Findeva FKL 200 Installation And Short-Form Operating Manual

Advertisement

Quick Links

www.netter-findeva.com
---------------------------------------------------
Installation and Short-Form Operating Manual for FKL 100/150/200 si
The pneumatic knockers (FKL) comply with the EC Machinery Directive 98/37/EC. They also comply, in
particular, with Standard EN 292, Parts 1 and 2.

Important Information

FINDEVA AG is unable to accept responsibility whatsoever for damage to property or injury if technical
modifications are made to the product or if the information and instructions in this Operating Manual are not
followed.
Pneumatic vibrators must be installed and operated by an experienced person.
Risk of injury!
Compressed-air units, such a vibrators, filters, oilers and the air hoses, may be very highly
pressurised. The system must be disconnected from the compressed air supply before such
units are installed or serviced. The units must be depressurised.
Air pressure may produce extremely loud noise. Consequently, all persons in the surrounding
area of the pneumatic vibrator must wear ear defenders.
Comply with national and local regulations and regulations governing installation and use of
pneumatic systems.

Noise level

The noise level of a non-shielded knocker fitted on a metal panel exceeds 85 dB(A), if only the
single noise event is considered. The sustained level is below this, depending on impact
sequence. The noise emitted by the device may be attenuated by sheathings or coverings.
Noise defenders must be worn in the noise area.

Attachment of the knocker

Vibrators or knockers and parts of the structure may become detached as the result of
vibration. Screw and nut locking devices must be used.

Lubrication

The FKL 100 pneumatic knocker can be operated with dry compressed air and, thus, unlubricated. If
compressed air containing oil is selected for operation of the knocker, such air must be also be used always
since the basic lubrication of the knocker is flushed out as the result of the air containing oil. The basic version
of the knocker can be operated in a temperature range from –20°C to 80°C. A special version is available for
temperatures between –40°C and 130°C.

Air filter and pressure controller

All compressors feature air filters. However, use an air filter with a particle permeability rating of 5 um. This will
help to prolong the knocker's service life.
FKL Operating Manual
09.08.2002
findeva AG
Findeva AG
Loostrasse 2
CH – 8461 Oerlingen

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FKL 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Findeva FKL 200

  • Page 1 Standard EN 292, Parts 1 and 2. Important Information FINDEVA AG is unable to accept responsibility whatsoever for damage to property or injury if technical modifications are made to the product or if the information and instructions in this Operating Manual are not followed.
  • Page 2 AG --------------------------------------------------- Compressed air lines Of course, it is possible to control vibrators by varying the air pressure or air volume. However, please ensure that the compressed-air units are correctly dimensioned. Quick-release catches are used for connection to the knocker and to the pneumatic control system.
  • Page 3 AG --------------------------------------------------- Operating conditions Intermittent knockers can be used in dusty environments. The piston seals are suitable for oil-free operation. Standard installation for Series FKL 1. The control system is the responsibility of the customer In this case, intermittent control or (ON / OFF) is implemented by the customer by means of a 3/2-way normally open air valve.
  • Page 4 FKL 100 can be used for wall thicknesses up to 5 mm FKL 150 can be used for wall thicknesses up to 8 mm FKL 200 can be used for wall thicknesses up to 12 mm FKL Operating Manual 09.08.2002...
  • Page 5 AG --------------------------------------------------- Dimensions (mm) mechanical mechanical force control force control 4 x E1 KNO C KE R F KL-100 Ø 13 F KL-150 Ø 140 Ø 115 Ø 13.5 385 F KL-200 Ø 180 Ø 152 Ø 17 FKL Operating Manual 09.08.2002...

This manual is also suitable for:

Fkl 100Fkl 150

Table of Contents