Deta-Elis DeVita Professional Instruction Manual

Device for measuring the level of the body's condition with the possibility of increasing individual body protection by correcting the natural electromagnetic radiation of natural biosystems

Advertisement

Quick Links

Note the meaning of below terms used in the manual:
THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DeVita Professional and is the answer not in the manual?

Questions and answers

katerina
February 3, 2025

why the low power led indicator is on on the professional device ?what should i do?

1 comments:
Mr. Anderson
February 10, 2025

The "LOW POWER" LED indicator on the Deta-Elis DeVita Professional device turns on when there is a reduced voltage power supply. To resolve this issue, ensure that the AC adapter is properly connected to both the device and a functioning 220V wall socket. If the problem persists, check the power cord for damage and replace it if necessary. If the issue remains unresolved, contact a service center for further assistance.

This answer is automatically generated

Summary of Contents for Deta-Elis DeVita Professional

  • Page 1 Note the meaning of below terms used in the manual: THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS...
  • Page 2 Note the meaning of below terms used in the manual: THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS...
  • Page 3: Table Of Contents

    CONTENT 6.7. CONTRAINDICATIONS TO USING VRT MEASURES ....................6.8. QUADRANT TESTING ................................. 1. INTRODUCTION ......................................Setting up for quadrant testing ............................2. SPECIFICATION ......................................Conducting quadrant testing ..............................The measure mode ..................................Interpreting the quadrant testing results ........................Electroacupuncture effect mode ............................7.
  • Page 4: Introduction

    Electronic selector (ES) Device DeVita Professional is a unique development in the field of good health support without The Electronic Selector has many digitized remedies – the specifications are: medication.
  • Page 5 High frequency electrical equipment should not be close by, not computers and radio on the body. On the right side of the device are sockets to connect the individual modules equipment. Humidity and moisture can adversely affect the DEVITA PROFESSIONAL, so this must together (Fig. 2).
  • Page 6 6. MEASURE MODE – BASIC PRINCIPLES The DeVita Professional device allows for measure according to the methods developed by Dr. Voll and Dr. Schimmel. The «MEASURE» panel to control the measure mode is shown in Fig. 4. There are three indicator LED lights on the leſt...
  • Page 7: Electronic Selector (Es)

    The procedure is summarized in Diagram 2 below: 1. On the «THERAPY» panel, set the «THERAPY/DIAGNOSTICS» key to the «DIAGNOSTICS» position (see Fig. 6). 2. On the «MEASURES» panel, press the «PROBE» button (see Fig. 4, number 4). In this case, the «PROB»...
  • Page 8 until the «VEGATEST» LED on the device illuminates. You will now be in the VRT testing mode, VRT testing using the resonator (honeycomb) and the indicator will automatically jump from the 20 in Voll Mode to 80 in the VRT mode. This is with ampoules summarized in Diagram 3.
  • Page 9: Power

    DeVita Professional. It enables the practitioner to access any of these In order to begin to administer this remedy to the visitor, the «OUT» button must be pressed.
  • Page 10: Measure

    6.3 SETTING UP FOR BIORESONANCE MEASURES We use the mid-point of the fingers – not the acupoints as did Voll and Schimmel. We use a pressure of about 100 – 150 grams. Before you begin bioresonance testing, you need to set up the Professional device as follows: The pressure will differ according to age, the condition of the skin, whether they have psoriasis, Connect a short length of wire on the side of the device from the SEL connector to the PASSIVE etc.
  • Page 11 The electrode we use on the Professional is usually 3 mm. Moving to the «measurement plateau» takes place smoothly over 2-3 seconds, without jerking of the «active» electrode probe which could result in damage to the epidermis of the skin in the area of the BAP projection.
  • Page 12: Contraindications To Using Vrt Measures

    Practically, we first find the point during VRT at 80 and stabilize this – put in the code for For example, we may place these two: prostatitis and press OUT then retest the point – tap 3 times – on the first reading it will be about 80, then on the second and third there will be a sharp drop.
  • Page 13: Quadrant Testing

    Contraindications to the use of VRT Measure therefore include: QUADRANT TESTING Set MODE switch to «DIAGNOSTICS» • benign and malignant tumours Measurements are performed in the following sequence: • hereditary hemorrhagic anaemia 1. LH-RH • bleeding disorders 2. LF-RF • purpurae and other hemorrhagic conditions; 3.
  • Page 14: Interpreting The Quadrant Testing Results

