Vortex Setur-M User Manual

Hydraulic turbine

Advertisement

SETUR-m
Hydraulic Vortex Turbine
user's manual
Vortex Hydrokinetics LLC © 2019
SETUR-M User's Manual - Rev. 2M-A
Page 1 of 24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Setur-M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vortex Setur-M

  • Page 1 SETUR-m Hydraulic Vortex Turbine user's manual Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 1 of 24...
  • Page 2: Welcome To Setur

    Welcome to SETUR Congratulations on your purchase of the SETUR-M Hydraulic Vortex Turbine. We believe you will find it easy to install, moreover, we are confident you will experience years of dependable service. SETUR turbine has been designed and precision manufactured to provide the most practical and user- friendly system currently available for renewable energy electricity generation.
  • Page 3: Safety

    Installation of the SETUR turbine should only be undertaken by suitably competent and qualified personnel. SETUR-M turbine installation does not require specialized tools and lifting equipment. The inverter included with your turbine may only be installed, maintained, repaired and connected with the SETUR turbine and the electric grid by a trained and qualified electrician.
  • Page 4: Electrical Safety Hazards

    ➢ Only an authorized electrician is permitted to connect this equipment to the public grid. The SETUR-M turbine generates a 3-phase alternating current (AC) which is then rectified to direct current (DC), then inverted into a pure sine wave single-phase 220-240 V (110-120 V USA model) alternating current (AC).
  • Page 5: Exclusion Of Liability

    Modifications to the turbine and/or inverter are prohibited. The turbine and inverter may only be used if safe to operate and in technically perfect condition. Only a duly authorized representative of Vortex Hydrokinetics LLC may open the hermetically sealed generator and magnetic coupling enclosures of the turbine.
  • Page 6: Table Of Contents

    Trademark and copyright notice Safety Mechanical safety hazards Electrical safety hazards Exclusion of liability Table of content - SETUR-M turbine: Description and Specifications - Specifications and operating environment Limited lifetime warranty - Warranty exclusions - Procedures for obtaining warranty service Serial numbers...
  • Page 7: Setur-M Turbine: Description And Specifications

    SETUR-M TURBINE: DESCRIPTION AND SPECIFICATIONS Your SETUR-M bladeless turbine is an environmentally friendly device that uses vortex phenomenon to harness the kinetic energy of water flow in order to produce electricity. SETUR turbine can be cost- effectively used as a standalone self-contained system or in multi-unit hydropower farms.
  • Page 8: Specifications And Operating Environment

    Limited Lifetime Warranty Noise < 50 dBA IMPORTANT! SETUR turbine must be fully submerged in water to ensure that vortex occurs. Alternatively, the water can be routed to the turbine via a pipe or an aqueduct. Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev.
  • Page 9: Limited Lifetime Warranty

    Vortex Hydrokinetics LLC warrants to the original consumer purchaser of a Vortex Hydrokinetics LLC SETUR turbine that it will, at its option, repair or replace such product if it is found by Vortex Hydrokinetics LLC, in its sole judgment, to be defective under normal residential use, provided that it has been installed and maintained in accordance with Vortex Hydrokinetics LLC’s instructions.
  • Page 10 It will also be null and void if there are indications of misuse and/or abuse. Vortex Hydrokinetics LLC has the option of voiding the warranty if any one other than a Vortex Hydrokinetics LLC technician attempts to service the product without the explicit authorization in writing.
  • Page 11: Procedures For Obtaining Warranty Service

    RMA number you have obtained to the address provided by the technical personnel. 6. Upon receiving the product, Vortex Hydrokinetics LLC will inspect it, and if found covered under this limited warranty, repair or replace your product (at Vortex Hydrokinetics LLC’s discretion) and will ship it back to you within 4-12 weeks (depends on parts availability).
  • Page 12: Serial Numbers

    ➢ Appropriate intake screen should be installed to prevent any mechanical damage to the turbine by any debris that might be in water. Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 12 of 24...
  • Page 13: Getting Ready

    4. power cables. GETTING READY Upon receipt of the turbine, unless purchased from and installed by the authorized Vortex Hydrokinetics LLC distributor/dealer, make sure that all boxes are not damaged. Check part conformity with the delivery list and ensure there are no damaged or defective parts; should there be any, please inform Vortex Hydrokinetics LLC immediately.
  • Page 14: Electrical Work

    ➢ Only an authorized electrician is permitted to connect this equipment. SETUR-M turbine generates a 3-phase alternating current (AC) which is then rectified to direct current (DC), then inverted into a pure sine wave single-phase 220-240 V (110-120 V USA model) alternating current (AC).
  • Page 15: System Electrical Configuration And Wiring

    WARNING! An electric shock can be fatal. High danger due to grid voltage and voltage from the turbine that is operational. SYSTEM WIRING Each SETUR-M inverter is equipped with two Power Outlets, North-American 110V-120V and Universal 220V-240V. To connect the turbine to your house...
  • Page 16 NEVER work on your renewable energy system with the turbine in operation. Vortex Hydrokinetics LLC will not be liable if you get electrocuted, injured or killed due to connecting this system by yourself and/or disregarding the warnings and instructions provided in this and inverter's user's manuals, or if you connect this equipment incorrectly and in doing so damage other equipment in your system.
  • Page 17: Site Selection

    Higher hydraulic head is the least expensive way to generate more power. SETUR-M requires only 4 m/s (max 11 m/s) of water flow velocity which corresponds to approximately 1 m (max 6 m) of hydraulic head, and at least 65 l/s of water flow rate.
  • Page 18 Since the SETUR turbine requires a head of only 1 m (max 6 m) to generate nominal power output, measuring should not be difficult and needs no additional explanation. Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 18 of 24...
  • Page 19 Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 19 of 24...
  • Page 20 Strictly follow the instructions of the battery manufacturer. Properly maintained SETUR system will run reliably for many years. Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 20 of 24...
  • Page 21 In case you choose to route the water to your turbine via a pipe or an aqueduct, you should take care to ensure that the exhaust water from the turbine returns to the water source e.g. river, stream, canal. Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 21 of 24...
  • Page 22: Turbine Mounting

    In case the water is delivered to the turbine via a pipe, it must have a on/off valve. Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 22 of 24...
  • Page 23: Operating Your Setur System Efficiently - Maintenance

    If the turbine's moving parts have substantial algae growth or fouling, you may power wash or soft-brush clean the affected parts or the entire turbine. Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 23 of 24...
  • Page 24: Contact Details

    Vortex Hydrokinetics LLC 1825 NW Corporate Blvd | Ste 110 Boca Raton | FL 33431 | USA Tel: +1 561 801-7698 Fax: +1 561 807-9058 e-mail: support@vortexhydro.com Vortex Hydrokinetics LLC © 2019 SETUR-M User's Manual - Rev. 2M-A Page 24 of 24...

This manual is also suitable for: