Page 3
FROMM 168230.01EN_Version03 Opgelet! Leest U in elk geval de gebruiksaanwijzing, vooraleer de machine wordt opgesteld, geïnstalleerd en in gebruik genomen wordt. Daardoor zorgt U voor Uw eigen veiligheid en vermijdt U schade aan Uw machine. Achtung! Lesen Sie unbedingt die Gebrauchsanweisung vor Aufstellung-Installation-Inbetriebnahme.
FROMM 168230.01EN_Version03 GENERAL • This manual has been created to describe all functional capabilities of the Indicator and assist you during its installation and set up. • FOR EVERYTHING IN THIS MANUAL IS VALID, IF APPLIED! • For safety reasons the entire instruction manual should be read before setting in operation the machine/installation, solving failures and executing maintenance.
The following conditions have always to be satisfied, unless otherwise indicated in other instructions in this manual. • This Weighting system has been delivered by FROMM Stretch Wrapping Division and may only be applied for weighting of pallets which meet the requirements as mentioned in the description of the machine.
Page 6
FROMM 168230.01EN_Version03 • The machines are designed and implemented conforming to the safety laws in force. Consequently, no intrinsic fire risks are envisaged when the machine is used normally • As such, the equipment provided against the possibility of fire outbreaks inside the company are sufficient for any problems caused by the material used for the process •...
FROMM 168230.01EN_Version03 WARNINGS • The mean weighed noise level of the machine is less than 80 dBa. It is possible that, depending on the applied film, during wrapping of the pallets incidentally a noise level with a maximum of 80 dBa will be measured.
FROMM 168230.01EN_Version03 MAIN FUNCTIONS The calibration is done only by the pushbuttons at the front side of the indicator. The calibration is protected by jumper J3 (write protect) at the top on the right side of the main PCB. To enable to calibration place this jumper at the pins.
FROMM 168230.01EN_Version03 SET-UP • To reach the set-up push and hold the DM button for 5 seconds. The display counts down from 5 till 0. • During count down push the TARE and PRINT button simultaneously. The display shows the software version followed by “SEt”, the first item of the main menu.
Page 10
FROMM 168230.01EN_Version03 DISPLAY AND BUTTON SET-UP (USEr) Use the arrow button to select this menu item, push the TARE button to enter it. The parameters are: 2.3a : SHUtoF (= shut off) automatic indicator shut off. (0 = always on; 1-99 = shut off time in minutes) 2.3b :...
FROMM 168230.01EN_Version03 EXAMPLE WEIGHT CALIBRATION For this example the next values are used: • 4 loadcells 1000 kg each, 3mV/V. • scale capacity 2000 kg. • readability multirange per 0,1 kg till 300 kg, per 0,2 kg from 300 till 1000 kg and above 1000 kg per 0,5 kg.
FROMM 168230.01EN_Version03 ERRORS Dashes at the upper part of the display indicate an overload of the scale of more than 9 counts. LobAt 1: battery voltage indicator is to low (under 7V) LobAt 2: battery voltage transmitter is to low (under 7V)
FROMM 168230.01EN_Version03 PRINTER OUTPUT PROTOCOL RS232 output : 1 startbit, 8 databits, 1 stopbit. Baudrate : selectable 1200 - 19200 in set-up item 2.4b (bAUd) DTR time-out : 2 seconds see error 07 This protocol only is valid if the automatic print function in 2.4d (AutoPr) is switched off. The information is send after pressing the PRINT button.
FROMM 168230.01EN_Version03 COMPUTER OUTPUT PROTOCOL RS232 output : 1 startbit, 8 databits, 1 stopbit. Baudrate : selectable 1200 - 19200 in set-up item 2.4b (bAUd) DTR time-out : 2 seconds see error 07 This protocol only is valid if the automatic print function in 2.4d (AutoPr) is switched on and is not working after pressing the PRINT button.
Need help?
Do you have a question about the FS 2 Series and is the answer not in the manual?
Questions and answers