SETTINGS 2 Explanation

GAS METER CALIBRATION
Rev: 07 05-19
Select [GAS METER CALIBRATION] option.
 Fans start operating at max speed and the gas valve will open.
 Turn all appliances on and set gas
to maximum.
 When all appliances are ready -
press OK.
 Calibration can take up to 3
minutes.
 Whilst calibrating, the screen
opposite will be displayed
The Merlin 3000S will then confirm successful calibration
If the system encounters a problem – the screen may display the following;
Too many pulses
The 3000S will automatically increase the calibration time when it receives
less than 12 pulses within 5 seconds and decreases calibration time when
receiving more than 999 pulses within 5 seconds.
Calibration is possible only when the 3000S receives 12 to 998 pulses within 2
to 60 seconds.
The system will measure three times the number of pulses and save an
average value.
The calibration time will have an influence on the fan speed response time in
relation to CO
value and duct temperature
2