Installation Guide Notice This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.
Installation Guide Table of Contents 1. Introduction ....................12 Evolution IP-20LH Hardware Options ................13 2. Evolution IP-20LH Hardware Overview ............14 Slot Population Guidelines ................... 15 Traffic Control Card (TCC) ................... 18 Radio Interface Cards (RMCs) ..................19 Ethernet Line Interface Cards ..................21 2.4.1 LIC-X-E4-Elec ......................
Page 4
Establishing a Connection ................... 88 9.1.1 Connecting to the Unit with a Serial RS-232 Cable ............. 88 9.1.2 Connecting to the Unit with a TP Cable via a LAN Connection ........89 Ceragon Proprietary and Confidential Page 4 of 101...
Page 5
10.4 TDM LIC-T155 (1 x ch-STM-1) ..................98 11. Specifications ....................99 11.1 Environmental Specifications for IDU ................99 11.2 Environmental Specifications for XCVR ............... 99 11.3 Mechanical Specifications ..................100 11.4 Power Consumption Specifications ................101 Ceragon Proprietary and Confidential Page 5 of 101...
Page 6
Do not look into coaxial connectors at closer than reading distance (30 cm). Do not look into an open waveguide unless you are absolutely sure that the power is turned off. Ceragon Proprietary and Confidential Page 6 of 101...
Page 7
Restricted Access Area: DC powered equipment should only be installed in a Restricted Access Area. Installation Codes: The equipment must be installed according to country national electrical codes. For North America, equipment must be installed in Ceragon Proprietary and Confidential Page 7 of 101...
Page 8
är kopplad till kabel-TV nät kan i vissa fall medfőra risk főr brand. Főr att undvika detta skall vid anslutning av utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen och kabel-TV nätet. Ceragon Proprietary and Confidential Page 8 of 101...
Page 9
Gefahrenrisiko: Durch Abtrennen einer Stromquelle wird nur ein Stromversorgungsmodul abgetrennt. Um die Einheit vollständig zu isolieren, trennen Sie alle Stromversorgungen ab. Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäß EN ISO 7779. Ceragon Proprietary and Confidential Page 9 of 101...
Page 11
Release Notes for the functionality supported in the specific release you are using. Target Audience This guide is intended for use by personnel of all levels certified by Ceragon personnel such as system engineers, technicians, or supervisors. Related Documents ...
The Evolution IP-20LH enables operators to deploy high capacity, long haul microwave systems in locations where rack space and shelter real-estate are limited. Evolution IP-20LH supports multi-carrier solutions of up to 8+0 ABC and IF Combining Space Diversity.
Installation Guide Evolution IP-20LH Hardware Options The Evolution IP-20LH uses the IP-20N as indoor unit (IDU). The IP-20N chassis is available in 1RU and 2RU versions, each of which supports a common set of cards for traffic, radio interface, and management: ...
Installation Guide Evolution IP-20LH Hardware Overview The Evolution IP-20LH is a modular unit based on a 1RU or 2RU chassis into which a variety of cards can be inserted for traffic, radio interface, management, and power supply. The IP-20LH backplane provides connectivity among the slots in the chassis for management, power distribution, and traffic aggregation.
1. 1RU and 2RU: Slot 2 is used to hold Ethernet LICs. 1RU and 2RU: Slots 3 through 6 3, 4, 5, 6 are used to hold RMCs or TDM LICs. Ceragon Proprietary and Confidential Page 15 of 101...
Page 16
1RU and 2RU: This slot holds Fans Drawer the fans drawer. 1RU and 2RU: This slot holds the fans drawer. The filter unit is Filter optional. The filter drawer holds a replaceable filter unit. Ceragon Proprietary and Confidential Page 16 of 101...
Interface LED The TCC is not functioning normally. Green The TCC is functioning normally. For a detailed description of the TCC’s interfaces and pin-outs, refer to TCC Interfaces and Pin-Outs on page 92. Ceragon Proprietary and Confidential Page 18 of 101...
