L85EX Lighting fixture
Installation and maintenance manual
Perimeter light
Aeronautical Obstruction light
/i
ORGA BV
Strickledeweg 13
3125 AT SCHIEDAM
The Netherlands
T +31 (0) 10 208 5555
E info@Orga.nl
I www.orga.nl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L85EX and is the answer not in the manual?

Questions and answers

Summary of Contents for ORGA L85EX

  • Page 1 L85EX Lighting fixture Installation and maintenance manual Perimeter light Aeronautical Obstruction light ORGA BV Strickledeweg 13 3125 AT SCHIEDAM The Netherlands T +31 (0) 10 208 5555 E info@Orga.nl I www.orga.nl...
  • Page 2 Copyright 2016 Orga. All rights reserved. Disclaimer While every effort has been made to provide a complete, up-to-date, accurate manual, Orga will accept no liability claims for damages resulting from any errors or omissions in this manual.
  • Page 3: Table Of Contents

    Connect the power supply cable ................16 1.4.4 Connect the wiring of the lighting fixture ..............17 1.4.5 Close the cover assembly ..................18 Installation of L85EX Recessed ................... 19 1.5.1 Open the cover assembly ..................19 1.5.2 Connect the power supply cable ................19 1.5.3...
  • Page 4 EC-Type Examination certificate L85EX ................55 IECEx CERTIFICATE ..................59 IECEx Certificate of Conformity L85EX ................59 EC - Declaration of Conformity ................. 65 EC - Declaration of Conformity L85EX ................65 Ex CERTIFICATE ....................67 Ex Certificate of Conformity L85EX (optional) ..............67...
  • Page 5: Introduction

    • Troubleshooting Before you begin Before you start with the installation, operation, maintenance or troubleshooting on the Lighting fixture L85EX: WARNING Do not continue before you understand the content of this manual. Familiarize yourself with the content on this manual.
  • Page 6: Icons Used In This Document

    INTRODUCTION Icons used in this document The icons below are used in this document to indicate danger or to give extra information. WARNING Can cause personal injury. WARNING Electrical danger. Can cause personal injury. CAUTION Can cause damage to the equipment. NOTE Gives further/extra information.
  • Page 7: Safety

    SAFETY SAFETY Intended use The L85EX must only be used at offshore helicopter decks as perimeter light or as aeronautical obstruction light. The lantern complies with the CAP437, ICAO annex 14 and the IMO MODU Code. The red type of lantern also complies to the CAP168 regulations and the Dutch Mining Regulations.
  • Page 8: Installation

    WARNING Make sure you comply with the (pre)conditions for electrical systems in explosive atmospheres. CAUTION The L85EX is suitable for use in locations with a low risk of mechanical danger. Operation There are no specific safety precautions necessary. Maintenance and repair...
  • Page 9: Warranty Policy

    REPRESENTATIVE. LIMITED WARRANTY (a) ORGA warrants, subject to the following limitations, that at time of delivery to Buyer, its Products will conform to applicable ORGA drawings and Product specifications and will be free from defects in workmanship and material. Ifapplicable, ORGA warrants that at the time of delivery Products are compliant to applicable national and/or international rules and regulations.
  • Page 10 Goods of 11 April 1980 (Weens Koopverdrag) do not apply, nor does any future international regulation concerning the purchase of moveable property of which parties can make use. (h) Orga reserves the right to modify its warranty at any time, at its sole discretion. Version 2.1...
  • Page 11: Description

    Power supply cable to control panel Clamping ring 1.1.1 Description The lighting fixture or aeronautical obstruction light, L85EX marks the offshore helicopter deck and obstructions for aviation traffic.The perimeter light is steady burning. The lighting fixture is explosion proof. Version 2.1...
  • Page 12: Overview Of The Recessed Version

    DESCRIPTION Overview of the recessed version Dome Cover assembly Housing Control unit Power supply cable to control panel (not supply of scope) Clamping ring Version 2.1...
  • Page 13: Product Types

