Easytop concealed domestic water meter unit Instructions for Use for drinking water installation Model Year built: 2231.4 from 04/2017 en_INT...
Page 2
Easytop concealed domestic water meter unit 2 from 16...
Table of contents Table of contents About these instructions for use Target groups Labelling of notes About this translated version Product information Standards and regulations Intended use 2.2.1 Areas of use 2.2.2 Media Product description 2.3.1 Overview 2.3.2 Threaded connection 2.3.3 Markings on components 2.3.4...
This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.
2 Product information Standards and regulations The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your viega.com/standards . country at Regulations from section: Fields of application Scope / Notice...
Page 7
Product information Regulations from section: Product description Scope / Notice Regulations applicable in Ger- many Suitability for drinking water Trinkwasserverordnung (TrinkwV) installations Suitability for drinking water DIN 50930-6 installations Requirements in plastic compo- DVGW-Arbeitsblatt W270 nents in drinking water installa- tions Regulations from section: Threaded connection Scope / Notice...
DIN EN 806-5 drinking water installations Intended use Coordinate the use of the model for areas of use and media other than those described with the Viega Service Center. 2.2.1 Areas of use Use is possible in the following areas among others: Drinking water installations The model serves as a shut-off for the storey units.
2.3.4 Compatible components Water meter / Measuring capsule Observe the manufacturer's instructions for mounting and use. Should you have any questions on this subject, please contact the Viega Service Center. Easytop concealed domestic water meter unit 9 from 16...
Product information 2.3.5 Technical data Observe the following operating conditions for the installation of the model: Operating temperature [T 90 °C Operating pressure [P 1.0 MPa (10 bar) Information for use 2.4.1 Corrosion Overground pipelines and fittings in rooms do not normally require external corrosion protection.
Page 11
Product information Fig. 1: Model 2236.10, equipment set Fig. 2: Model 2236, equipment set Fig. 3: Model 2236.50, public building model Easytop concealed domestic water meter unit 11 from 16...
Page 12
Product information Fig. 4: Model 2235.90, mounting set front position Fig. 5: Model 2235.95, mounting set rear position Easytop concealed domestic water meter unit 12 from 16...
Handling 3 Handling Assembly information 3.1.1 Installation dimensions A - at least 45 mm B - maximum 77 mm 3.1.2 Mounting instructions Checking system components Do not remove the model from the packaging until immedi- ately before use. System components may, in some cases, become damaged through transportation and storage.
Handling Observe the following when mounting: flow direction indicator minimum / maximum installation depth use suitable tools Choose the place of installation so that the fitting is easily accessible and simple to operate. Assembly 3.2.1 Mounting the valve Carry out a functionality test after initial mounting. Installation is possible in masonry (wet construction) and in dry con- structions (pre-wall / duct installations).
Handling Attaching in dry constructions Attach the fitting from behind with the fixing set onto a Viega fitting holder with slot nuts. Seal the wall lead-in on the front side of the wall with the self-adhe- sive sealing flange. Fig. 6: 2235.95 Fixing set back Attach the protective sleeve of the valve in front of and behind the cladding (e.
Observe the applicable regulations for the operation and maintenance Ä „Regulations from section: Mainte- of drinking water installations, see nance“ on page 8 . Viega recommends actuating the fitting regularly and checking its function. Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.