RFU – Indicates the status of the XCVR. STM-1/OC3 – Indicates the status of the STM-1/OC3 interface. RMC LEDs RMC Interface LEDs Color Explanation The RMC is not functioning normally. Green The RMC is functioning normally. Ceragon Proprietary and Confidential Page 19 of 101...
Page 20
Blinking Green – An RF loopback has been activated and the result is OK. STM-1/OC3 interface failure (alarms STM-1/OC3 are registered). Loss of communication on the STM-1/OC3 Orange STM-1/OC3 interface. The STM-1/OC3 interface is STM-1/OC3 Green functioning normally. Ceragon Proprietary and Confidential Page 20 of 101...
LIC-X-E4-Opt Detailed View The LIC-X-E4-Opt provides the following LED: ACT – Indicates the card status. LIC-X-E4-Opt LEDs LIC-X-E4-Opt LED Color Explanation The LIC is not functioning normally. Green The LIC is functioning normally. Ceragon Proprietary and Confidential Page 22 of 101...
Evolution® IP-20LH Installation Guide TDM Line Interface Cards The Evolution IP-20LH offers the following types of TDM Line Interface Cards (TDM LICs): LIC-T16 (16 x E1) LIC-T155 (1 x ch-STM-1) LIC-T16 (16 x E1) Line Interface Card 2.5.1...
The LIC is not functioning normally. Green The LIC is functioning normally. STM1/OC3 All interfaces are disabled. STM1/OC3 An STM-1 alarm is present. One or more interfaces are enabled and STM1/OC3 Green there are no STM-1 alarms. Ceragon Proprietary and Confidential Page 24 of 101...
Installation Guide Power Distribution Card (PDC) Evolution IP-20LH receives an external supply of 48V current via one or two Power Distribution Cards (PDCs). The PDC or PDCs distribute the power via the backplane to all the modules in the chassis. Each module receives the 48V input and regulates it down to the operating voltage required by that module.
Page 26
-38V, has returned to at least -40V or higher. Note: If the power is below -38V, the power supply to the TCC is automatically shut down. Ceragon Proprietary and Confidential Page 26 of 101...
The fan speed increases and decreases in response to the temperature inside the chassis. When the temperature rises, the fan speed increases, and when the temperature decreases, the fan speed decreases. The fan speed never decreases below a minimum level regardless of temperature. Ceragon Proprietary and Confidential Page 27 of 101...
Installation Guide Filter Tray Overview A filter is offered as optional equipment. If a filter tray is not ordered, the chassis is equipped with a blank filter slot cover. Filter Tray Detailed View Ceragon Proprietary and Confidential Page 28 of 101...
The Evolution XCVR is a high transmit power transceiver designed for long haul applications with multiple carrier traffic. Ceragon’s patented power amplifier technology enables the XCVR to deliver high transmit power with low power consumption. The Evolution XCVR supports Space Diversity by means of IF Combining.
Installation Guide Preparing for Installation This section provides instructions for transporting, inspecting, and unpacking the equipment for an Evolution IP-20LH system prior to installation. Transportation/Storage The equipment cases are prepared for shipment by air, truck, railway and sea, suitable for handling by forklift trucks and slings. The cargo must be kept dry during transport and storage.
To avoid malfunctioning or personnel injuries, equipment or accessories/kits/plug-in unit installation, requires qualified and trained personnel. Changes or modifications not expressly approved by Ceragon Networks could void the user's authority to operate the equipment Where special cables, shields, adapters and grounding kits are supplied or described in this manual, these items must be used, to comply with the relevant regulations.
Evolution® IP-20LH Installation Guide Ensuring Proper Clearance for Air Flow around the IDU The Evolution IP-20LH fans draw air into the left side of the chassis, and push the air through the chassis and out the right side. IP-20LH Air Flow...