    Product types Type number Description Type number Description L85EX-G-AC Green, 30cd (60cd max.) L85EX-G-DC Green, 30cd (60cd max.) L85EX-G-AC-RE Green, 30cd (60cd max.) L85EX-G-DC-RE Green, 30cd (60cd max.) L85EX-R-AC-10 Red, 10cd minimum L85EX-R-DC-10 Red, 10cd L85EX-R-AC-32 Red, 32 cd minimum L85EX-R-DC-32...
  • Page 14 DESCRIPTION Version 2.1...
  • Page 15: Installation

    Unpack the delivery Check if the delivery is complete. Refer to the Appendix. Check your delivery on damage. Report damages or missing parts immediately to Orga. Refer to the contact information on the last page. Preparation Collect the correct installation materials. These are not included in the delivery: •...
  • Page 16: Installation Of L85Ex

    • Keep an open space of 1 m around the light fixture for maintenance pur- poses. Orga advises to install the light fixture according to the procedure below: Install the light fixture with the cables sideways (because of the looping).
  • Page 17: Connect The Wiring Of The Lighting Fixture

    INSTALLATION 1.4.4 Connect the wiring of the lighting fixture Note The procedure below applies to each lighting fixture on the platform. Looping of the lighting fixture WARNING Only use cable lugs of the eyelet type. Connect the live wire of the cables with terminal L.
  • Page 18: Close The Cover Assembly

    INSTALLATION Connect the metric M6 connection on the foot of the base with an earth cable mounting bolt (A) to a grounded structure on the platform. Place the earthing tag (E) on the base. Use a PE wire with a cross-sectional area of at least 4 mm with a supplied cable lug (D).
  • Page 19: Installation Of L85Ex Recessed

    INSTALLATION Installation of L85EX Recessed 1.5.1 Open the cover assembly Open the cover assembly. Refer to section 2.3. 1.5.2 Connect the power supply cable Fasten the power supply cable with the cable gland (A) Close the second cable entry with a blind plug (B).
  • Page 20: Close The Cover Assembly

    The light fixture must be installed on a rigid, horizontal surface, in a posi- tion that meets the specific visibility requirements. • Keep sufficient open space around the light fixture for maintenance pur- poses. Orga advises to install the light fixture according to the procedure below: Version 2.1...
  • Page 21 INSTALLATION Install the light fixture (A) in the cavity (B) with the cables. For a specification of the cavity sizes, refer to 5.3.1. Fasten the cover assembly (A) to the surface with M8 fasteners (B), a suitable spring lock washer (C) and washer (D). Make sure that the light fixture is horizontally levelled.
  • Page 22 INSTALLATION Version 2.1...
  • Page 23: Access To Parts

    ACCESS TO PARTS ACCESS TO PARTS Open the cover assembly WARNING Make sure that the equipment is de-energized: On the control panel, turn the mains power switch to the OFF position. Switch off the mains power supply. Loosen the four bolts (A) and the washers (B) and (C).
  • Page 24: Open The Cover Assembly Of The Recessed Version

    ACCESS TO PARTS Open the cover assembly of the recessed version WARNING Make sure that the equipment is de-energized: On the control panel, turn the mains power switch to the OFF position. Switch off the mains power supply. Remove the four bolts (A) and the washers (B) and (C).
  • Page 25: Maintenance

    Domes Visual inspection on con- Every 12 months Clean. Refer to 3.2.1. tamination Visual inspection on Every 12 months Contact Orga. scratches and other dam- Base Visual inspection of the Every 12 months Contact Orga. coating on damage and corrosion...
  • Page 26 MAINTENANCE Version 2.1...
  • Page 27: Troubleshooting

    TROUBLESHOOTING Failure of the light fixture The table below gives the possible problems and its solution. If the problem is not listed below, contact Orga BV. WARNING Only an electrical engineer is allowed to do maintenance on the electrical system.
  • Page 28: Check The Electrical Connections

    TROUBLESHOOTING Check the electrical connections WARNING Only an electrical engineer is allowed to do maintenance on the electrical system. CAUTION Use proper tooling to prevent damage on the material that is installed. 4.2.1 Check the internal connections (control unit to LEDs) Open the cover assembly, see section 2.
  • Page 29: Replace The Dome

