Note to End User – Keep these instructions with your Owner’s Manual for future reference. FOR YOUR SAFETY While performing installations described in this booklet, gloves and either safety glasses or goggles should be worn. READ CAREFULLY. KEEP THESE INSTRUCTIONS. Secure Storage Solutions ELK2019...
Table of Contents Parts Supplied..............................3-5 Evidence Locker Installation Instructions......................6-7 End Panel Installation Instructions........................8 Leveling an Evidence Locker..........................9 Keyless Lift Latch Adjustment........................10-11 Adjusting or Replacing Door or Components....................12-14...
Installation Preparation Tools and Materials You Will Need Drill 3/16” Drill Bit 1/8” Drill Bit Clamps Drivers for Screws Dead Blow Hammer or Mallet 4’ Level Composite Door Frame Shims, if needed (not supplied by Tiffin Metal Products) Tin Snips Tape Measure 7/16”...
Page 4
Parts Supplied - Continued EEP PRIMER SHEET METAL SCREW *Artwork for illustration purposes only. Evidence Locker configurations and part quantities may vary based on your order.
Page 5
Parts Supplied - Continued Secure Storage Solutions *Artwork for illustration purposes only. Evidence Locker configurations and part quantities may vary based on your order.
Evidence Locker Installation Instructions STEP 5 STEP 1 After unpacking lockers, align left to right with Attaching trim with no end panels - multiple door side opening facing you as pictured To attach the trim to the frame, drill 3/16” holes under STEP 5 to the right.
Page 7
Evidence Locker Installation Instructions - Continued STEP 10 STEP 7 If applicable, field cut the trim to length as If either the front or rear of the locker will be needed using tin snips. proud of the wall, adjust the location of the recessed trim so that it will be flush with the wall and present a finished appearance.
End Panel Installation Instructions STEP 1 STEP 3 Ensure the frame is clean and dry to promote Remove the backing from the tape on the end good adhesion between the end panel and panel and press firmly into place ensuring that locker.
Leveling an Evidence Locker STEP 1 STEP 3 Look at the access holes on the hinge side of Place the thin tapered edge of the shim the locker to determine what type of screw was directly under the hinge side of the locker and used to attach it to the wall or the next locker.
Keyless Lift Latch Adjustment STEP 1 Make sure locker is plumb and level. See page 9 for instructions on leveling a locker. Check doors and locks after shimming to see if that was the issue. STEP 2 Ensure that the doors did not shift or sag during shipping by examining the gap between the door and frame.
Page 11
Keyless Lift Latch Adjustment - Continued STEP 7 Tighten down the bolts loosened in STEP 4 and check the function of the locks. STEP 8 Repeat STEPS 4-6 if more adjustment is needed. STEP 9 Test several times to ensure that the lock is working consistently.
Adjusting or Replacing Door or Components STEP 1 Drill a hole in the plastic covers on the inside of the door big enough so that the tip of a flat blade screwdriver will fit. STEP 2 Put the tip of the screw driver in the hole and pry the plastic cover off exposing the PEMs and nuts underneath.
Page 13
Adjusting or Replacing Door or Components - Continued STEP 5 STEP 7 Remove the 3/8” locknuts holding the hinge cap When replacing the door make sure that the on. Remove the hinge cap and any washers that thin black spacer is on the top of the door. It will may be on the PEM studs.
Page 14