Mounting the IDU Chassis in the Rack This procedure is for both 1RU and 2RU chassis. Note that there are two possible ways to install an Evolution IP-20LH chassis: Standard Mount – The front of the chassis is flush with the front of the rack.
Page 35
Evolution® IP-20LH Installation Guide 2RU IDU Chassis in Rack - Front Mount 1RU IDU Chassis in Rack - Standard Mount Ceragon Proprietary and Confidential Page 35 of 101...
The same procedure is performed for the bracket at the opposite side of the chassis. Remove the four screws that hold the bracket to the chassis. Ceragon Proprietary and Confidential Page 36 of 101...
Page 37
Evolution® IP-20LH Installation Guide Remove the bracket. Align the bracket with the holes in the center of the chassis. Replace all four screws. Ceragon Proprietary and Confidential Page 37 of 101...
Page 38
Evolution® IP-20LH Installation Guide Retighten the screws in the new position. Ceragon Proprietary and Confidential Page 38 of 101...
The size of the grounding wire must be at least: For 2U chassis: 12 AWG For 1U chassis: 18 AWG 1RU Chassis Grounding Ceragon Proprietary and Confidential Page 39 of 101...
Page 40
Evolution® IP-20LH Installation Guide 2RU Chassis Grounding Ceragon Proprietary and Confidential Page 40 of 101...
10 Carefully insert the new chassis into the rack. 11 Fasten the four screws. 12 Reconnect the chassis grounding cable. 13 Re-insert all cards. Tighten the captive screws manually. 14 Reconnect the front cables. 15 Reconnect the power cable(s). Ceragon Proprietary and Confidential Page 41 of 101...
On the rear side of the chassis, place the IVM in front of the backplane and secure it using the two screws supplied with the IVM bracket. Installing an IVM, 1RU Installing an IVM, 2RU Ceragon Proprietary and Confidential Page 42 of 101...
1 Loosen the two screws that secure the IVM in its place and gently pull out the IVM. Replacing an IVM, 1RU Replacing an IVM, 2RU 2 Install the new IVM, as described in Installing an IVM on page 42. Ceragon Proprietary and Confidential Page 43 of 101...
2 Before installing the TCC, insert the SD card into its socket on the upper left side of the TCC. Make sure the orientation of the SD card is correct, as shown in the figure below Ceragon Proprietary and Confidential Page 44 of 101...
Page 45
When the SD card is inserted properly, it should click into place. The figure below shows an SD card properly inserted in its socket on the TCC. SD Card Inserted in a TCC Ceragon Proprietary and Confidential Page 45 of 101...
TCC to enter the internal connectors without the use of excessive force. Make sure that the card ejectors lock in the correct position. Fasten the two captive screws manually. Remove the SFP caps from the TCC. Ceragon Proprietary and Confidential Page 46 of 101...
Before replacing a TCC, you must make sure to back up the system confirmation. After installing the new TCC, you should restore the backed up configuration. For instructions, refer to the Evolution IP-20LH User Guide, DOC-00043450. Remove the SD card. Afterwards,...
Page 48
Evolution® IP-20LH Installation Guide Re-insert the SD card that you removed from the old TCC. Ceragon Proprietary and Confidential Page 48 of 101...
Make sure that the card ejectors lock in the correct position. Fasten the two captive screws manually. Ceragon Proprietary and Confidential Page 49 of 101...
A screwdriver may be used if necessary to unscrew the screws. Release the card from the backplane connectors by means of the card ejectors. Carefully remove the card from the chassis by pulling the screws. Ceragon Proprietary and Confidential Page 50 of 101...
Page 51
Evolution® IP-20LH Installation Guide Ceragon Proprietary and Confidential Page 51 of 101...
Fasten the two captive screws manually. Connect the power cable, as described in Connecting the Power Cable on page 82. Ceragon Proprietary and Confidential Page 52 of 101...
Carefully slide the PDC out of the chassis by pulling the screws. Install the new PDC, as described in Installing a PDC on page 52. Ceragon Proprietary and Confidential Page 53 of 101...
