4.10.
The inverter monitors the following potentially hazardous conditions:
4.10.1. low Battery Voltage - this condition is not harmful to the inverter but could damage the power source. the inverter automatically
shuts down when input voltage drops to 10.5V. When the condition is corrected, the unit may be restarted.
4.10.2. short circuit - reverse polarity or short circuit of the load will usually result in the opening of the short circuit protection and blowing
the fuse(s). As the fuses are internal we recommend contacting your local repair agent or sealeys technical help line directly
on 01284 757505 for guidance.
4.10.3. High Temperature - When the temperature of the internal heat sink reaches 65°C, the solid state temperature sensor will
automatically shut the unit down. once it is allowed to cool, the unit may be restarted.
5. TROUBLE SHOOTING
Problem
unit will not operate
low output voltage.
overload led illuminates.
television Interference
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTy: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INfORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
© Jack sealey limited
Power led
on/off switch
Possible Cause
1. Poor dc contact
2. Battery voltage below 10.5V.
3. load draws too much power.
4. Inverter in thermal shutdown.
5. Vehicle battery in poor condition.
6. Fuses blown due to short circuit.
check with voltmeter.
unit overloaded.
Inverter too close to the television.
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk,
IP32 7AR
Original Language Version
Fault led
13A socket
usB Port
1. check all dc contacts.
2. recharge or replace battery.
3. reduce load.
4. Allow inverter to cool.
5. check / replace battery.
6. contact local repair agent or sealey technical
use true rms voltmeter.
switch off and reduce load.
locate the inverter as far as possible from the
tV, antenna and other cables.
Environmental Protection
WEEE Regulations
01284 757500
01284 703534
PsI300.V2 : PsI600.V2 : PsI800.V2 : PsI1000.V2
fig.4
Suggested Remedy
help line for guidance.