OWT Industries Black Max BM10700 Manual

Advertisement

Available languages

Available languages

major generator features

 Honda GX390 engine
 Electric Start
 Cast-iron cylinder sleeve
 Low lubricant alert system
 Receptacles on control panel
 Cord Retainers
 Automatic voltage regulator (AVR)
 8 gallon metal fuel tank
 Analog Hour Meter
 Portability Kit

control panel

a. 120 V, 20 ampere Duplex receptacle
20 amps of current may be drawn from each half of the recep-
tacle. However, total power drawn must be kept within nameplate rat-
ings. These receptacles may be used along with the twistlock recep-
tacle provided the generator is not overloaded.
B. 120/240 V, 30 ampere twistlock receptacle
A maximum of 30 amps may be drawn from the 120/240 volt
receptacle, provided it is the only receptacle used. However, current
must be limited to the nameplate rating. If the 120/240 volt receptacle
is used along with the 120 volt receptacle, the total load drawn must
not exceed the nameplate ratings.
c. circuit Breakers
The receptacles are protected by an AC circuit breaker. If the
generator is overloaded or an external short circuit occurs, the circuit
breaker will trip. If this occurs, disconnect all electrical loads and try
to determine the cause of the problem before attempting to use the
generator again. If overloading causes the circuit breaker to trip, re-
duce the load. NOTE: Continuous tripping of the circuit breaker
may cause damage to generator or equipment. The circuit breaker
may be reset by pushing the button of the breaker.
D. engine on/off switch
e. cord retainer
The cord retainer is used to prevent plugs from being pulled out
of the 120-volt receptacles.
f. analog Hour meter
g. low oil shut Down circuit protector
f
a
D
ON
OFF
START
120V AC/CA
ENGINE SW.
ON
OFF
Cord
CIRCUIT PROTECTOR
Retainer
g
e
BM10700/BM10711
R
This sheet updates battery installation and removal
instructions on page 7.
B
120V/240 AC/CA
120V AC/CA
NEUTRAL FLOATING
NEUTRAL FLOTAS
Cord
Retainer
c
7
OWT Industries, Inc.
P.O. Box 35, Hwy. 8, Pickens, SC 29671, USA
1-800-726-5760
electrIc start
This generator model is provided with both electric start and re-
coil start capabilities. Avoid prolonged cranking, as it can damage the
engine.
The battery provided is a nominal 12 volt sealed rechargeable
lead-acid battery and can be operated in any position without leak-
age. It complies with non-spillable battery regulations. Its convenient
size offers a 30% reduction over conventional batteries.
Length = 7.14 inches, Width = 3.03 inches,
Height = 6.59 inches, Weight = 12.56 lbs
18AH Rating
UL Recognized
Battery Kit Parts List
Item Description
Qty
A
*Bolt, M5 x M12 ............... 2
B.
*Nut, 5 mm ....................... 2
C.
*Flat Washer, M5 ............. 2
* These are standard parts available at your local hardware store.
Note: Brand New Generators are shipped with the Battery Con-
nections disconnected. The Positive and Negative Terminals
must be connected to the Battery before the Electric Start Fea-
ture will work.
Initial Battery Connection - Refer to Installation Instructions Below.
Battery Installation & Removal:
Installation: Hook up the new battery, or re-install the new bat-
tery, as follows: Remove the nuts and bolts from the battery bracket;
remove bracket and set aside. Connect the red wire to the positive (+)
terminal and the black wire to the negative (-) terminal with the bolt,
nut, and washer provided. Make sure all connections are tight. Place
the battery in the position provided. Replace the battery bracket.
Install bolts and nuts; tighten securely. Your battery is now connected
and ready for use.
Removal: Remove the nuts and bolts from the battery bracket;
remove bracket and set aside. Remove the nut and bolt from the neg-
ative and positive post, being careful not to short across the terminals.
(Shorting the terminals together can cause sparks, damage to the
battery or generator or even burns or explosions.) Always abide by
the safety warnings provided with the battery. Remove the battery
and dispose of according to local and state regulations.

WarnIng:

To reduce the risk of electrocution or explosion, do not short
circuit the battery terminals or charge in a sealed container. Keep
sparks and flame away.
BLACK WIRE ( – )
BATTERy
BRACKET
POSITIVE ( + )
NEGATIVE ( – )
TERMINAL
TERMINAL
RED WIRE ( + )
BOLT
NuT
987000-597
2-2-09 (REV:01)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Black Max BM10700 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for OWT Industries Black Max BM10700

  • Page 1: Control Panel

    120V AC/CA NEUTRAL FLOATING ENGINE SW. NEUTRAL FLOTAS Cord Cord CIRCUIT PROTECTOR Retainer Retainer POSITIVE ( + ) NEGATIVE ( – ) TERMINAL TERMINAL OWT Industries, Inc. P.O. Box 35, Hwy. 8, Pickens, SC 29671, USA 987000-597 1-800-726-5760 2-2-09 (REV:01)
  • Page 2 120V AC/CA 120V AC/CA ENGINE SW. NEUTRAL FLOATING NEUTRAL FLOTAS Cord Cord CIRCUIT PROTECTOR Retainer Retainer terMINal terMINal tuerca posItIVa ( + ) NeGatIVa ( – ) OWT Industries, Inc. P.O. Box 35, Hwy. 8, Pickens, SC 29671, USA 1-800-726-5760...

This manual is also suitable for:

Black max bm10711

Table of Contents