    TROUBLESHOOTING Open the cover assembly, see section 2. Check if the electrical connections in the L(+) housing are tight. N(-) • Connection to terminal L (+). • Earth connection PE. • Connection to terminal N (-). • Earth connection (A) in the housing. If necessary, correct the connection(s).
  • Page 30 TROUBLESHOOTING Version 2.1...
  • Page 31: Technical Data

    TECHNICAL DATA TECHNICAL DATA Mechanical specification 5.1.1 Perimeter light L85EX-G-AC Explosion proof LED perimeter light Table 1 Standards and certification Standards/Certification Certified to CAA-UK CAP 437; Offshore helicopter landing areas - Guidance on standards, 7th edition, chapter 4, paragraph 3.1 Certified to IMO standard MODU code;...
  • Page 32 TECHNICAL DATA Table 4 Physical characteristics Dimensions (L x W x H) 161 x 161 x 111 mm Weight 3.6 kg Design degree of protection IP66 Operating temperature range -40 ºC to +60 ºC ATEX/IECEx Operating temperature range -50 ºC to +45 ºC Inmetro Version 2.1...
  • Page 33: Perimeter Light L85Ex-G-Ac-Re

    TECHNICAL DATA 5.1.2 Perimeter light L85EX-G-AC-RE Explosion proof LED Perimeter light. Table 5 Standards and certification Standards/Certification Certified to CAA-UK CAP 437;Offshore helicopter landing areas - Guidance on standards,7th edition, chapter 4,paragraph 3.1 Certified to IMO standard MODU code; 2009 (Edition 2010),chap- ter 13.5.21...
  • Page 34: Aeronautical Obstruction Light L85Ex-R-Ac-10

    TECHNICAL DATA 5.1.3 Aeronautical obstruction light L85EX-R-AC-10 Explosion proof LED aeronautical obstruction light. Table 9 Standards and certification Standards/Certification Certified to ICAO Annex 14, volume l; 5th Edition, November2009, chapter 6.3.2 – Type A low intensity obstacle light Certified to IMO standard MODU code; 2009 (Edition 2010),chap- ter 13.5.24...
  • Page 35 TECHNICAL DATA Table 12 Physical characteristics Dimensions (L x W x H) 161 x 161 x 111 mm Weight 3.6 kg Degree of protection IP66 Operating temperature range -40 ºC to +60 ºC ATEX/IECEx Operating temperature range -50 ºC to +45 ºC Inmetro Version 2.1...
  • Page 36: Aeronautical Obstruction Light L85Ex-R-Ac-32

    TECHNICAL DATA 5.1.4 Aeronautical obstruction light L85EX-R-AC-32 Explosion proof LED aeronautical obstruction light. Table 13 Standards and certification Standards/Certification Certified to ICAO Annex 14, volume l; : Aerodrome design and operation, 6th Edition, 2013, chapter 6.3.2 - Type B low intensity...
  • Page 37: Aeronautical Obstruction Light L85Ex-R-Ac-50

    TECHNICAL DATA 5.1.5 Aeronautical obstruction light L85EX-R-AC-50 Explosion proof LED aeronautical obstruction light. Table 17 Standards and certification Standards/Certification Cenelec EN 60079-0, EN 60079-7 and EN 60079-18 SIRA 12ATEX3066 X; ATEX II 2G Ex e mb IIC T4 Gb IEC 60079-0, IEC 60079-7 and IEC 60079-18 IECEx SIR 12.0026 X;...
  • Page 38: Aeronautical Obstruction Light L85Ex-R-Ac-200

    TECHNICAL DATA 5.1.6 Aeronautical obstruction light L85EX-R-AC-200 Explosion proof LED aeronautical obstruction light. Table 21 Standards and certification Standards/Certification Complies with CAA-UK CAP 437;Offshore helicopter landing areas - Guidance on standards, 7th edition Feb 2013, chapter 4,paragraph 4.4 Cenelec EN 60079-0, EN 60079-7 and EN 60079-18 SIRA 12ATEX3066 X;...
  • Page 39: Perimeter Light L85Ex-B-Ac