Ensure that the drawer enters the guides inside the chassis, and gently press the card to enter the internal connectors without the use of excessive force. Fasten the two captive screws manually. Ceragon Proprietary and Confidential Page 54 of 101...
Carefully remove the drawer from the chassis by pulling the screws. Install the new fans drawer, as described in Installing the Fans Drawer on page 54. Ceragon Proprietary and Confidential Page 55 of 101...
Follow the procedure below to install the filter unit or to remove the filter foam. Installing the Filter Unit 5.5.1 Insert the filter foam in the filter tray. Ceragon Proprietary and Confidential Page 56 of 101...
Page 57
Evolution® IP-20LH Installation Guide Slide the filter tray into the filter slot in the chassis. Fasten the captive screw manually. Ceragon Proprietary and Confidential Page 57 of 101...
Removing the Filter Foam 5.5.2 The filter tray is secured to the chassis by means of a captive screw (no ejectors). Unscrew the captive screw. Remove the filter tray by pulling the captive screw. Ceragon Proprietary and Confidential Page 58 of 101...
Page 59
Evolution® IP-20LH Installation Guide Remove the filter foam from the filter tray. Ceragon Proprietary and Confidential Page 59 of 101...
1 Slide the XCVR on to the mounting plate using the two guide pins to position it. Note: Make sure to mate the connectors on the back of the XCVR correctly with the sockets on the mounting plate. Ceragon Proprietary and Confidential Page 60 of 101...
Page 61
Mating the connectors of the XCVR with the sockets on the mounting plate XCVR Mounted 2 Secure the XCVR to the mounting plate by tightening the four screws evenly, until the unthreaded part of the screws are seated towards the plate. XCVR Screws Ceragon Proprietary and Confidential Page 61 of 101...
Page 62
Earth Jumper 6 Using the IDU earthing cable, part number UWML6760, connect the earthing terminal at the top right corner of the IDU chassis to the earth terminal block. IDU Chassis Earthing Cable Ceragon Proprietary and Confidential Page 62 of 101...
Page 63
9 Connect the IDU power cable, part number CBL-PWR-OE-OE-16A-5M. Connect the bared ends to the outputs of fuse number 1 and the power cable connector to the power input socket of the PDC in the IDU chassis. IDU Power Cable Ceragon Proprietary and Confidential Page 63 of 101...
Page 64
Single IDU – Single Power Feed 10 If the PDC has a dual power feed, connect another IDU power cable between fuse number 11 and the power input socket. Single IDU – Dual Power Feed Ceragon Proprietary and Confidential Page 64 of 101...
Page 65
Two IDUs – Dual Power Feed 13 Using the optional power cable, part number AWZP36, connect the inputs of fuse number 1 to a 48 VDC power source. Single Power Source – Single IDU Ceragon Proprietary and Confidential Page 65 of 101...
XCVR - "Dir. No" and "Channel No" are used for identification of RMC-E card in the IDU chassis and XCVR devices (see the cable marking and channel identification map). XCVR Label Ceragon Proprietary and Confidential Page 66 of 101...
Page 67
There are three different types of XCVR-IDU cable. Channel Identification Map - This map is used for identification of the slot number of the RMC-E in the IDU chassis versus Channel No. and Direction Channel Identification Map Ceragon Proprietary and Confidential Page 67 of 101...
As the weight of 2 or 4 XCVRs is significant, use a hoist to mount the devices. Note: Do not use the XCVR handles to hoist the assembled branching box with XCVRs. Ceragon Proprietary and Confidential Page 68 of 101...
Use the pole mount kit, part number ABZ6859, to mount the branching box on the mounting pole, as follows: 1 Mount the support clamp on the pole to prevent the branching box from sliding downwards after installation. Pole Support Clamp Ceragon Proprietary and Confidential Page 69 of 101...
