Download Print this page

Advertisement

Quick Links

REVERSO
Instructions of use and maintenance page 2
Electric and refrigerating diagrams page 3
Manual of the thermostat page 4 - 6
Spare parts page 7
Rue Charles Hermite Z.I. des Sables BP 59
54110 Dombasle sur Meurthe France
tel : (+33) 03 83 45 82 82 - fax : (+33) 03 83 45 82 93
e-mail : commercial.vcs@vauconsant.com
export@vauconsant.com
1

Advertisement

loading

Summary of Contents for Vauconsant REVERSO

  • Page 1 Manual of the thermostat page 4 - 6 Spare parts page 7 Rue Charles Hermite Z.I. des Sables BP 59 54110 Dombasle sur Meurthe France tel : (+33) 03 83 45 82 82 - fax : (+33) 03 83 45 82 93 e-mail : commercial.vcs@vauconsant.com export@vauconsant.com...
  • Page 2: Installation

    Fluorescent tub : a switch on/off Positionner le commutateur sur la position 0 pour arrêter le Controls located on the control’s panel fonctionnement du reverso. Protection By main power fuse holder. Dry Bain-marie function 150 mm deep gastronorm GN 1/1 trays should be INSTALLATION used.
  • Page 3: Electric Diagram

    ELECTRIC DIAGRAM REFRIGERATING DIAGRAM CAPTION DIAGRAMS Ballast Rb Self-evaporating tray heating element Compressor Rd Defrost heating element Ca Capillary Starter Cd Condensor Sn Level probe Relief valve Atmosphere temperature probe Dh Drier Tb Safety thermostat for self evaporating tray Evaporator Fluorescent tub 4 positions switch Thermostat XR40...
  • Page 4 MANUAL OF THERMOSTAT XW40L HOW TO UNLOCK THE KEYBOARD Please read this manual before using 1.AVERTISSEMENT Keep the and the keys pressed together for • Warning: disconnect all electrical connections before more than 3 s. The "POn" message will be displayed any kind of maintenance.
  • Page 5 3.9 To enter in parameters list Pr2 All the alarm messages are showed alternating with the room To reach the parameters present in "Pr2" (parameters temperature except for the “P1” which is flashing. To reset the accessible to the technicians), please contact “EE”...
  • Page 6 MANUAL OF THERMOSTAT XT110C 3.3 To change the set point Please read this manual before using Hold pushed the SET key for 3s to change the Set 1.AVERTISSEMENT point value • Warning: disconnect all electrical connections before The value of the set point will be displayed and the LED1 & 2 any kind of maintenance.
  • Page 7: Spare Parts

    Fluorescent tub 893 mm 30 W 06.4784 Fluorescent tub 966 mm 36 W 06.4786 Fluorescent tub 1196 mm 36 W 06.4810 Ballast 15 W 06.4811 Ballast 30 W 06.4812 Ballast 36 W Francis LECOMTE Fax : 03 83 45 82 75 e-mail : sav@vauconsant.com...