PECIFICATIONS
Input Voltage: 12-24 Volt DC or 12 Volt AC
Power Consumption: 120mA max @ 24 VDC, 20mA idle
3A Power Supply is recommended for use with
NOTE:
door strike or magnetic lock
Programmable Relay:
rated at 2A @ 30VDC (inductive load)
Operating Temperature:
o
o
o
-40
C to 125
C (-40
F to 257
Available Models with Inst alled Dim ensions:
7510:
Single-Gang Style Keypad
3.20" W X 5.10" H x 0.75" D
7520:
Mullion Surface-Mount Keypad
1.75" W X 7.125" H x 1.00" D
7530:
Mullion Mortise-Mount Keypad
1.75" W X 7.125" H x 0.25" D
User Codes: Up to 200 unique codes including
1 master code. Codes will be between 4 and 8
digi ts in length. Codes are st ored in nonvolat ile
EEPROM memory.
Lockout Feature: Keypad will lock out all
funct ions for 30 seconds after three consecutiv e
invalid codes.
Factor y Default Sett ings:
Master code 1 2 3 4
User code
5 6 7 8 9 0
Relay Time 5 seconds (Momentary)
P
D
HYSICAL
ESCRIPTIONS
LED Explanation:
Green LED:
Steady off = D oor rel ay deactiva ted
Steady on = Doo r rela y acti vated
Red LED:
Normal Operation:
i)
Three sec onds on = Inv alid code
entered.
ii)
Slow flash = 30 second delay due to
three consecutive invalid codes entered.
Progr amm ing Mode:
i)
Slow flash = Program standby, ready to
accept new function.
ii)
Fast flash = Program in progress,
awaiting input.
iii) Very fast flash = Erasing all user codes.
Form C, dry contacts
o
F)
P
S
LATINUM
I
NSTALLATION AND
A
M
VAILABLE
ODELS
Model 7510
(Front)
Model 7520
Model 7530
(Front)
(Side)
7500 K
ERIES
P
ROGRAMMING
P
ROGRAMMING
Enter Programming Mode ** (master code) **
Example:
** 1234 **
Programming Functions:
Set Relay to M omentary
1 (time in seconds) #
Example:
1 05 # (Sets to 5 secs)
Set Relay to Latch
1 00 #
Add New User
2 (user n umber) # (user
code) # (user code) #
Example:
2 002 # 22222 # 22222 #
Change Existing User
2 (user n umber) # (user
code) # (user code) #
Example:
2 002 # 23456 # 23456 #
Change Master Code
2 0 # (new master code) #
(new master code) #
Example:
2 0 # 382436 # 382436 #
Erase a User Code
3 (user code) #
Example:
3 23456 #
Erase All Users
4 (master code) #
Example:
4 382436 #
Note: New Master Code must be between 4 & 8 digits.
Option 4 erases all User Codes, but not the
Master C ode.
Wire Connections:
Power - Connect either a 12 - 24 volt direct
current (DC) or a 12 volt al ternating current (AC)
power supply to these terminals. Polarity does not
matter, as the keypad has been designed to work in
both directions. Power supplies outside this range
may cause permanent damage to the keypad.
Common - This terminal is the Common output
of the relay and is used in conjunction with the
N.O. or N.C. Terminals (see below) to control a
door lock.
N.O. - This term inal is the Norm ally Open
outpu t of t he relay . In a n orm al locked st ate,
this terminal is disconnected from the Common
terminal. In an unlocked state, this terminal is
connected to the Common terminal.
N.C. - This term inal is the Norm ally Closed
outpu t of t he relay . In a n orm al locked st ate,
this terminal is connected to the Common
terminal. In an unlocked state, this terminal
disconnects from the Common terminal.
Reset Button - This button is used to reset the
master code back to its factory default. Follow
the instructio ns out lined in the Programming
section, under Factory Reset Function.
EYPAD
I
NSTRUCTIONS
Q
G
UICK
UIDE

Advertisement

loading
Need help?

Need help?

Do you have a question about the PLATINUM 7500 SERIES and is the answer not in the manual?

Questions and answers

Summary of Contents for Corby PLATINUM 7500 SERIES

  • Page 1 7500 K LATINUM ERIES EYPAD NSTALLATION AND ROGRAMMING NSTRUCTIONS PECIFICATIONS ROGRAMMING UICK UIDE %¸ Input Voltage: 12-24 Volt DC or 12 Volt AC Enter Programming Mode ** (master code) ** %¸ Power Consumption: 120mA max @ 24 VDC, 20mA idle Example: ** 1234 ** 3A Power Supply is recommended for use with...
  • Page 2 ROGRAMMING THE EYPAD ENCH ESTING THE EYPAD All programming is performed using the Keypad. Here are This bench test assumes the keypad is unprogrammed. If it some tips to help you program your keypad: has been progr amm ed, follow the Factory Reset Function found in the Programming section.) %¸...
  • Page 3 slow. Enter 1234 #. The Red LED will light steady for 3 seconds LED will light for three seconds (to acknowledge the entry) and and then continue to flash slow while a continuous tone will be then it will resume flashing fast. Re-enter your new master code heard.
  • Page 4 Application Examples N THE HTTP CORBY : 1501 E. P 18109-1588 DDRESS ENNSYLVANIA TREET LLENTOWN ENNSYLVANIA (800) OK-CORBY (610) 433-1412 ELEPHONE (610) 435-1963 ACSIMILE : (610) 433-0910 AXBACK...

This manual is also suitable for:

Platinum 7520Platinum 7530Platinum 7510