    TECHNICAL DATA 5.1.7 Perimeter light L85EX-B-AC Explosion proof LED perimeter light Table 25 Standards and certification Standards/Certification In line with API (American Petroleum Institute), Recommended practice for Planning, Designing, and Constructing Heliports for Fixed Offshore Platforms; RP 2L, 1996, chapter 5.10...
  • Page 40: Perimeter Light L85Ex-Y-Ac

    TECHNICAL DATA 5.1.8 Perimeter light L85EX-Y-AC Explosion proof LED perimeter light Table 29 Standards and certification Standards/Certification In line with API (American Petroleum Institute), Recommended practice for Planning, Designing, and Constructing Heliports for Fixed Offshore Platforms; RP 2L, 1996, chapter 5.10...
  • Page 41: Perimeter Light L85Ex-G-Dc

    TECHNICAL DATA 5.1.9 Perimeter light L85EX-G-DC Explosion proof LED perimeter light Table 33 Standards and certification Standards/Certification Certified to CAA-UK CAP 437;Offshore helicopter landing areas - Guidance on standards,7th edition, chapter 4,paragraph 3.1 Certified to IMO standard MODU code; 2009 (Edition 2010),chap- ter 13.5.21...
  • Page 42: Perimeter Light L85Ex-G-Dc-Re

    TECHNICAL DATA 5.1.10 Perimeter light L85EX-G-DC-RE Explosion proof LED perimeter light Table 37 Standards and certification Standards/Certification Certified to CAA-UK CAP 437;Offshore helicopter landing areas - Guidance on standards, 7th edition, chapter 4,paragraph 3.1 Certified to IMO standard MODU code; 2009 (Edition 2010),chap- ter 13.5.21...
  • Page 43: Aeronautical Obstruction Light L85Ex-R-Dc-10

    TECHNICAL DATA 5.1.11 Aeronautical obstruction light L85EX-R-DC-10 Explosion proof LED aeronautical obstruction light. Table 41 Standards and certification Standards/Certification Certified to ICAO Annex 14,volume l; Aerodrome design andoper- ations, 6th Edition, 2013, chapter 6.3.2 - Type A low intensity obstacle light Certified to IMO standard MODU code;...
  • Page 44 TECHNICAL DATA Table 44 Physical characteristics Dimensions (L x W x H) 161 x 161 x 111 mm Weight 3.6 kg Degree of protection IP66 Operating temperature range -40 ºC to +60 ºC ATEX/IECEx Operating temperature range -50 ºC to +45 ºC Inmetro Version 2.1...
  • Page 45: Aeronautical Obstruction Light L85Ex-R-Dc-32

    TECHNICAL DATA 5.1.12 Aeronautical obstruction light L85EX-R-DC-32 Explosion proof LED aeronautical obstruction light. Table 45 Standards and certification Standards/Certification operations, 6th Edition, 2013, chapter 6.3.2 - Type B low intensity obstacle light Certified to IMO standard, MODU code; 2009 (Edition 2010), chapter 13.5.24...
  • Page 46: Aeronautical Obstruction Light L85Ex-R-Dc-50

    TECHNICAL DATA 5.1.13 Aeronautical obstruction light L85EX-R-DC-50 Explosion proof LED aeronautical obstruction light. Table 49 Standards and certification Standards/Certification Cenelec EN 60079-0, EN 60079-7 and EN 60079-18 SIRA 12ATEX3066 X; ATEX II 2G Ex e mb IIC T4 Gb IEC 60079-0, IEC 60079-7 and IEC 60079-18 IECEx SIR 12.0026 X;...
  • Page 47: Aeronautical Obstruction Light L85Ex-R-Dc-200

    TECHNICAL DATA 5.1.14 Aeronautical obstruction light L85EX-R-DC-200 Explosion proof LED aeronautical obstruction light. Table 53 Standards and certification Standards/Certification Complies with CAA-UK CAP 437;Offshore helicopter landing areas - Guidance on standards, 7th edition Feb 2013, chapter 4,paragraph 4.4 Cenelec EN 60079-0, EN 60079-7 and EN 60079-18 SIRA 12ATEX3066 X;...
  • Page 48: Perimeter Light L85Ex-B-Dc

