APPLICATION
The humidity control provides automatic low voltage
control of humidifiers in central heating and cooling
equipment for both humidification and dehumidification
applications. See Fig. 1. It has an spst, snap-acting,
dust-proof switch that opens when humidity rises above
the control setting. It is designed for wall or surface duct
mounting.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a haz-
ardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable
for your application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
CAUTION
Personal Injury Hazard.
Power supply can cause electrical shock.
Disconnect power supply before beginning
installation.
Location and Mounting
A mounting template is included for mounting the
humidity control next to your thermostat. See Fig. 2.
However, the humidity control can be mounted in any
other convenient location in the living area or equipment
room.
NOTE: The humidity control electrical connections are
not shared with the thermostat.
® U.S. Registered Trademark
Copyright © 2003 • All Rights Reserved
ASYSTAT625A
Humidity Control
HOLE FOR WIRING
THE DUCT MOUNTING
INSTALLATIONS
Fig. 1. Humidity control.
Wall Mounting
IMPORTANT
Mount the control in an area with average
room temperature and average relative
humidity.
Select a location for mounting the humidity control:
1. Hold the mounting template (included) next to
your thermostat. Select the mounting side for the
humidity control. The template is reversible for
mounting on either the left or right side of the
humidity control. See Fig. 2.
2. Mark the holes for the two mounting screws
(included). Then mark the hole for the low voltage
wiring on the template that corresponds with the
side selected in step 1.
3. Remove the template and drill the holes.
4. Run low voltage wiring to the location and pull
about 6 in. (152 mm) of wire through the hole.
5. Plug hole with nonflammable insulation to prevent
drafts from affecting the control operation.
6. Remove the humidity control case from the base.
See Fig. 1.
7. Position the base on the wall with the arrow up.
8. Use the two in. (25 mm) mounting screws to
secure the base to the wall.
INSTALLER'S GUIDE
CASE REMOVAL
SLOT
M19844
Pub. No.: 12-5034-01
69-1699

Advertisement

loading

Summary of Contents for American Standard ASYSTAT625A

  • Page 1 ASYSTAT625A Humidity Control INSTALLER’S GUIDE APPLICATION The humidity control provides automatic low voltage control of humidifiers in central heating and cooling equipment for both humidification and dehumidification applications. See Fig. 1. It has an spst, snap-acting, dust-proof switch that opens when humidity rises above the control setting.
  • Page 2: Duct Mounting

    ASYSTAT625A HUMIDITY CONTROL MOUNTING ALTERNATE LOCATION THERMOSTAT TEMPLATE WALLPLATE RETURN RETURN 6 in. (152 mm) 15 in. (381 mm) MINIMUM MINIMUM MOUNTING HOLES (2) WIRING HOLES FOR MOUNTING ON RIGHT. BEST M19830 USE LEFT HOLES FOR MOUNTING ON LEFT. LOCATION Fig.
  • Page 3 ASYSTAT625A HUMIDITY CONTROL HEATING CYCLE HUMIDITY CONTROL WIRING HUMIDISTAT WATER SOLENOID LEAD WIRE CAUTION TRANSFORMER Personal Injury Hazard. Power supply can cause electrical shock and (HOT) injury. Disconnect power supply before installation or CURRENT SENSING servicing. RELAY HUMIDIFIER All wiring must comply with applicable local codes, ordi- POWER SUPPLY.
  • Page 4: Humidity Control Adjustment

    ASYSTAT625A HUMIDITY CONTROL HEATING CYCLE HUMIDITY Setpoint Adjustment CONTROL ADJUSTMENTS Set the humidity setpoint according to the prevailing outdoor temperature. See Table 1 for recommended settings. Humidity Control Adjustment To maintain optimum humidity control without causing Table 1. Recommended Humidity Control Setting.
  • Page 5 ASYSTAT625A HUMIDITY CONTROL COOLING CYCLE HUMIDITY CONTROL WIRING HEAT PUMP VARIABLE SPEED O.D. SECTION THERMOSTAT AIR HANDLER (SINGLE SPEED) See Fig. 10 and 11 for air handler and furnace wiring for cooling cycle humidity control. CAUTION HUMIDISTAT Personal Injury Hazard.
  • Page 6: Operation And Checkout

    ASYSTAT625A HUMIDITY CONTROL FIELD WIRING DIAGRAM FOR VARIABLE SPEED 2 STAGE FURNACE 2 STAGE HEATING, 1 STAGE COOLING USING A 1 STAGE HEATING, 1 STAGE COOLING THERMOSTAT (OUTDOOR SECTION WITHOUT TRANSFORMER) FURNACE GROUND VARIABLE SPEED JUNCTION THERMOSTAT SCREW 2-STAGE FURNACE TO 115 V 1 PH.,...
  • Page 7 ASYSTAT625A HUMIDITY CONTROL Pub.No.:12-5034-01 69-1699...
  • Page 8 ASYSTAT625A HUMIDITY CONTROL American Standard Inc. 6200 Troup Highway Tyler, TX 75711-9010 Pub.No.: 12-5034-01 69-1699 G.H. 11-03 For more information, contact your local Dealer (Distributor).