UNIT ONE
UNIT TWO
Product Manual
TP550 220x90 TP552 Ø160 TP554 Ø150 TP 556 Ø180
TP551 220x90 TP553 Ø160 TP555 Ø150
EN
TP557 Ø180
Trimbox NO2 Filter
®
ventilation systems

Advertisement

Table of Contents
loading

Summary of Contents for Titon TP551

  • Page 1 UNIT ONE TP550 220x90 TP552 Ø160 TP554 Ø150 TP 556 Ø180 UNIT TWO TP551 220x90 TP553 Ø160 TP555 Ø150 TP557 Ø180 Trimbox NO2 Filter ® Product Manual ventilation systems...
  • Page 2: Important Information

    2. Installation and maintenance personnel must wear suitable safety clothing to mini- mise the accident risk. 3. This manual covers the installation and maintenance of the Titon® Trimbox NO Filter® system. 4. The unit must be stored in a clean and dry environment. Do not install the appliance in areas where the following may be present or occur;...
  • Page 3: Titon® Recommend

    Titon® Recommend Any flexible ducting used must be pulled taught; Ducting must be installed in such a way that resistance to airflow is minimised; Duct joints to the unit’s duct ports must be fixed using a method that ensures a long term seal is achieved.
  • Page 4: Table Of Contents

    Titon®...
  • Page 5: Product Overview

    The units are fully foam insulated. This reduces duct bound noise and thermal transmission and helps to avoid condensation build up. Where the unit is installed in very cold spaces or if the outside air is below -5°C then a custom designed removable insulation jacket is available from Titon® see Accessories and Spare Parts List. Component Identification...
  • Page 6: Dimensions

    Dimensions 3 5 0 Service Void Unit Dimensions (excluding ports) Port Size(s) Rectangular Ports: 220mm x 90mm Round Ports: Ø150mm, Ø160mm and Ø180mm...
  • Page 7: Installation

    Installation Trimbox NO2 Filter® Read and observe the guidance & safety notices listed in Warnings, Safety information and Guidance . ƒ The Trimbox Filter is designed to be mounted in any orientation. ® The mounting surface substrate must be sufficiently strong to support the unit. ƒ...
  • Page 8: Wall Mounting (Vertical Only) Ducting Behind Unit

    Wall Mounting (Vertical Only) Ducting Behind Unit Attach the mounting brackets to the unit using M8 fixings provided. Mark positions of mounting holes onto wall using dimensions as shown. Prepare the wall in the positions specified for eight Ø6mm fixings at the marked positions. Fixings must be suitable for the mounting surface substrate and the weight of the unit.
  • Page 9: Ducting Connection

    Ducting Connection Airflow Direction The Trimbox Filter can be supplied with or without a prefilter installed.The air to be filtered must pass though a prefilter ® before the active carbon filters, therefore if the Trimbox Filter is supplied without a prefilter it is very important that it is ®...
  • Page 10: Maintenance                                             10

    Carbon Life Prediction Service If requested Titon® can provide a Carbon Life Prediction Service. Part used filters can be sent to Titon® whereby they are tested to determine the life expectancy of the carbon cells in use. If the filters are likely to have been exposed to hazardous...
  • Page 11: How To Change Filters                                          11

    DO 5463 Iss 01 The Active Carbon Filters are Dangerous for the Environment. Titon® do not offer a waste disposal service and therefore cannot accept filters for disposal, but can recommend the following company: Environmental Resource Group Tel: 0844 692 0000 Web: www.environmentalresourcegroup.com...
  • Page 12: Accessories And Spare Parts List

    Accessories and Spare Parts List Removable Insulation Jacket Titon® can provided a custom designed removable insulation jacket for the Trimbox NO2 Filter® which will provide 30mm of insulation material with thermal conductivity of 0.04W/(m.K). This jacket needs to be wrapped around the unit before mounting to a wall or ceiling.
  • Page 13: Fitting Kit                                                13

    Ducting Behind Unit Mounting Kit All Models TP558  NO2 Testing Kit A NO2 testing kit is available from Titon® that can be used to determine the levels of NO2 within the property. NO2 Testing Kit Exposure Time TP559 8 to 72 Hours...
  • Page 14: Service Record

    Service Record Serviced By Company Date Notes...
  • Page 15 Serviced By Company Date Notes...
  • Page 16 Information Pack and used as a service record. Installed by: MARKETING DIVISION 894 The Crescent, Colchester Business Park, Colchester, Essex, CO4 9YQ United Kingdom. Tel: +44 (0) 1206 713800 Fax: +44 (0) 1206 543126 Email: ventsales@titon.co.uk Web: www.titon.com ©2017 TITON® DO 5446 Iss 04...