain - GATE TAMPER is ARMED (ON) BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR BATTERY MOTOR BATTERY INPUT INPUTS BACKUP MODE BATTERY LEAVE OPEN IN USE OPEN 1 TIME REPLACE LEAVE BATTERY MOTOR BATTERY POWER / CLOSED TEST POSITION...
Page 24
dual gate operators wiring Primary Operator Secondary Operator Set one operator to PRIMARY and the other to SECONDARY. BATTERY MATRIX III BATTERY MATRIX III BATTERY VOLTAGE BATTERY VOLTAGE INPUT INPUT Set opening directions of each (reverse of each other). ERROR ERROR BATTERY MOTOR...
Page 25
gate disable feature GATE DISABLE • • GATE DISABLE GATE DISABLE GATE DISABLE IMPORTANT: It is NOT GATE DISABLE BATTERY MATRIX III Wiring Gate Disable BATTERY VOLTAGE INPUT ERROR BATTERY MOTOR BATTERY INPUT BACKUP MODE INPUTS BATTERY LEAVE OPEN IN USE OPEN 1 TIME GATE DISABLE...
troubleshooting This page and the next 3 pages can help troubleshoot problems that might occur after installation is complete. usb black box port Event History Text Document Sample a r t INFO: BATTERY MATRIX III WARNING: P h o BATTERY VOLTAGE ERROR: INPUT ERROR...
Page 27
gate cycling troubleshooting Use this table to help with troubleshooting AND operator LED troubleshooting on the next 2 pages. Gate Symptom Solutions (what to check)
Page 28
matrix III led troubleshooting BATTERY MATRIX III BATTERY INPUT ERROR BATTERY VOLTAGE INPUT ERROR MOTOR BATTERY IN USE BATTERY BATTERY INPUT INPUTS BACKUP MODE BATTERY VOLTAGE BATTERY LEAVE OPEN IN USE OPEN 1 TIME REPLACE BATTERY REPLACE LEAVE BATTERY MOTOR CLOSE TIMER BATTERY POWER...
Page 29
matrix III led continued Matrix III LED Normal Solution(s) for Problem Condition Problem Condition 18 or 19...
Page 30
omron E3K-R10K4 wiring for max pro UL325-2018 UL325-2018 NORMALLY CLOSED (NC) NORMALLY CLOSED (NC) Wiring to E3K Photocell Wiring to E3K Photocell OPENING Direction CLOSING Direction Photocell (Reflector) Photocell (Reflector) UL 2018 Label on packaging UL 2018 Label on packaging NOTE: To meet the UL 325 2018 standard, NOTE: To meet the UL 325 2018 standard, Type B1 Non-Contact sensor entrapment...
Page 31
omron E3K-R10K4 wiring for max pro UL325-2016 UL325-2016 UL325-2016 UL325-2016 NORMALLY CLOSED (NC) NORMALLY CLOSED (NC) NORMALLY CLOSED (NC) NORMALLY CLOSED (NC) Wiring to E3K Photocell Wiring to E3K Photocell Wiring to E3K Photocell Wiring to E3K Photocell OPENING Direction CLOSING Direction Photocell (Reflector) Photocell (Reflector)
Page 32
omron E3K-R10K4 wiring for max pro UL325-2018 10K Resistor wiring to E3K Photocell OPENING Direction Photocell (Reflector) Set switch to “LIGHT ON” LIGHT ON DARK ON SENSITIVITY Sensitivity Adjustment: Installation Steps: If the photocell does not respond to an obstruction, lower the sensitivity by 1.
Page 33
EMX WEL-200 Wiring Guide FOR MAX PRO SERIES www.max.us.com RECEIVER WEL-200R OPENING CLOSING TRANSMITTER TRANSMITTER WEL-200T WEL-200T WIRE WEL-200R WEL-200R OPEN & CLOSE RELAYS INSERT BOTH JUMPERS TO MATRIX III IN 10K POSITION 10K SENSOR INPUTS BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR MOTOR...
Page 34
CONNECTING RECEIVER (WEL-200R) TO TRANSMITTER (WEL-200T) Connecting is a two step process. First, on the receiver, press and hold the channel assignment switch until the green status LED begins rapidly flashing, then release; this will clear any existing assignment for that particular channel. Hold down the connection switch on the transmitter.
