ARC Euro Adapter -CV
The ARC Euro Adapter allows you to use Kemppi's WeldEye welding
management software for monitoring any welding machine equipped with
a Euro connector. For more information about Kemppi's welding quality
management solutions, please visit www.weldeye.com.
1.
Three wire liners are included in the package. Select one of them according
to the filler wire size you are using, and install the liner into the adapter.
2.
Connect the ARC Euro Adapter to the Euro connector on the wire feeder.
Push the connector and turn clockwise until it's firmly seated.
3.
Connect the welding gun to the ARC Euro Adapter. Push the connector and
turn clockwise until it's firmly seated.
4.
Attach the ARC Control Cable to the adapter and turn clockwise until it is
firmly seated.
7.
4.
(Turn the page for a full setup overview.)
8.
1.
L1
1.
L2
1.
L3
5.
Connect the ARC Control Cable to the Adapter Power Source.
6.
Connect the Smart Reader or the Digital Connectivity Module (DCM) to the
ARC Control Cable.
7.
Connect the branch connector to the welding equipment and connect
the voltage sensing cable between the branch connector and the Adapter
Power Source.
8.
Install the plug and plug in the Adapter Power Source to a 220 – 415 V wall
socket. Alternatively the Adapter Power Source can be connected to the
mains connector inside the power source.
9.
Test that the system works.
The plug installation and all installations inside Kemppi welding machines may be carried
out only by an authorized electrician.
The maximum allowed welding current is 500 A.
The 'CV' stands for the qualities being measured (Current and Voltage).