Do you have a question about the BTM-303D and is the answer not in the manual?
Questions and answers
Summary of Contents for Biontech BTM-303D
Page 1
OPERATION MANUAL Model : BTM-303D * There is a protection film on the control panel of this product. * Please read each section thoroughly for proper unit usage. * Keep the manual in a safe place and refer to it whenever needed.
•Filter Replacement Period ........................ •Filter Replacement Procedure 8. Using the Cleaning Filter ........................9. Using Ionized Water..........................10. Support ..................................................... •Questions and Answers (Q&A) ........................... •About after service (A/S) 11. Product Specifications ..........................BTM-303D (영).indd 2 2016-08-31 오후 1:26:05...
Owner’s Manual For Mounted Wall For Water Outlet OPERATION MANUAL Model : BTM-303D * There is a protection film on the control panel of this product. (Optional Item) * Please read each section thoroughly for proper unit usage. * Keep the manual in a safe place and refer to it whenever needed.
Fuse Holder Fuse. Audio Speaker Voice and Melody. Audio Volume Control Loudness control. Water Supply Control Valve Ionizer operation and water flow adjustment(On/Off). Electric Cord Electric cord for connecting with the electric wall socket. BTM-303D (영).indd 4 2016-08-31 오후 1:26:07...
Page 5
-Selecting Acidic water: [ Acidic ] IMPORTANT: When seeing 3.5 on the display and the melody is playing please do Not drink the water until the melody stops playing or you select a different setting. BTM-303D (영).indd 5 2016-08-31 오후 1:26:07...
●Items related to the general behaviors of users. General Disconnecting the plug ●The plug needs to be disconnected from the wall socket if from the wall socket. there is a possibility of malfunctioning or lightening. BTM-303D (영).indd 6 2016-08-31 오후 1:26:08...
Page 7
● Should not arbitrarily modify, disassemble or repair the product. If not followed, fires and electric shocks can be caused. The company will not be held responsible for any accidents generated from such activities. BTM-303D (영).indd 7 2016-08-31 오후 1:26:08...
●The purification filter can be broken due to freezing if the product is used in a place where it is freezing cold, requiring the product, if not used, to be stored in a place where the breaking due to freezing can be prevented, but after the purification filter is removed first. BTM-303D (영).indd 8 2016-08-31 오후 1:26:08...
(Alkaline water flow standard: 1.5 ± 0.5 ℓ/min) Should use the standard inlet hose (1/4”) and fix the valve cover in the direction of the hose to prevent the hose from being bent or the fastening nut from being loosened. BTM-303D (영).indd 9 2016-08-31 오후 1:26:08...
Page 10
■Should use the standard inlet hose (1/4”) and fix the the adapter to the cold water pipe (Drawing 2.) valve cover in the direction of the hose to prevent the hose from being bent or fastening nut from being loosened. BTM-303D (영).indd 10 2016-08-31 오후 1:26:09...
Page 11
Cold water inlet Nut Cold water inlet Nut 4. Hose Connected Method After finishing of connection, cover the water supply valve cover part with screws again. valve cover Hose Hose Tap water Safety pin Diverter valve BTM-303D (영).indd 11 2016-08-31 오후 1:26:10...
Page 12
7. Audio volume control 1. Using Flat-head driver, adjust the loundness. 2. Screwing yellow nail to left, volume will be up. Screwing it to opposite, Volume will be down. BTM-303D (영).indd 12 2016-08-31 오후 1:26:10...
6. Never block the air openings of the product or place ot on a soft surface, such as a bed or couch, where the air openings may be blocked. keep the air openings free of lint, hair, and the like. BTM-303D (영).indd 13 2016-08-31 오후 1:26:10...
●Should turn off the water pipe when filing the calcium. - If not followed, water leakage can be caused. ●Check where the calcium container cap is surely fastened. - If not fastened surely, water leaksge can be caused when the water flows through. BTM-303D (영).indd 14 2016-08-31 오후 1:26:10...
● Do not block the water outlet. If blocked, water leakage or malfunctioning can be caused. ● Should place the outlet hose (Acidic water outlet) below the main case. ● Do not use the water which is above 30°C (86°F) If not followed, malfunctioning can be caused. BTM-303D (영).indd 15 2016-08-31 오후 1:26:10...
Use the product in a place where there is no slope. General activated carbon Water Outlet Non-woven fabric General activated carbon Calcium sulfite Classification Place of origin Remarks Special Fiber Pad UF Membrane Filter Korea BTM-303D (영).indd 16 2016-08-31 오후 1:26:10...
