Drum Non-Rotating Malfunction Maintenance - Midea C01 Service Manual

Table of Contents

Advertisement

5 TROUBLESHOOTING

7. Drum non-rotating malfunction maintenance

Drum non-rotating
Y
Whether the door is
closed correctly
Y
Whether the door
lock is well
Y
Whether the inlet is
correct
Y
Whether the inner
wire connection is
correct
Y
Shut down the power,
open the door and
Rotate the drum .
check the drum rotate
flexibly or not.
Y
Whether the motor
is well
Y
Detach strap,
whether the drum is
rotating flexibly
Y
Change the control panel
N
Close the door
N
Change the door lock
N
Waiting inlet or inspect
overtime water inlet
malfunction
N
Replace it
N
Replace it
N
Reliable connection
N
Replace it
N
The drum is blocked
26