    Contents Explanation of Symbols General Health & Safety Guidance 4 - 9 Additional Health & Safety for High Filtration Dust Extractors 10 - 12 Record Power Guarantee 13 - 14 2.5” Inlet Unpacking Setting up Your Vacuum Motor Important Filtration Parts &...
  • Page 3: Explanation Of Symbols

    Explanation of Symbols The symbols and their meanings shown below may be used throughout this manual. Please ensure that you take the appropriate action wherever the warnings are used. Mandatory Instructions Warnings Read and fully understand Indicates a risk of severe the instruction manual before personal injury or damage to the attempting to use the machine.
  • Page 4: General Health & Safety Guidance

    General Health & Safety Guidance Ensure that you carefully read and fully understand the instructions in this manual before assembly, installation and use of this product. Keep these instructions in a safe place for future reference. WARNING: for your own safety, do not attempt to operate this machine until it is completely assembled and installed according to these instructions.
  • Page 5 General Health & Safety Guidance 5. Take care when moving or positioning the machine • Some machines can be very heavy. Ensure the floor of the area in which the machine is to be used is capable of supporting the machine. •...
  • Page 6 General Health & Safety Guidance 10. Keep the work area clear • Working clearances can be thought of as the distances between machines and obstacles that allow safe operation of every machine without limitation. Consider existing and anticipated machine needs, size of material to be processed through each machine and space for auxiliary stands and/or work tables.
  • Page 7 General Health & Safety Guidance are not obstructing high-traffic areas. Observe local electrical guidelines for proper installation of new lighting, power outlets, or circuits. • The machine must be connected to an earthed power supply. • The power supply must be equipped with a circuit breaker that provides short circuit, overload and earth leakage protection.
  • Page 8 General Health & Safety Guidance • Use extra supports (roller support stands etc.) for any work pieces large enough to tip when not held down to the table top. • Do not use another person as a substitute for a table extension, or as additional support for a work piece that is longer or wider than the basic table, or to help feed, support, or pull the work piece.
  • Page 9 General Health & Safety Guidance • Do not use compressed air to clean the machine. Always use a brush to dislodge dust in places that are awkward to reach and a dust extractor to collect the waste. • Inspect electric cables periodically and, if damaged, have them replaced by an authorised service facility or qualified electrician.
  • Page 10 Additional Health & Safety for High Filtration Dust Extractors 1. Safe Operation • Floor standing dust extractors should be positioned on a level floor. Ensure that there is no debris between the base of the extractor and the floor. • Wall mounted dust extractors, or those used with an optional wall mounting bracket, should be fixed to a solid block or brick wall using suitable fixings that will withstand the weight of the machine.
  • Page 11: Additional Health & Safety For High Filtration Dust Extractors

    Additional Health & Safety for High Filtration Dust Extractors 4. Whilst using the dust extractor: • Do not completely cover the end of the extraction hose as the machine may be pulled in the direction of the hose. • Do not attempt to remove the lid assembly from the drum body. •...
  • Page 12 Additional Health & Safety for High Filtration Dust Extractors • Do not switch the head unit ‘ON’ unless it is attached to the collection drum or body unit. The centrifugal force created by the motor will cause the head to rotate very quickly and can cause serious personal injury.
  • Page 13: Record Power Guarantee

    Record Power Guarantee “Products” means the Products sold by Record Power subject to these terms and conditions; “Record Power” is Record Power Limited, whose company registration number is 4804158 and registered office address is Centenary House, 11 Midland Way, Barlborough Links, Chesterfield, Derbyshire, S43 4XA and sells through a network of Authorised Dealers;...
  • Page 14 Record Power Guarantee Claims Procedure In the first instance please contact the Authorised Dealer who supplied the Product to you. In our experience many initial problems with machines that are thought to be due to faulty parts are actually solved by correct setting up or adjustment of the machines. A good Authorised Dealer should be able to resolve the majority of these issues much more quickly than processing a claim under the guarantee.
  • Page 15: Inlet

    2.5” Inlet Unpacking The GV336 vacuum is shipped in one carton. Additional to the machine in the carton will be ( if ordered ) either a standard tool kit or full tools kit. 1 x 2.5” Standard Tool Kit (includes 1 x 2.5” diameter x 2.5m Long Flexible Hose, 1 x Extension Tubes (pair), 1 x Utility Nozzle (square tool) and 1x Crevice Tool.
  • Page 16: Important Filtration

    Camvac machines are equipped with full 3-stage filtration to 0.5 microns. Efficiency of the ust is present on the filter bag or in the absence of any visible at regular intervals.
  • Page 17: Parts & Accessories

    Accessories and replacement parts are available upon request. Hose Length & Accessories Camvac do not advise the increase in length of inlet hose to more than 2 times the standard hose length (2.5 metres). Camvac machines are used in a wide variety of applications and guidance cannot be given which covers every eventuality.
  • Page 18: 4" Inlet

    Urethane vacuum hose, it should be noted that Urethane hose has a life expectancy of 5 to 10 times the life of conventional PVC hoses. Any of the Camvac machines supplied with a 4” inlet can be successfully reduced down to accept a 2.5” tool kit.
  • Page 19: Important Filtration

    This is particularly important when fine materials such as flour, soot, fine wood dust etc. are being handled. The motor must not be started without checking the cloth and paper filter bags are in position and clean. Replacements are available from Camvac. Vacuum head removal...
  • Page 20: Parts & Accessories

    Accessories and replacement parts are available upon request. Hose Length & Accessories Camvac do not advise the increase in length of inlet hose to more than 2 times the standard hose length (2.5 metres). Camvac machines are used in a wide variety of applications and guidance cannot be given which covers every eventuality.
  • Page 21: Vacuum Filter Maintenance

    (Size depends on CamVac Model) (Size depends on CamVac Model) To keep your Camvac working as good as new for years to come, To keep your Camvac working as good as new for years to come, To keep your Camvac working as good as new for years to come,...
  • Page 22: Electrical Connection & Wiring Diagram

    Electrical Connection & Wiring Diagrams Machines supplied for use in the UK are fitted with a 3 pin plug conforming to BS1363, fitted with a fuse conforming to BS1362 and appropriate to the current rating of the machine. Machines supplied for use in other countries within the European Union are fitted with a 2 pin Schuko plug conforming to CEE 7/7.
  • Page 23 Electrical Connection & Wiring Diagrams 230 V machines will be fitted with a blue 3 pin connector. The wiring for this type of this connector will be the same as shown above. 400 V, 3 phase machines will be fitted with a red 4 or 5 pin connector. The wiring for this type of connector is as shown below: 400 V (3 phase) Brown:...
  • Page 24 Electrical Connection & Wiring Diagrams All Single Motor Machines Double Pole Twin Motor Machines Tel: 01246 571 020 Fax: 01246 571 030 Email: sales@recordpower.co.uk...
  • Page 25: Eu Certificate Of Conformity

    Record Power Ltd, Centenary House, 11 Midland Way, Barlborough Links, Chesterfield, Derbyshire S43 4XA. declares that the machinery described:- 1. Type: High Filtration Dust Extractor 2. Model No: GV336 2.5” & 4” Inlet 3. Serial No ................. Conforms with the following directives:- Machinery Directive: 2006/42/EC...