    Interpreting the quadrant testing results QUADRANT MEASUREMENT RESULTS The indicator measurements are significant in identifying whether there is inflammation or AN EXAMPLE OF INFLAMMATION AN EXAMPLE OF INFLAMMATION degeneration in organs found in the 4 quadrants. The 4 quadrants relate to organs or physiological systems, as shown in the Diagram 9 below.
  • Page 15: Bioresonance (Brt) Effect Mode

    QUADRANT MEASUREMENT RESULTS One can examine the various organs in the lower quadrants using VRT testing using the following algorithms: PRELIMINARY CONDITION AN EXAMPLE OF INFLAMMATION FEMALE Ovaries – 4047*6 Vagina – 3026*1 Uterus – 4048*1 Cervix – 785*1 Endometrium – 792*1 Degenerative process h-f (r) h-f (l)
  • Page 16: Basic Bioresonance Effect (Brt)

    BIORESONANCE VRT TESTING The pathological signals in the body are consequently reduced and finally extinguished, and the physiological endogenous regulatory forces can regulate the biological processes unhindered. This form of effect is especially effective in cases where successful impact is impossible with Input Output traditional methods, or involves a lot of time or expense.
  • Page 17: Using Brt Against Allergies

    Using BRT against allergies For example, based on the VRT measurements made above, we will first treat LH (80) – RH (50) – as the LH has the highest reading, we place the hand electrode from the INPUT BRT into the A powerful feature of the Professional is the ability to invert pathological frequencies related to leſt...
  • Page 18: Wellness With Brt, Autonosodes And Es

    Wellness with BRT, autonosodes and ES 1. Connect the honeycomb or resonator and hand electrode with the INPUT BRT connector - body fluids 2. Connect resonator and hand electrode to OUTPUT BRT connector - water/alcohol It is also possible to take body fluids such as saliva, mucus, urine, faeces, nails and skin which all carry pathological frequencies and invert these to help neutralize them and therefore alleviate INPUT CUT: Body fluids symptoms –...
  • Page 19: Setting Filters In Brt

    Setting filters in BRT Checking that BRT is working Generally, it is best not to use the filters during BRT effect. The function of the filters is to cut In order to verify if the bioresonance effect module is working OK, the Wellness module control panel is needed.
  • Page 20: Electromagnetic Effect Mode

    Probe – there is also a small probe provided for this type of work in the Professional. There are two ways of setting up the DeVita Professional for Electromagnetic effect – one is in AUTO MODE where the device will set itself to wobble between 0. 1 – 99,99 Hz and back again In Electroacupuncture effect we have to connect both, the positive and the negative electrode.
  • Page 21: Manual Mode (Without Swing)

    Manual mode (without swing) Light flows through our eyes and triggers hormone production, which influences our entire complex biochemical system. This biochemical system then affects our being. And light does not Here we can set a fixed frequency but with no wobble. The following steps will set this up: travel alone.
  • Page 22: Complex Effect Mode

    To set up the Quantum Light mode, place switches on THERAPY, MANUAL mode, place RANGE 7.5 COMPLEX EFFECT MODE and SPEED to the MIN settings, INTENSITY to MIN and use the FREQUENCY buttons to set the COMPLEX EFFECT is a synthesis of the following three effects: required frequency.
  • Page 23: Preparing Homeopathic Remedies

    In this mode, Electromagnetic effect, Quantum Light and Bioresonance Effect work together Use a small plastic tweezers to pick up the homeopathic sugar pills as the specialist is not synergistically, but the Electroacupuncture effect” mode does not work. allowed to touch the remedies so as not to transfer contaminated energetic information to the sugar pills.
  • Page 24: Making Homeopathic Homaccords Using The Es

    homeopathic remedies digitally while in circuit – the effects of this will last 3 days in the visitor as MAKING HOMEOPATHICS FROM ES this will get stored in the «PLASMA MEMORY». 4. Choose the remedies from the ELECTRONIC SELECTOR that you want on the various levels IMPRINTING HOMEOPATICS FOR 5-7 MINUTES –...
  • Page 25: Certificate Of Acceptance

    11. ENVIRONMENT PROTECTION 13. MANUFACTURER’S WARRANTY The manufacturer guarantees that wellness device “DeVita Professional” conforms to the (For the EU members and other European countries, where the rules for separate waste specifications during observation of rules of consumer use, transportation and storage.
  • Page 26 14. APPENDIX Note the meaning of below terms used in the manual: Note the meaning of below terms used in the manual: THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS THERAPY = HEALTH IMPROVEMENT and DIAGNOSTICS = PROGNOSIS OF HEALTH STATUS...