    TECHNICAL DATA 5.1.15 Perimeter light L85EX-B-DC Explosion proof LED perimeter light Table 57 Standards and certification Standards/Certification In line with API (American Petroleum Institute), Recommended practice for Planning, Designing, and Constructing Heliports for Fixed Offshore Platforms; RP 2L, 1996, chapter 5.10...
  • Page 49: Perimeter Light L85Ex-Y-Dc

    TECHNICAL DATA 5.1.16 Perimeter light L85EX-Y-DC Explosion proof LED perimeter light Table 61 Standards and certification Standards/Certification In line with API (American Petroleum Institute), Recommended practice for Planning, Designing, and Constructing Heliports for Fixed Offshore Platforms; RP 2L, 1996, chapter 5.10...
  • Page 50: Accessories

    TECHNICAL DATA Accessories 5.2.1 Swivel elbow adapter for cable gland (optional for recessed versions) Explosion proof LED aeronautical obstruction light. Table 65 Supported types Hawke 492/493 swivel elbow Certificate SIRA 11ATEX1347U / IECEx SIR 11.0152U Special conditions for safe use: •...
  • Page 51: Labels

    This label is an example. The actual label may vary and is dependant of the version of your product. Strickledeweg 13 NL - 3125AT Schiedam T +31 (0)10 208 5555 0344 info@orga.nl - www.orga.nl XXXXXXXXXXXXXXXXX XX-XXVac; XX-XXHz XX W; XVA Ex e mb IIC Tx Gb II 2G...
  • Page 52: Labels

    This label is an example. The actual label may vary. Strickledeweg 13 NL - 3125AT Schiedam T +31 (0)10 208 5555 info@orga.nl - www.orga.nl OCP 0034 NCC: xx.xxxx X Ex e mb IIC Tx Gb -XX °C ≤ Ta ≤+XX °C /IP66...
  • Page 53: Delivery And Spare Parts

    DELIVERY AND SPARE PARTS Delivery information L85EX Amount Description L85EX base Housing Control unit Cover assembly Bolt Spring lock washer Washer Earth cable mounting screw Spring lock washer Washer Earthing tag L85EX cover assembly Including grease. Always lubricate after opening the lamp.
  • Page 54: Spare Parts

    Includes O-ring and adhesive. Always apply before closing the lamp. Control unit for L85EX-G/B-AC (LPS8511-R0920) 071821 Includes O-ring and adhesive. Always apply before closing the lamp. Control unit for L85EX-R-AC-10 & L85EX-Y-AC (LPS8511-R0930) 071822 Includes O-ring and adhesive. Always apply before closing the lamp. Control unit for L85EX-R-DC50/200 (LPS2411-R1200) 074998 Includes O-ring and adhesive.
  • Page 55: Batex Certificate

    EC-Type Examination certificate L85EX EC TYPE-EXAMINATION CERTIFICATE Equipment intended for use in Potentially Explosive Atmospheres Directive 94/9/EC Certificate Number: Sira 12ATEX3066 Issue: Equipment: L85EX-x-xx-xx Range of LED Lighting Fixtures Applicant: Orga B.V. Address: Strickledeweg 13 3125 AT Schiedam The Netherlands This equipment and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to.
  • Page 56 L85EX consists of a rectangular stainless steel body with non-metallic dome lens and clamping ring. Four mounting feet are formed as part of the base for floor mounting. The L85EX consists of an encapsulated power supply mounted within the metallic body with increased safety terminals and an increased safety LED light engine.
  • Page 57 SCHEDULE EC TYPE-EXAMINATION CERTIFICATE Sira 12ATEX3066 Issue 5 Issue 3 of the certificate introduced the Type 200cd setup, which is now included in original temperature range table. iii. It was recognised that these devices can have up to two M16, M20, M25, 1/2” NPT or 3/8” NPT cable entries located in the underside of the Lighting Fixture base.
  • Page 58 100 ms. 17.7 The L85EX-x-xx-xx Range of LED Lighting Fixtures incorporates previously certified devices, it is therefore the responsibility of the manufacturer to continually monitor the status of the certification associated with these devices, and the manufacturer shall inform Sira of any modifications of the devices that may impinge upon the explosion safety design of their products.
  • Page 59: Ciecex Certificate

