Analogue Meters With Moving - Iron Movement RI 10 Analog - Digital Insulation Tester ( User Manual) www.ziegler-instruments.com IC 15030858...
Page 2
(3)Push button (11) Display for selected function (4)Push button (12) Display for the unit of (5)TEST Push button measured quantity RI 10 (6)Function selector switch (13) Over range Indication (7)Terminal sockets (14) Pointer for Analog indication (8)Symbol for (15) Scale for Analog Indication “CONTINUOUSLY ON”...
Page 3
The RI 10 Analog-Digital Insulation Tester is manufactured in work must be performed by a qualified person, who understands the compliance with safety regulations IEC 61010-1/EN 61010-1/VDE 0413 danger involved.
·Select the required "Test Voltage (50V/100V/250V/500V/1000V)" by changing the "Function Selector Switch". ·Connect the test probes firmly to the circuit under test. RI 10 Note ! Insulation resistance can only be measured at voltage free object. Hence the circuit under test must be switched off, de-energized and isolated before carrying out any insulation resistance measurement.
Page 5
MIN and MAX MAX flash Stored MAX value values are displayed 3. Return short Same as 1. Same as 1. Stored values are Same as 1. to 1. not cleared long Cleared Reset Cleared Cleared www.ziegler-instruments.com...
Continuity Test Continuity Testing and Resistance Measurement Attention ! RI 10 Be absolutely certain that the device under test is voltage-free. Continuity Testing Verify that device under test is electrically dead. Set the function selector switch to “ ” position.
Structure of command menu for Insulation measurement : Additional features available in Insulation measurement ranges. Basic Minium and Maximum value “MIN/MAX” storage Display Voltage Measurement nnnn RI 10 mm:ss 500V 250V 100V xxxx Structure of command menu for Resistance & Continuity measurement...
Page 8
By triangle (13) 500V 0.00 5 MW Digital 500 MW 1000V 0.00 Display/Char. Height 7 segment digits/12mm Number of Digits 3 digit for M and 00 W 0.00 4 digit for Stop watch Cont 0.00 Over range Indication www.ziegler-instruments.com | 10...
Page 9
Protection Instrument :IP 50 For terminal socket : IP 20 according to DIN VDE 0470 Part 1 / EN60529 Dimensions W x H x D 84mm x 195 mm x 35 mm Weight 500 g including battery www.ziegler-instruments.com | 10...
Page 10
If display = “FUSE” : Fuse is blown and needs replacement. Note : Once “FUSE” is displayed all the functions are inhibited. Immediately switch the Instrument OFF and replace the fuse. ZIEGLER INSTRUMENTS Schnepfenreuther Weg 6, D-90425 Nürnberg, Germany. (+49)(911) 38 492 45 info@ziegler-instruments.com...