'Alkaline'. In order to stop the operation in the middle of the use, other selection buttons need to be pushed to select other functions. BTM-303D (영).indd 17 2016-08-31 오후 1:26:11...
- There can be ‘water dripping’ from the outlet pipe in the middle of the rinsing process, which is not an abnormal situation. - The operation will stop automatically when the indication light for the rinsing is turned off after the rinsing is finished. Voice guidance:“ Self Cleaning.” BTM-303D (영).indd 18 2016-08-31 오후 1:26:12...
● When there is rusty water due to aged pipes ● Lots of impurities in the water for a short period of time ● If the product is used in a place where the water pressure is low. BTM-303D (영).indd 19 2016-08-31 오후 1:26:12...
Follow the steps mentioned above even when replacing the filter earlier than the time for the replacement. The filter without our company logo is not a genuine product. When a genuine filter is not used, the quality cannot be guaranteed and the normal after sales service(A/S) will not be available. BTM-303D (영).indd 20 2016-08-31 오후 1:26:13...
Cleaning filter will eliminate most Calcium scale on the plates and inside the chamber of your ionizer allowing for longer life and better performance. Cleaning filter provides the way to keep your water ionizer. insures that the platinum/titanium plates remain clean and free of calcium. How to use cleansing filter (Optional purchase) urely BTM-303D (영).indd 21 2016-08-31 오후 1:26:13...
■Heavy drinking and hangover It will be good for your health if you drink it before going to bed or drink it on the empty stomach in the morning. BTM-303D (영).indd 22 2016-08-31 오후 1:26:13...
Page 23
■When deposits are formed at a kettle or a pot is incrusted due to burning When deposits are formed at the kettles, or pots are incrusted due to burning, try to place them in the acidic ionized water for overnight, and then they will be made clean. BTM-303D (영).indd 23 2016-08-31 오후 1:26:14...
3 minutes. What temperature the flowing water is allowed ● Only the water temperatures that is below to keep ? 30 C can be used within the water unit. BTM-303D (영).indd 24 2016-08-31 오후 1:26:14...
Page 25
● Use the water after setting the appropriate level of ionized water. Which water would you recommend for the ● It is recommended that the infants are fed infants? low alkaline ionized water. (Alkaline Ionized Water level 1.) BTM-303D (영).indd 25 2016-08-31 오후 1:26:14...
[Strong alkaline], [Acidic] and [Purified water] is used, Once after [Strong alkaline], [Acidic] and [Purified water] is used, the indication will change into [Alkaline the setting will be restored to the previously set value of [Alkaline] automatically. => Not malfunctioning. BTM-303D (영).indd 26 2016-08-31 오후 1:26:14...
Page 27
(Contact the sales shop or the main office when the problem is not solved even after the widest opening of the water branch pipe) ●Is the water flow volume too high? => Adjust by the water supply control valve. BTM-303D (영).indd 27 2016-08-31 오후 1:26:14...
Page 28
(The water may not taste good) => Set it right Water leaks from the bottom of the main body. ●Is the acidic water drainage hose bent or crushed? (The water may not taste good) => Set it right BTM-303D (영).indd 28 2016-08-31 오후 1:26:14...
Page 29
●Check whether the filter is appropriately fastened into the Water leakage at the water purifier. (Filter socket) filter socket. => After checking the filter packing, you need to fasten it to the filter base appropriately. BTM-303D (영).indd 29 2016-08-31 오후 1:26:14...
Page 31
Problem due to consumer not using a consumable Charged Charged service or optional item as designated service Any other problem as a result of external causes. Problem that occurred due to product serviced by an unauthorized person BTM-303D (영).indd 31 2016-08-31 오후 1:26:14...
Page 32
Property office (international standard for nvironmental management system) Administration Bion-Tech Co.,Ltd. Distributor Manufacturer Bion-tech Co., Ltd. 298-15 Gongdan-ro(Geumjeong-dong), Gunpo-si, Gyeonggi-do South Korea Tel : 82-31-459-3853 Fax 82-31-429-3859 E-mail : btm@biontech.biz http://www.bion-tech.com (Korean) http://www.biontech.biz (International) BTM-303D (영).indd 32 2016-08-31 오후 1:26:15...
Need help?
Do you have a question about the BTM-303D and is the answer not in the manual?
Questions and answers