Page 70
For a pole of 75 mm diameter, use the 75 mm U-shaped clamps and for a 115 mm pole, use the 115 mm U-shaped clamps. The mounting handles have two sets of holes for this purpose. 75 mm and 115 mm Holes Ceragon Proprietary and Confidential Page 70 of 101...
Page 71
The second waveguide is for use when installing dual polarized antennas. ii Remove the waveguide flange cover plate on the back of the antenna. Removing Waveguide Flange Cover on Antenna iii Apply gasket grease to the four gaskets. Ceragon Proprietary and Confidential Page 71 of 101...
Page 72
(Dual Pol. / Space Div. / Multiple Dir.). 8 Install earthing cables, as follows: Connect an earthing cable, part number UWML6505, to the earthing terminal on the bottom of each XCVR. Ceragon Proprietary and Confidential Page 72 of 101...
Page 73
Branching Box Earthing Cable Note: Earthing cables must be at least 10mm2 (AWG7). The M5 earth terminal screws (with washers) must be properly tightened (torque 6 Nm). Earthing Cables Installed Ceragon Proprietary and Confidential Page 73 of 101...
Page 74
Thread a neoprene sleeve over the cable connectors at the XCVR side. Neoprene Sleeve iii Connect the XCVR-IDU cable to the socket, slide the neoprene sleeve over the bushing, and secure it with a cable tie. Connect XCVR-IDU Cable Ceragon Proprietary and Confidential Page 74 of 101...
Page 75
3 meters on the two polarizations. IDU-XCVR Cables Installed 10 Tie all the cables to the pole neatly with cable ties every half meter. Tie Cables to Pole with Cable Ties Ceragon Proprietary and Confidential Page 75 of 101...
Page 76
50 meters. The earthing cable pin is inserted vertically into the earth to improve lightning protection. Typical Earthing Kit Installation on XCVR-IDU Cable To Earth (optional) To IDU To Earth Ceragon Proprietary and Confidential Page 76 of 101...
Remove the XCVR-IDU cable by unscrewing the plug from the XCVR connector. ii Unscrew the four bolts securing the XCVR to the rack mounting plate. iii Remove the XCVR from the equipment rack by gently pulling it towards you. XCVR Removed Ceragon Proprietary and Confidential Page 77 of 101...
Page 78
Do not drop screws or washers into the open waveguide flanges. 5 Mount the new filters. Each filter is marked with a channel frequency. Make sure that the filters are mounted according to the frequency plan. Ceragon Proprietary and Confidential Page 78 of 101...
Page 79
7 Mount the XCVR interface plate by securing it to the support bar with two screws (mounted from the rear side of the interface plate). Mounting XCVR Interface Plate 8 Connect coax cables between the filters and the interface plate. Connecting Coax Cables Ceragon Proprietary and Confidential Page 79 of 101...
Page 80
12 Mount two new guide pins for the new XCVR. XCVR-Guide Pins 13 Mount the XCVR devices and secure their screws. 14 Connect the XCVR-IDU cables. 15 Power up the system by raising fuses M1 and M2. Ceragon Proprietary and Confidential Page 80 of 101...
Blank Panel TCC Blank Panel PDC Blank Panel RMC/LIC To install a blank panel, insert the appropriate panel into the slot and secure the panel using captive screws. Installing a Blank Panel Ceragon Proprietary and Confidential Page 81 of 101...
1RU units can use a single-feed or dual-feed PDC. The power cable connector is included with the PDC. The following power cables are available for use with a 1RU IP-20LH unit: Marketing Description Ceragon Part Number Marketing Model WA-0567-0 CBL-PWR-OE-OE-16A-2.2m Power cable Open-end/Open-end, 16A, 2.2m...
2 Plug the power connector into the PDC and tighten the two captive screws on the sides of the connector to secure the connector. Connecting the Power Cable in a 2RU Chassis Ceragon Proprietary and Confidential Page 83 of 101...
6. Plug the connector into the PDC and tighten the two screws on the sides of the connector to secure the connector. Connecting the Power Cable in a 2RU Chassis – Single-Feed PDC Ceragon Proprietary and Confidential Page 84 of 101...