Page 35
Photocell (Reflector) CLOSING Direction SENSITIVITY 1 2 3 4 1 2 3 4 4W 2W NC COM PULSE ENERGIZED OPEN ONLY P P P HOTO CLS OPEN/CLS 12VDC OUT OPEN ONLY CLS ONLY OPEN/CLS 12VDC OUT...
Page 36
Photocell (Thru-Beam) CLOSING Direction emx irb-mon Single Gate Operator PHOTO CLS NC 12VDC OUT IMPORTANT: MUST 12VDC OUT Single Operator Transmitter (TX) Receiver (RX) Sensitivity Adjustment: Installation Steps: 12VDC OUT PHOTO CLS NC DIP-switches: SENSITIVITY OFF. COM. NOTE: POWER INPUT COM NO POWER MUST...
Page 37
Photocell (Thru-Beam) CLOSING Direction emx irb-mon Dual Gate Operators PHOTO CLS NC 12VDC OUTPUT 12VDC OUT IMPORTANT: MUST Secondary Primary Operator Operator Transmitter (TX) Receiver (RX) Sensitivity Adjustment: Installation Steps: DIP-switches: receiver OFF. SENSITIVITY PHOTO CLS NOTE: COM. POWER INPUT transmitter MUST COM NO...
Page 38
LOAD LOAD OPENING OPEN CLOSING LIMITS LIMIT 2 OBD PORT D POR MUST LEARNED BLACK BOX ACK B LIMIT 1 MAXIMUM CONTROLS RESET MOTOR 2 CLOSING DSP ARM CONTROLLER LIMITS LIMIT 2 ON/OFF ON/O BATTERY BATTE ALARM MOTION CONTROL PROGRAMMING...
Page 39
BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR MOTOR BATTERY BATTERY INPUT INPUTS BACKUP MODE BATTERY LEAVE OPEN IN USE OPEN 1 TIME REPLACE Safety Device LEAVE BATTERY MOTOR BATTERY POWER / CLOSED TEST POSITION POWER SOLAR IN INPUTS CLOSE ERD SENSITIVITY TIMER SLIDER LIMIT...
Page 40
optional magnet limit sensors IMPORTANT: MUST OPEN and CLOSE Magnet limit sensors are sold separately. WILL NOT remain GRAY MUST c k e OPEN POSITION B r a IMPORTANT: MUST be MUST be installed on BOTTOM installed on BOTH OPEN and CLOSE LIMIT SENSOR Limit Sensor...
Page 41
optional magnet limit sensors IMPORTANT: MUST OPEN and CLOSE Magnet limit sensors are sold separately. WILL NOT remain GRAY MUST c k e OPEN POSITION B r a IMPORTANT: MUST be MUST be installed on BOTTOM installed on BOTH OPEN and CLOSE LIMIT SENSOR Limit Sensor...
Page 42
DO NOT SOLAR MODE BATTERY MATRIX III BATTERY VOLTAGE INPUT ERROR C o n MOTOR BATTERY BATTERY INPUT BACKUP MODE INPUTS BATTERY LEAVE OPEN t r o IN USE OPEN 1 TIME l B o REPLACE LEAVE flexible BATTERY MOTOR MOTOR BATTERY POWER /...
Page 44
MAX F18 PRO UL CLASS - III, IV ONLY CERTIFIED TO CAN/CSA STD C22.2 NO. 247 Residential/Commercial Brushless DC Slide Gate Operators Made in USA 4009963 Maximum Controls LLC. 10530 Lawson River Ave Fountain Valley, Ca 92708 Tel: (949) 699-0220...
Need help?
Do you have a question about the MATRIX III MAX 1500 PRO and is the answer not in the manual?
Questions and answers
how to program new remote
To program a new remote for the Maximum Controls MAX 1500 PRO using the WEL-200 system:
1. Install 2 AA Lithium batteries in the WEL-200T transmitter. The green LED will flash twice every two seconds.
2. Install a properly terminated edge (8.2k or 10k) to the transmitter.
3. On the WEL-200R receiver, press and hold the desired channel assignment switch until all four LEDs flash, indicating programming mode.
This pairs the transmitter (remote) with the receiver for gate control.
This answer is automatically generated