5 Technical Data
5.1 General
Mounting
Material
W x L x H
Protective class
Operating temperature
Storage temperature
Humidity
5.2 Wireless M-Bus Interface
Standard
Transmit mode
Encryption
Transmit interval
5.3 Power Supply
Battery
Batterie lifetime
5.4 Sensors
Temperature range
Temperature accuracy
Temperature resolution
Humidity range
Humidity accuracy
Humidity resolution
5.5 Ordering Information
RelAir ICS
Wireless M-Bus Indoor Climate Sensor (Temperature + Humidity)
User Manual RelAir ICS ·03/2019 · VERSION 1.0
Wall mounting or mounting on an in-wall box (60 mm)
ABS, white
(80 x 80 x 25) mm
IP40
-10°C to +55°C
-20 to +70°C
10% to 80% (not condensing)
EN13757-4 and EN13757-3, compatible to OMS
S1 or T1 (unidirectional) / Frame Format A
Mode 0 (not encrypted) or Mode 5
Configurable by DIP switches: 1 min, 5 min, 10 min, 15 min
2 replaceable AA alkaline cells (industrial grade) in scope of supply
Transmit interval 15 min. / up to 10 years
-10°C to +55°C
± 0.3 °C
0.1 °C
20% RH to 80% RH
± 2% RH
0.1% RH
RelAir ICS
9