Page 85
Evolution® IP-20LH Installation Guide Connecting the Power Cable in a 2RU Chassis – Dual-Feed PDC Ceragon Proprietary and Confidential Page 85 of 101...
16A for 1RU and 32Amp for 2RU. Power supply grounding should be in accordance with the following figures: Power Supply Grounding – 1RU Chassis with Dual-Feed PDU Power Supply Grounding – 1RU Chassis with Single-Feed PDU Ceragon Proprietary and Confidential Page 86 of 101...
Page 87
Evolution® IP-20LH Installation Guide Power Supply Grounding – 2RU Chassis Ceragon Proprietary and Confidential Page 87 of 101...
IP-20LH unit and lists the configuration steps that should be performed in order to enable basic radio connectivity. For detailed configuration instructions, refer to the Evolution IP-20LH User Guide, DOC-00043450. Establishing a Connection You can connect to the IP-20LH unit via a Serial or a LAN connection.
2 Click Change adapter settings. 3 Select Local Area Connection> Properties> Internet Protocol Version 4 (TCP/IP). IP address: 192.168.1.10 Subnet mask 255.255.255.0 No default gateway 4 Press OK to apply the settings. Ceragon Proprietary and Confidential Page 89 of 101...
1 Open an Internet browser (Internet Explorer or Mozilla Firefox). 2 Type in the default IP address "192.168.1.1" in the Address Bar. Login Window 3 Enter the following values: User Name: admin Password: admin 4 Click Apply. Ceragon Proprietary and Confidential Page 90 of 101...
In addition to setting the IP addresses, the following configuration steps should be performed in order to establish basic connectivity. For a detailed description of these procedures, refer to the Evolution IP-20LH User Guide, DOC-00043450. ...
An LIC-X-E4-Opt (4x GE) contains 1 GbE combo interface and 3 GbE optical (SFP) interfaces. The pin-out scheme for the GbE RJ-45 interfaces is the same as for the GbE RJ- 45 interfaces on the TCC. Ceragon Proprietary and Confidential Page 94 of 101...
TWISTED PAIR OUT - RING9 OUT - TIP10 Ch10 Tx TWISTED PAIR OUT - RING10 OUT - TIP11 Ch11 Tx TWISTED PAIR OUT - RING11 OUT - TIP12 Ch12 Tx TWISTED PAIR Ceragon Proprietary and Confidential Page 95 of 101...
Page 96
TWISTED PAIR IN - RING9 IN - TIP10 Ch10 Rx TWISTED PAIR IN - RING10 IN - TIP11 Ch11 Rx TWISTED PAIR IN - RING11 IN - TIP12 Ch12 Rx TWISTED PAIR Ceragon Proprietary and Confidential Page 96 of 101...
The 1 x ch-STM-1 interface uses an optical SFP connector. 1 x ch-STM-1 Connector Synchronization Interface The RJ-45 synchronization interface on the LIC-T155 has the same pin-out as the RJ-45 synchronization interface on the LIC-T16. Ceragon Proprietary and Confidential Page 98 of 101...
For temperatures below 0C, the equipment must be switched on for at least 10 minutes in order to operate according to the specifications. Humidity: 5%RH to 100%RH Ceragon Proprietary and Confidential Page 99 of 101...
Indoor XCVR Shelf Width: 481 mm Depth: 231 mm 2 channel system: 45 kg 4 channel system: 60 kg Long Haul Indoor Terminals 6 channel system: 77 kg 8 channel system: 106 kg Ceragon Proprietary and Confidential Page 100 of 101...
30W max (6W typical at 25°C) Kinetic energy Fan – 1RU Chassis 6W max (4W typical at 25°C) Kinetic energy Evolution XCVR 55-64W XCVR only Evolution XCVR – Space Diversity 58-67W XCVR only Ceragon Proprietary and Confidential Page 101 of 101...