    IECEx CERTIFICATE IECEx Certificate of Conformity L85EX Version 2.1...
  • Page 60 Version 2.1...
  • Page 61 Version 2.1...
  • Page 62 Version 2.1...
  • Page 63 Version 2.1...
  • Page 64 Version 2.1...
  • Page 65: Dec - Declaration Of Conformity

    EC - Declaration of Conformity EC - Declaration of Conformity L85EX EU-Declaration of Conformity Wij, Orga BV, verklaren geheel onder eigen verantwoordelijkheid dat het product We, Orga BV, declare under sole responsibility that the product LED LIGHTING FIXTURES type L85EX-x-xx...
  • Page 66 Version 2.1...
  • Page 67: Ex Certificate

    Ex CERTIFICATE Ex Certificate of Conformity L85EX (optional) Certificado de Conformidade Ex Ex Certificate of Conformity Modelo com Avaliação do Sistema de Gestão da Qualidade do Processo de Produção e Ensaios no Produto Model with Assessment of Quality Management System of Production Process and Test on Product Certificado Nº:...
  • Page 68 3 NCC 12.1223 Certificate Nº: Data de emissão: Página 2 de 5 31-03-2016 Issued date: Page 2 of 5 Orga B.V. Fabricante: Strickledeweg 13, Schiedam, 3125 AT Manufacturer: Holanda Unidades fabris adicionais: Additional manufacturing locations: Este certificado é emitido como uma verificação que amostras, representativas da linha de produção, foram avaliadas e ensaiadas e atenderam às normas relacionadas abaixo, e que o sistema de gestão da qualidade do fabricante, relativo aos produtos Ex cobertos por este certificado, foi...
  • Page 69 Certificado de Conformidade Ex Ex Certificate of Conformity Modelo com Avaliação do Sistema de Gestão da Qualidade do Processo de Produção e Ensaios no Produto Model with Assessment of Quality Management System of Production Process and Test on Product Certificado Nº: Emissão/issue nº.: 3 NCC 12.1223...
  • Page 70 Table Identificação Revisão Identificação Revisão Identificação Revisão Identification Issue Identification Issue Identification Issue SW-0004454 16/04/2013 LPS2411-EL02R0 LED3501-EP01 SW-0004460 16/04/2013 LPS2411-EL03R0 L85EX-200CD-IW-01 SW-0004461 16/04/2013 LPS2411-EL04R0 LPS2411-EL01R0 SW-0004462 16/04/2013 LPS2411-EL05R0 L85EX-IW-01r0 LED3501-EL01 LPS2411-ES01R0 LED8508-EP01R0 LED3501-EL02 LPS2411-EP01R1 LPS8511-ES01R2 FNCC_205 Rev. 14 Version 2.1...
  • Page 71 Identification Issue Identification Issue 5144-APPR-AA01 5144-APPR-AA51 LED3508-EL01 LED3501-EL03 5144-APPR-AA61 5144-APPR-AA61 5144-APPR-B31 SW-0003863 SW-0003897 5144-APPR-B01 SW-0003898 015335 LPS8511-EL01 SW-0003874 Instruções sobre o L85EX 27/07/2015 LPS8511-EL04 LED3508EX 07/02/2012 SW-0002433 LPS8511-EL02 LPS8511-EP01R2 5144-APPR-AA04 LED3508-EL03 LPS8511-EL05 5144-APPR-AA03 LED3508-EL02 LPS8511-EL03 APPR-AA71 LED3501-EL04 5144-APPR-B21 SW-0003873 5144-APPR-AA02...
  • Page 72 For information about maintenance or repair that is not in this manual, please contact the Orga service support department. ORGA BV Strickledeweg 13 3125 AT SCHIEDAM The Netherlands +31 (0) 10 208 5550 servicedesk@orga.nl www.orga.nl...

Table of Contents